Equipment information
Wavetek 801 Generator
Manufacturer:
Image 1 of 1
If you have any other photos or manuals for the
Wavetek 801 you can upload the files here .
Model:
801
Date:
Category:
Group:
Description:
50 MHz PULSE GENERATOR
Information
THE MODEL 801
The model 801 is a 50 MHz general purpose laboratory pulse
generator. The instrument gives you full control in primary
pulse triggering and shaping plus simultaneous TTL, ECL, ECL
and sync pulses. The primary pulse output has
controllability in offset and independent rise/faSi
durations, as well as pulse width, pulse delay and a choice
of positive, negative or complementary outputs. The TTL, ECL
and ECL are of fixed levels and rise times that are standard
for use with compatible devices. The primary pulse has
minimum rise and fall times of 7 ns and a maximum of 250 ms.
The output is ±20 volts with 500 source impedance which
provides ±10 volts into a 5012 load. Upper and lower pulse
levels are fuily adjustable through ±20 volts.
External triggering can be set to any point of the rising or
trailing edge of the trigger signal. Single pulses or pulse
pairs may be triggered; pulse width may be trigger
controlled; continuous pulses may be gated and a precise
number of pulses may be triggered for a 'burst' output.
Manual and external triggering is indicated by an LED on the
front panel for rapid visual set of trigger level.
1.2 SPECIFICATIONS
1.2.1 Versatility
Five Simultaneous Pulse Outputs
Fixed level ECL, ECL, TTL and sync pulses and a pulse with
variable amplitude and variable rise/fall times. Pulses
available over a 5 Hz to 50 MHz frequency range (200 ms to
20 ns periods).
Operational Modes
Continuous; Generator oscillates continuously at selected
frequency.
Triggered: Generator quiescent until triggered by external
signal or front control, then generates one pulse.
Gated: As triggered mode, except Generator oscillates for
the duration of the external signal.
Double Pulse: Continuous, trigger and gate, as above, except
two pulses for each period. Space between pulses of
double pulse controlled by delay control. Double pulse at
all outputs except sync.
Manual Type:
Pages:
9
Size:
571.91 Kbytes (585636 Bytes)
Language:
english
Revision:
C
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
2014 11 17
MD5:
760885252cc290b311d92487c5c7118b
Downloads:
1145
Information
Only a few pages from the Instruction manual.
Manual Type:
User Manual
Pages:
26
Size:
957.04 Kbytes (980010 Bytes)
Language:
english
Revision:
P
Manual-ID:
Date:
1984 05 01
Quality:
Scanned document, all readable.
Upload date:
2018 08 15
MD5:
7c57747d309d96cc526cdced0ac091d3
Downloads:
555