Informacje o sprzęcie

Philips PM 3580 Logic Analyzer
Producent:
Philips
Modelu: PM 3580
Data: 1990
Kategorii: Przyrządy pomiarowe
Grupa: Logic Analyzer
Opis: Dual logic analysis
Informacje:

"T" he PM 3580/PM 3585 Logic Analyzer family is a new 1 generation of general purpose logic analyzers giving twice the information with only half the work. All four models of this family {PM 3580/30, PM 3580/60, PM 3585/60, PM 3585/90) feature an exclusive Dual Analysis Per Pin architecture allowing these instruments to analyze and store state and timing data on each of up to 96 channels in a single acquisition at full speed, ail time correlated. No more Dual probing; no more repeat measurements needed. The PM 3580 instruments handle 100 MHz timing and 50 MHz state acquisition on aii channeis simultaneously. The PM 3585 instruments handle 200 MHz timing and 50 MHz state acquisition on all channeis simultaneously. Operation of the instruments is more intuitive and easier than ever to learn. The modern Human Interface is user- friendly both in understanding and operation. Whenever you need them, popup menus will remind you of the choices available. So even if you do not use a logic Analyzer very often, you will not be guessing. And when you know exactly where you want to be, you will find the short cuts even faster. For instance, you can type T to move the display directly to the trigger point. No menu needs to be involved. Simultaneous State and Timing Per Pin PM3585: Two Analyzers Both a timing section and a state section simultaneously observe the same target signals. The pattern recognition results (timing events and state events) of both sections are routed to one common sequencer. The sampled timing and state data are routed to the acquisition memory which can store a total of 2K samples (1K for PM 3580 units) and which you can assign to timing only data (100%), timing + glitch data (50%/50%), timing + state data (50%/50%), or state only data (100%). The pattern recognition logic for state and timing patterns operates independently from the storage mode you select. This allows you always to search for state and timing patterns in parallel. Inside your PM 3585 Logic Analyzer there are two independant Logic Analyzers, both having this unique Dual Analysis Per Pin architecture. These two analyzers can arm each Other when and where necessary in their respective sequences. Channeis can be assigned in groups of 16 to either Analyzer or remain unassigned. Both PM 3580 and PM 3585 units can use any channel as a state/externa! clock. Furthermore, any channel can be used as a clock qualifier. This is another unique feature of this iogic Analyzer family. A maximum of 4 state clocks can be defined at the same time (per Analyzer in PM 3585 units). Timing data is stored using the transitional timing mechanism. This guarantees an optimal usage of acquisition memory. The key features of ail four models are as follows: • “Dual Analysis Per Pin (DAPP)’’ architecture (simultaneous, correiated state and timing acquisition on all channeis) • Transitional timing on ail channels • Powerful triggering functionality integrating state & timing trigger functions in the same trigger sequence • Eight-ievei sequencer with full conditional structure (If...Then...Else) • Eight state trigger words • One range recognizer • Three timing trigger words • One edge detector • One glitch detector • Absolute or relative time stamp, always at full speed (5 ns resolution) • Powerful selective data acquisition functions.

Te Podręczniki są dostępne dla powyższego urządzenia:

Typ instrukcji: Instrukcja obsługi Philips-6725-Manual-Page-1-Picture
Stron: 70
Rozmiar: 3.46 Mbytes (3626184 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer: 4022 104 90151
Data: 1990
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: a4397af5e0128232009126031dca24aa
Pliki do pobrania: 266 od 18 maj 2015
Informacje:

Getting started guide Introduction 5 Exploring the Instrument 9 Front Panel 10 Rear Panel 11 Keyboard 12 Power On 13 Experimenting with Fields 14 Confirmation Fields 15 Pod Field 15 Other Field Types 16 A List Field 16 Connecting Signals to be Measured 17 Summary 19 Timing Acquisition 21 The Purpose of Timing Acquisition 22 A Practical Problem 22 Logic Target PF 8669/20 22 Connecting the Logic Target 23 Setup and Acquisition 23 The Timing Display 24 Specifying Signal Names 25 The Format Menu 26 Measurements 29 Measuring a Time Difference 29 Specifying a Trigger Condition 31 The Trace Menu 32 Menu Areas of the Trace Menu 32 An Example 32 Defining the Events 32 Summary 33 State Acquisition 35 The Purpose of State Acquisition 36 The Problem 36 Connecting the Target 36 Specifying External Clocks 36 Specifying a Trigger Condition 38 Synchronous and Asynchronous Trigger Words 38 Setting Up a Trigger Sequence 39 The State Display 40 Grouping Signals Under a Label 41 Summary 43 Dual Analysis Per Pin (DAPP) Mode 47 Why DAPP? 48 Back to the Practical Problem 48 Connection 48 Setup of the Logic Analyzer 48 Determining the Maximum Clock Speed 50 Summary 51 Use of Microprocessor Disassembly 55 What is a Disassembler? 56 The Problem 57 Connection 57 Setup of the Logic Analyzer 58 Summary 61 Making a Printout 65 Getting Examples from the Disk 67

Philips-6725-Manual-Page-1-Picture


Typ instrukcji: Instrukcja obsługi Philips-7915-Manual-Page-1-Picture
Stron: 128
Rozmiar: 5.77 Mbytes (6045215 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer: 4022 104 90161
Data: 1990
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: 6c36f67c16a9878a185388bb4e58a20f
Pliki do pobrania: 154 od 12 czerwiec 2016
Informacje:

Getting started guide Introduction 5 Exploring the Instrument 9 Front Panel 10 Rear Panel 11 Keyboard 12 Power On 13 Experimenting with Fields 14 Confirmation Fields 15 Pod Field 15 Other Field Types 16 A List Field 16 Connecting Signals to be Measured 17 Summary 19 Timing Acquisition 21 The Purpose of Timing Acquisition 22 A Practical Problem 22 Logic Target PF 8669/20 22 Connecting the Logic Target 23 Setup and Acquisition 23 The Timing Display 24 Specifying Signal Names 25 The Format Menu 26 Measurements 29 Measuring a Time Difference 29 Specifying a Trigger Condition 31 The Trace Menu 32 Menu Areas of the Trace Menu 32 An Example 32 Defining the Events 32 Summary 33 State Acquisition 35 The Purpose of State Acquisition 36 The Problem 36 Connecting the Target 36 Specifying External Clocks 36 Specifying a Trigger Condition 38 Synchronous and Asynchronous Trigger Words 38 Setting Up a Trigger Sequence 39 The State Display 40 Grouping Signals Under a Label 41 Summary 43 Dual Analysis Per Pin (DAPP) Mode 47 Why DAPP? 48 Back to the Practical Problem 48 Connection 48 Setup of the Logic Analyzer 48 Determining the Maximum Clock Speed 50 Summary 51 Use of Microprocessor Disassembly 55 What is a Disassembler? 56 The Problem 57 Connection 57 Setup of the Logic Analyzer 58 Summary 61 Making a Printout 65 Getting Examples from the Disk 67

Philips-7915-Manual-Page-1-Picture


Typ instrukcji: Instrukcja obsługi Philips-7916-Manual-Page-1-Picture
Stron: 256
Rozmiar: 12.78 Mbytes (13402199 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer: 4022 104 90171
Data: 1990
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: aa563f06473959e93a651c1377605d01
Pliki do pobrania: 174 od 12 czerwiec 2016
Informacje:

Getting started guide Introduction 5 Exploring the Instrument 9 Front Panel 10 Rear Panel 11 Keyboard 12 Power On 13 Experimenting with Fields 14 Confirmation Fields 15 Pod Field 15 Other Field Types 16 A List Field 16 Connecting Signals to be Measured 17 Summary 19 Timing Acquisition 21 The Purpose of Timing Acquisition 22 A Practical Problem 22 Logic Target PF 8669/20 22 Connecting the Logic Target 23 Setup and Acquisition 23 The Timing Display 24 Specifying Signal Names 25 The Format Menu 26 Measurements 29 Measuring a Time Difference 29 Specifying a Trigger Condition 31 The Trace Menu 32 Menu Areas of the Trace Menu 32 An Example 32 Defining the Events 32 Summary 33 State Acquisition 35 The Purpose of State Acquisition 36 The Problem 36 Connecting the Target 36 Specifying External Clocks 36 Specifying a Trigger Condition 38 Synchronous and Asynchronous Trigger Words 38 Setting Up a Trigger Sequence 39 The State Display 40 Grouping Signals Under a Label 41 Summary 43 Dual Analysis Per Pin (DAPP) Mode 47 Why DAPP? 48 Back to the Practical Problem 48 Connection 48 Setup of the Logic Analyzer 48 Determining the Maximum Clock Speed 50 Summary 51 Use of Microprocessor Disassembly 55 What is a Disassembler? 56 The Problem 57 Connection 57 Setup of the Logic Analyzer 58 Summary 61 Making a Printout 65 Getting Examples from the Disk 67

Philips-7916-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics