Informações do equipamento

Good Will LCR-826 LCR Medidor
Fabricante:
Good Will
Modelo: LCR-826
Data:
Categoria: Instrumentos de medição
Grupo: LCR Medidor
Descrição:
Informações:

The precise LCR Meter series are automatic, user programmable instruments that provide high reliability and great precision for measuring a wide variety of impedance parameters. The frequency range of LCR-819/829 covers from 12Hz to 100kHz, LCR-817/827 from 12Hz to 10kHz, LCR-816/826 from 100Hz to 2kHz, and LCR-821 from 12Hz to 200kHz. The basic accuracy is 0.1% for LCR- 827/829/816/826, 0.05% for LCR-817/819/821. The measured results can be displayed on the high quality LCD monitor with decimal points and units. The measured result resolution is five full digits for Inductance (L), Capacitance (C), Resistance (R) and absolute value of impedance (|Z|) [four full digits for Dissipation factor (D), Quality factor (Q), R with C, R with L, 2 digits after decimal dot for phase angle (θ)]. In the meantime, the LCD monitor is also shown the control status and parameters of settings. The keypads are easy for menu programming. The LCR Meters’ test fixture (option) is a method of convenient, reliable, guarded 4-terminal/2 wires connection of radial and axial leaded components to the LCR Meters. Test conditions can be stored and recalled from internal memory that will reduce the setup time for measurement preparing.

Estes manuais estão disponíveis para os equipamentos acima:

Tipo manual: Manual do Usuário GoodWill-9022-Manual-Page-1-Picture
Páginas: 40
Tamanho: 710.70 Kbytes (727758 Bytes)
Língua: Inglês
Revisão:
Manual-ID/número:
Data:
Qualidade: Documento eletrônico, digitalização, bem legível.
Upload de data:
MD5: 5b7be1d872d18f20b2abe2481e9b2779
Downloads: 303 desde 14 Maio 2017
Informações:

1. INTRODUCTION ... 1 2. 3. 4. PRECAUTIONS BEFORE OPERATION ... 2-1.Unpacking the instrument ... 2-2.Checking the Line Voltage ... 2-3.Environment ... 2-4.Equipment Installation and Operation ... PANEL DESCRIPTION ... OPERATION ... 4-1.Connects to DUT ... 4-2.Start-Up ... 4-3.Zeroing ... 4-4.Menu Functions ... 4-5.Measurement Conditions ... 2 2 2 3 3 4 8 8 8 8 11 18 5. SPECIFICATIONS ... 35 6. MESSAGE CODE ... 44 7. MAINTENANCE ... 45 7-1.Cleaning ... 45 7-2.Battery Replacement ... 45 7-3.Recall Calibration ... 46 8. OPTION 1 (BIN Function for LCR-826/827/829 only) ... 48 8-1. BIN Functions for Components Sorting ... 48 8-2. BIN Setting Conditions ... 50 8-3. BIN Range Setting: Component Sorting Range ... 56 9. OPTION 2 ... 9-1.On-line procedure ... 9-2.RS232 VIEWER Software Operation ... 9-3.The Configuration of Cable ...

GoodWill-9022-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics