Informacje o sprzęcie

General Radio Company 716-C Inny
Producent:
General Radio Company
Modelu: 716-C
Data: 1959
Kategorii: Przyrządy pomiarowe
Grupa: Inny
Opis: Capacitance Bridge
Informacje:

The Type 716-C Capacitance Bridge is a Schering bridge which is direct reading in capacitance over the frequency range from 30 c to 300 kc and in dissipation factor at four specific frequencies, 100 c, 1 kc, 10 kc, 100 kc. The resistance balance is made by means of a variable capacitor connected across one of the ratio arms, as shown in Figure 1. Hence its reading in dissipation factor is proportional to the ratio of the applied frequency to the frequency for which the RANGE SELECTOR switch is set. The bridge may also be used for all types of substitution measurements by the addition of a fixed or variable balancing capacitor. The direct-reading scales greatly simplify the necessary calculations for capacitance and dissipation factor.

Te Podręczniki są dostępne dla powyższego urządzenia:

Typ instrukcji: Serwis i User Manual GR-8240-Manual-Page-1-Picture
Stron: 28
Rozmiar: 17.50 Mbytes (18347201 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer: 681-K
Data: 01 listopad 1959
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: b339dc3fc3d79818ce9ee3e830f88a06
Pliki do pobrania: 79 od 30 grudzień 2016
Informacje:

Section 1.0 INTRODUCTION ... 1 1.1 General ... 1 1.2 Range and Accuracy ... 1 Section 2.0 INSTALLATION ... 2 2.1 Accessories Supplied ... 2 2.2 Accessories Required ... 2 2.3 Connections ... 2 Section 3.0 MEASUREMENTS ... 2 3.1 Direct Reading Method ... 2 3.2 Substitution Method ... 6 Section 4.0 SPECIAL MEASUREMENTS ... 7 4.1 Measurement of High Resistance ... 7 4.2 Measurement of Large Inductance ... 8 4.3 Partial Substitution Methods ... 8 4.4 Series Substitution Methods ... 9 4.5 Series Resistance Method ... 10 4.6 Parallel Resistance Method ... 10 Section 5.0 Other USES ... 11 5.1 Voltage Limits ... 11 5.2 Frequency Range ... 11 5.3 Measurement of Dielectrics ... 12 5.4 Measurement of Direct Capacitance ... 13 5.5 Guard Electrodes ... 14 5.6 Polarizing Voltage . ... 15 Section 6.0 CONSTRUCTION ... 15 6.1 Electrical Circuit ... 15 6.2 Adjustments ... 15

GR-8240-Manual-Page-1-Picture


Typ instrukcji: Serwis i User Manual GR-8256-Manual-Page-1-Picture
Stron: 22
Rozmiar: 9.95 Mbytes (10434607 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer: 681-K
Data: 01 listopad 1959
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: 11780845be95e98e2d3fd7641424bc0d
Pliki do pobrania: 78 od 30 grudzień 2016
Informacje:

Section 1.0 INTRODUCTION ... 1 1.1 General ... 1 1.2 Range and Accuracy ... 1 Section 2.0 INSTALLATION ... 2 2.1 Accessories Supplied ... 2 2.2 Accessories Required ... 2 2.3 Connections ... 2 Section 3.0 MEASUREMENTS ... 2 3.1 Direct Reading Method ... 2 3.2 Substitution Method ... 6 Section 4.0 SPECIAL MEASUREMENTS ... 7 4.1 Measurement of High Resistance ... 7 4.2 Measurement of Large Inductance ... 8 4.3 Partial Substitution Methods ... 8 4.4 Series Substitution Methods ... 9 4.5 Series Resistance Method ... 10 4.6 Parallel Resistance Method ... 10 Section 5.0 Other USES ... 11 5.1 Voltage Limits ... 11 5.2 Frequency Range ... 11 5.3 Measurement of Dielectrics ... 12 5.4 Measurement of Direct Capacitance ... 13 5.5 Guard Electrodes ... 14 5.6 Polarizing Voltage . ... 15 Section 6.0 CONSTRUCTION ... 15 6.1 Electrical Circuit ... 15 6.2 Adjustments ... 15

GR-8256-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics