Equipment information
Associated Research Incorporated 3030D Test Set
Manufacturer:
Image 1 of 1
If you have any other photos or manuals for the
Associated Research Incorporated 3030D you can upload the files here .
Model:
3030D
Date:
2000
Category:
Group:
Description:
GROUND BOND TESTER
Information
KEY FEATURES & BENEFITS OF HYAMP in
1. All parameters for the setups can be adjusted through a
simple menu driven program by using front panel keys.
The easy to follow setup screens ensure that the operator
correctly sets up all test parameters.
2. Tamper proof front panel controls.
This makes it possible to limit user access to the setup
screens.
3. MilJiohm offset capability.
rThe milliohm off set function allows the use of longer test
leads and test fixtures without compromising the test results.
4. Storage of up to 5 different test programs.
A real benefit for manufacturers that test different
products. - This makes it possible to store all the various
test parameters required and quickly recall them for each of
the different products that needs to be tested
5. Versatile PLC control.
Interconnection.of the HYAMP jr. and the Hypot II makes
these two instruments a true semi-automated test system. The
test system can be configured to test Ground Bond first and
then advance to the Dielectric Withstand test and Insulation
Resistance tests.
6. Line and load regulation.
This system maintains the output voltage to within 1% from
no load to full load and over the line voltage range to
ensure that test results remain consistent and within safety
agency requirements.
7. User selectable output voltage frequencies of 50 or 60 hertz.
HYAMP jr. was designed for the global market This feature
makes it simple for the user to select the output frequency
in the Ground Bond mode so that products can be tested at
the same frequency they will be used at
8. Adjustable output current and milliohm trip ranges.
This capability makes the HYAMP jr. versatile enough to meet
all safety agency specifications for ground bond test
requirements.
9. Front panel LCD displays test parameters and results.
A front panel LCD allows the operator to monitor the test
The display holds the results after a test item failure so
that the operator can easily review the test results.
10. PLC remote inputs and outputs.
The standard 9 pin interfaces provide outputs for Pass,
Fail, and Test in Process,
Start Out and Reset Out. Inputs include Test, Reset, and
Withstand Processing.
11. Test indicator.
An LED located directly over the high current terminal
clearly indicates when high current is active to provide
maximum operator safety.
12. Withstand processing indicator.
The front panel display indicates when the high voltage from
the Hypot II is being applied to the item under test for
greater operator safety.
13. Software calibration control.
HYAMP jr. is calibrated through the front panel keypad. All
calibration information is stored in non-volatile memory.
This allows HYAMP jr. to be completely calibrated without
removing any covers and exposing the technician to hazardous
voltages.
Manual Type:
Service and User Manual
Pages:
51
Size:
1.83 Mbytes (1916072 Bytes)
Language:
english
Revision:
1.05
Manual-ID:
37952
Date:
2000 11 17
Quality:
Scanned document, all readable.
Upload date:
2017 10 21
MD5:
301372b7b1e5df5c9a441459b289b8fb
Downloads:
486
Information
SECTION I OPERATORS
MANUAL.,, ... 1
SAFETY ... 2
INTRODUCTION ... 5
SPECIFICATIONS ... 8
CONTROLS ... 12
INSTALLATION ... 15
QUICK
START ... 18
OPERATION ... 22
OPTIONS ... 32
SECTION II SERVICE
MANUAL ... 35
CALIBRATION ... 36
PARTS
LIST ... 38
SCHEMATICS ... 39