Equipment information
Keithley 197A Digital multimeter
Manufacturer:

Image 1 of 1
If you have any other photos or manuals for the
Keithley 197A you can upload the files here .
Model:
197A
Date:
1990
Category:
Group:
Description:
Information
The Model 197A is a six function, 5-1/2 digit resolution
autoranging Digital multimeter with a ±220,000 count LCD
(Liquid Crystal Display). This A/D range is greater than the
normal ±199,999 count A/D used in many 5-1 /2 digit DMMs.
The 5-1 /2 digit resolution allows the Model 197A to measure
DC voltage for 1µV/count to 1000V. AC voltage and current
measurements are standard in the Model 197A. TRMS ACV
capability ranges from 1µV/ count to 750V. The Model 197A
measures resistance from 1mΩ. to 220MΩ on seven resistance
ranges. The Model 197A has six current ranges that measure
current from 1nA (10⁻⁹A) to 10A.
The dB function makes it possible to compress a large range
of readings into a much smaller scope. Model 197A dBm
measurements can be referenced to 50, 75,93,135, 300 or 600Ω
(default), but can be modified with the use of the relative
(REL) feature.
The Model 197A has two IEEE-488 Interface options: The Model
1972A and the Model 1973A. These optional interfaces enhance
the capabilities of the Model 197A by allowing programmed
control over the IEEE-488 bus. The Model 1972A also includes
an analog output. The bus commands are the same for each
Interface and respond to IEEE-488 protocol.
The Model 197A includes the following features:
1. Six Measurement Functions — DCV, ACV, DC A, ACA, OHMS and
dB all built in.
2. (REL) Relative Mode — The relative mode allows offsets to
be nulled out (e.g. test lead resistance for low resistance
measurements) and selects a variety of reference impedances
for dB measurements.
3. Digital Calibration — A non-volatile RAM stores
calibration constants and can be performed from the front
panel or over the IEEE-488 bus.
4. Data Logger — A data storage buffer is included to allow
up to 100 readings and minimum/maximum readings be
internally stored at a user selectable rate. The buffer may
be read and controlled from the front panel or over the
IEEE-488 bus. In the talk-only mode, the output rate can
also be programmed.
5. Autoranging — The Model 197A includes a fast autoranging
feature for easier measurements.
6. 5-1/2 Digit Resolution — The Model 197A has a ±220,000
count A/D that surpasses the more common ±199,999 count A/D.
7. Four Terminal Ohms — These terminals are used to
eliminate the voltage from across the current carrying leads.
8. Sensitivity — The Model 197A has 1µV, lmΩ and 1nA
sensitivity. The 1µV of sensitivity allows minute levels of
offset, temperature etc. A 1nA sensitivity allows low
current measurements without special equipment. Measure
leakage, bias and offset current. A 1mΩ sensitivity allows
easy low resistance measurements.
9. Electroluminescent Display Backlight — A switch
selectable electroluminescent display backlight used to
enhance the liquid crystal display under low light or dark
conditions.
10. dB Reference Impedances — Selectable dB reference
impedances of 50Ω, 75Ω, 93Ω,135Ω, 300Ω and 600Ω (default).
Manual Type:
Service and User Manual
Pages:
82
Size:
6.96 Mbytes (7302572 Bytes)
Language:
english
Revision:
B
Manual-ID:
197A-901-01
Date:
Quality:
Scanned document, all readable.
Upload date:
2014 03 02
MD5:
a15f0d124af723cb0f6eddca2044118d
Downloads:
1968
Manual Type:
User Manual
Pages:
62
Size:
2.66 Mbytes (2791842 Bytes)
Language:
english
Revision:
C
Manual-ID:
197A-901-01
Date:
2001 02 01
Quality:
Scanned document, all readable.
Upload date:
2018 08 21
MD5:
ae612ca099ea5e57bf91814638ff206d
Downloads:
436
Information
This manual contains information necessary for operating and
servicing the Model 197A Autoranging Microvolt DMM and the
1978 Rechargeable Battery Pack. This section of the manual
contains general information and an initial operation
procedure. The rest of the manual is organized as follows:
• Section 2 contains detailed bench operation information
for the Model 197A.
• Section 3 contains the information needed to verify the
accuracy of the Model 197A. Performance verification can be
done upon receipt of the unit or whenever the basic accuracy
of the instrument is in question.
• Section 4 contains information on maintenance and
calibration for the Model 197A.
NOTE
The Models 1973A and 1972A IEEE-488 interfaces come supplied
with their own manual.
Add Comment
Insert Link
Please enter the link of the website
Optionally you can add display text
Insert Email
Please enter the email address
Optionally add any display text
Insert Image
Please enter the link of the image
Insert YouTube Video
Please enter the link of the video
Privacy Policy
This policy contains information about your privacy. By posting, you are declaring that you understand this policy:
- Your name, rating, website address, town, country, state and comment will be publicly displayed if entered.
- Aside from the data entered into these form fields, other stored data about your comment will include:
- Your IP address (not displayed)
- The time/date of your submission (displayed)
- Your email address will not be shared. It is collected for only two reasons:
- Administrative purposes, should a need to contact you arise.
- To inform you of new comments, should you subscribe to receive notifications.
- A cookie may be set on your computer. This is used to remember your inputs. It will expire by itself.
This policy is subject to change at any time and without notice.
Terms and Conditions
These terms and conditions contain rules about posting comments. By submitting a comment, you are declaring that you agree with these rules:
- Although the administrator will attempt to moderate comments, it is impossible for every comment to have been moderated at any given time.
- You acknowledge that all comments express the views and opinions of the original author and not those of the administrator.
- You agree not to post any material which is knowingly false, obscene, hateful, threatening, harassing or invasive of a person's privacy.
- The administrator has the right to edit, move or remove any comment for any reason and without notice.
Failure to comply with these rules may result in being banned from further commenting.
These terms and conditions are subject to change at any time and without notice.
Comments