Informações do equipamento

Philips PM6302 LCR Medidor
Fabricante:
Philips
Modelo: PM6302
Data: 1979
Categoria: Instrumentos de medição
Grupo: LCR Medidor
Descrição: RCL Bridge
Informações:

The RCL-bridge PM 6302 is used to measure ohmic resistors in the range 0.05 £1... 105 Mfi, capacitors in the range 0.5 pF ... 1050 fxF and inductances in the range 0.5 /jH ... 1050 H. When measuring capacitors and inductances also a measuring value of the loss factor D or the quality factor Q is obtained. For the adjusting a vernier with linear indicator scale is used. The unknown measuring value is obtained after the adjusting by multiplying the scale value by the factor of the selected measuring range. The bridge balance is indicated by a moving-coil indicator, which is controlled by an Amplifier with logarithmic gain characteristic, adjusting of the bridge sensitivity being then redundant. Push-buuon SEARCH is used to find quickly the correct measuring range in the searching mode. For measuring electrolytic capacitors an external formation voltage can be supplied. By means of an external adjustable d.c.-voltage it is possible to measure junction-capacitances on varicaps.

Estes manuais estão disponíveis para os equipamentos acima:

Tipo manual: Serviço e Manual do Usuário Philips-8764-Manual-Page-1-Picture
Páginas: 57
Tamanho: 1.87 Mbytes (1963170 Bytes)
Língua: english, german, french
Revisão:
Manual-ID/número: 9499 52 05902
Data: 01 Fevereiro 1979
Qualidade: Documento Scaned, a leitura parcialmente mal, não parcialmente legível.
Upload de data:
MD5: 9c4ed98a23e75eb57a556862990a955b
Downloads: 257 desde 04 Fevereiro 2017
Informações:

1. GENERAL INFORMATION 7 1.1. Introduction 7 1.2. Technical data 7 1.3. Accessories 9 1.4. Description of the block diagram 10 2. DIRECTIONS FOR USE 10 2.1. Installation 10 2.1.1. Safety regulations 10 2.1.2. Controls and sockets 10 2.1.3. Position 11 2.1.4. Connection to the mains 11 2.1.5. Earthing 11 2.2. Operation 11 2.2.1. Switching on the instrument 11 2.2.2. Measuring resistors 11 2.2.3. Measuring capacitors 11 2.2.4. Measuring inductances 12 2.2.5. Measuring with external a.c. voltage supply 13 3. SERVICE DATA 31 3.1. Circuit description 31 3.1.1. Bridge arrangements 31 3.1.1.1 Bridge for R measurement 31 3.1.1.2 Bridge for C measurement 31 3.1.1.3 Bridge for L measurement 32 3.1.2. Zero indicator 32 3.1.2.1 A.c.-d.c. Converter 32 3.1.2.2 Operational Amplifier as a voltage-current inverter 33 3.1.3. Supply voltage Generator 33 3.1.3.1 D.C. voltage supply 33 3.1.3.2 Supply Oscillator 33 3.1.4. Arrangement for the searching range 33 3.1.5. Current supply 34 3.2. Gaining access to parts 34 3.3. Maintenance and service 34 3.4. Survey of adjusting elements and auxiliary equipment 35 3.5. Checking and adjusting 36 3.5.1. General test 36 3.5.2. Adjusting procedures 37 3.5.3. Testing the bridge functions 38 3.6. Parts list 42 3.6.1. Mechanical parts 42 3.6.2. Electrical parts 43

Philips-8764-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics