Equipment information

LeCroy 9314C Oscilloscope
Manufacturer:
Model:
9314C
Date:
1994
Category:
Group:
Description:
Digital Storage Oscilloscope

Information

The 9310A family forms a range of ideal general-purpose digital oscilloscopes. They capture single-shot events at up to 100 MSamples/s, and repetitive signals at 10 GSamples/s. Record lengths up to 1M points provide high-quality horizontal resolution, and allow fast digitizing of long-duration events. Memories can be segmented, for minimum dead time between acquisitions. Live waveforms may be viewed simultaneously with up to 3 expansions, showing all of the signal detail. Expansions are shown as highlights on the main trace. The LeCroy ProBus™ intelligent Probe system allows automatic sensing of the Probe type. For LeCroy's active FET probes it also provides variable offset at the Probe tip; offset and coupling are controlled from the scope front panel. SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest. A comprehensive range of signal processing functions, on live or stored waveforms, allows waveform manipulation without destroying the underlying data. The 9310A family features the proven user-interface of LeCroy's portable scope family. A bright, high-resolution 9" CRT allows optimum waveform viewing under any conditions. Menus and text are arranged around the graticules -they never overwrite the waveforms. Each of the main control functions has a dedicated single knob, to keep the scope’s performance at your fingertips. DOS compatible floppy disk and memory card options store waveforms and test setups, and make transferring data to a PC easier than ever before. Hardcopies may be made on GPIB, RS-232-C or Centronics printers or plotters. An optional internal printer is also available. Optional packages provide extensive Waveform Processing including FFT and Enhanced Resolution to 11 bits.

show more

User Manual
Manual Type:
User Manual
Pages:
275
Size:
5.49 Mbytes (5758060 Bytes)
Language:
english
Revision:
A
Manual-ID:
93XXC-OM-E
Date:
1998 01 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2021 01 10
MD5:
6c2570da8f4b0b75a9fe55b62240b2b7
Downloads:
1499

Information

Chapter 1 — Read This First! Product and Client Care ... 1–1 Chapter 2 — Instrument Architecture General Designed Capabilities ... 2–1 Block Diagrams ... 2–4 Chapter 3 — Installation and Safety Installation for Safe and Efficient Operation ... 3–1 Chapter 4 — Introduction to the Controls The Front Panel ... 4–1 The Main Controls ... 4–3 Choosing and Navigating in Menus ... 4–4 System Setup and Menu Controls ... 4–6 Screen Topography ... 4–8 Chapter 5 — CHANNELS, Coupling and Probes Channel Controls ... 5–1 Coupling ... 5–3 Probes and Probe Calibration ... 5–4 Chapter 6 — TIMEBASE + TRIGGER TIMEBASE + TRIGGER Controls ... 6–1 Chapter 7 — Timebase Modes and Setup Timebase Sampling Modes ... 7–1 Timebase Setup ... 7–5 Chapter 8 — Triggers and When to Use Them Choosing the Right Trigger ... 8–1 Edge or SMART? ... 8–2 Edge Trigger ... 8–3 TRIGGER SETUP: Edge ... 8–9 SMART Triggers ... 8–10 TRIGGER SETUP: SMART ... 8–29 Chapter 9 — ZOOM + MATH Zoom and Math Controls ... .9–1 Chapter 10 —Zoom, Mathematics and Math Setup Zooming for Precise Waveform Measurements ... 10–1 Math Functions and Options ... 10–2 Using Waveform Mathematics ... 10–5 Configuring for Zoom and Math ... 10–6 Setting Up FFT Span and Resolution ... 10–17 Chapter 11 — Display Chapter 12 — UTILITIES Setting Up the Display ... 11–1 Printing, Storing, Using Special Modes ... 12–1 Hardcopy Setup ... 12–2 Time/Date Setup ... 12–4 GPIB/RS232 Setup ... 12–5 Mass Storage Utilities ... 12–7 Special Modes ... 12–19 CAL BNC Setup ... 12–21 Chapter 13 —WAVEFORM STORE & RECALL Waveform Store ... 13–1 Waveform Recall ... 13–4 Chapter 14 — CURSORS/MEASURE & Parameters Cursors: Tools for Measuring Signal Values ... 14–1 Parameters: Automatic Measurements ... 14–4 Pass/Fail Testing ... 14–13 Chapter 15 — PANEL SETUPS Saving and Recalling Panel Setups ... 15–1 Chapter 16 — SHOW STATUS The Complete Picture — Summarized ... 16–1 Appendix A — Specifications Appendix B — Enhanced Resolution Appendix C — Fast Fourier Analysis (FFT) Appendix D — Parameter Measurement Appendix E — ASCII-Stored Files

show more

User Manual
Manual Type:
User Manual
Pages:
258
Size:
4.24 Mbytes (4450391 Bytes)
Language:
english
Revision:
A
Manual-ID:
93XXC-OM-E
Date:
1998 01 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2021 01 06
MD5:
983846db70dcc29334cd96888a6627a0
Downloads:
1304

Information

Chapter 1 — Read This First! Product and Client Care ... 1–1 Chapter 2 — Instrument Architecture General Designed Capabilities ... 2–1 Block Diagrams ... 2–4 Chapter 3 — Installation and Safety Installation for Safe and Efficient Operation ... 3–1 Chapter 4 — Introduction to the Controls The Front Panel ... 4–1 The Main Controls ... 4–3 Choosing and Navigating in Menus ... 4–4 System Setup and Menu Controls ... 4–6 Screen Topography ... 4–8 Chapter 5 — CHANNELS, Coupling and Probes Channel Controls ... 5–1 Coupling ... 5–3 Probes and Probe Calibration ... 5–4 Chapter 6 — TIMEBASE + TRIGGER TIMEBASE + TRIGGER Controls ... 6–1 Chapter 7 — Timebase Modes and Setup Timebase Sampling Modes ... 7–1 Timebase Setup ... Chapter 8 — Triggers and When to Use Them Choosing the Right Trigger ... 8–1 Edge or SMART? ... 8–2 Edge Trigger ... 8–3 TRIGGER SETUP: Edge ... 8–9 SMART Triggers ... 8–10 TRIGGER SETUP: SMART ... 8–29 Chapter 9 — ZOOM + MATH Zoom and Math Controls ... .9–1 Chapter 10 —Zoom, Mathematics and Math Setup Zooming for Precise Waveform Measurements ... 10–1 Math Functions and Options ... 10–2 Using Waveform Mathematics ... 10–5 Configuring for Zoom and Math ... 10–6 Setting Up FFT Span and Resolution ... 10–17 Chapter 11 — Display Chapter 12 — UTILITIES Setting Up the Display ... 11–1 Printing, Storing, Using Special Modes ... 12–1 Hardcopy Setup ... 12–2 Time/Date Setup ... 12–4 GPIB/RS232 Setup ... 12–5 Mass Storage Utilities ... 12–7 Special Modes ... 12–19 CAL BNC Setup ... 12–21 Chapter 13 —WAVEFORM STORE & RECALL Waveform Store ... 13–1 Waveform Recall ... 13–4 Chapter 14 — CURSORS/MEASURE & Parameters Cursors: Tools for Measuring Signal Values ... 14–1 Parameters: Automatic Measurements ... 14–4 Pass/Fail Testing ... 14–13 Chapter 15 — PANEL SETUPS Saving and Recalling Panel Setups ... 15–1 Chapter 16 — SHOW STATUS The Complete Picture — Summarized ... 16–1 Appendix A — Specifications Appendix B — Enhanced Resolution Appendix C — Fast Fourier Analysis (FFT) Appendix D — Parameter Measurement Appendix E — ASCII-Stored Files

show more

Service Manual
Manual Type:
Service Manual
Pages:
428
Size:
10.96 Mbytes (11491922 Bytes)
Language:
english
Revision:
first edition
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
2013 01 26
MD5:
a07fccce52b929acf03bd46b1b11a83d
Downloads:
4957