Apparatuur informatie

Conar Coletronics Service Inc. 224 Afsluiterkarakteristiek meter
Fabrikant:
Model:
224
Datum:
1972
Categorie:
Groep:
Omschrijving:
Tube Tester

Informatie

The heart of the Model 224 is the 12-lever switch. With This switch, any tube pin can be connected to any of three circuits. The individual switches, numbered 1 through 12, correspond to the twelve possible tube pins. That is, switch 1 connects to pin 1 of all sockets, switch 2 connects to pin 2 of all sockets, and so on. Switch 10 connects to pin 10 of all sockets as well as to the top cap connector. Note that all sockets do not require all twelve switches, in fact, the compactron socket is the only one having 12 pins, thus requiring all 12 switches. The other sockets will use the first 6, 7, it, 9 or 10 switches, The five pins of the nuvistor sockets, however, do not connect to switches 1 through 5, The tube manufacturers have chosen to call these five pins 2,4, 8, 10 and 12, so this socket uses switches 2, 4,8, 10 and 12. When any of the twelve switches is in the TEST (middle) position, an ac voltage is applied to the corresponding tube pin through the neon lamp. If there is a conductive path of 1 megohm or less between the selected tube electrode and any other electrode, the neon lamp will glow. In this way inter-element shorts and undesirable leakage between electrodes may be discovered. This same circuit can be used to check heater continuity, in which case the lamp should glow if the tube heater is good. When the switch corresponding to the tube heater is placed in the C position (upper), heater voltage is applied to the tube by the B selector switch. Any of 17 separate heater voltages may be chosen by the B switch (position 18 is not used). With the proper switch set to C, the tube healer will light. All other tube elements except the cathode and the other heater connections are placed in the TEST position by setting the appropriate switches. This connects the tube as a diode. When the Press-To-Read-Meter switch is pushed, the neon lamp is disconnected and a voltage and load resistor combination selected by the A switch is connected instead. At the same time, the meter is disconnected from the Adjust Line circuit and reconnected to read the tube current. The current can be read either on the 0 to 100 scale or the REPLACE — ? — GOOD scale.

toon meer

Gebruikershandleiding
Handleidingen type:
Gebruikershandleiding
Pagina’s:
16
Grootte:
282.04 Kbytes (288804 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
06 augustus 2017
MD5:
06111eaec3ad0212b240040eec86d81b
Downloads:
410

Informatie

Supplementary Tube Chart

toon meer

Gebruikershandleiding
Handleidingen type:
Gebruikershandleiding
Pagina’s:
25
Grootte:
719.77 Kbytes (737043 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
05 augustus 2017
MD5:
17e3e01b877cfb633b228c646f734843
Downloads:
592

Informatie

Tube Test Data

toon meer

Gebruikershandleiding
Handleidingen type:
Gebruikershandleiding
Pagina’s:
40
Grootte:
651.95 Kbytes (667600 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
01 januari 1978
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
06 augustus 2017
MD5:
6f8ed0a7f0b4397e98d00fed9e470101
Downloads:
391

Informatie

Assembling and Using Specifications ... Pages 1*2 Operating Instructions ... Pages 3 - S Maintenance ... ... Page* 6 - 8 Assembly Instructions ... Pages 9*35

toon meer

Gebruikershandleiding
Handleidingen type:
Gebruikershandleiding
Pagina’s:
3
Grootte:
1,018.48 Kbytes (1042924 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
01 januari 1973
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
05 augustus 2017
MD5:
81c82b20f2158b0607df6d286cbb87ed
Downloads:
593

Informatie

Tube Test Data

toon meer

Gebruikershandleiding
Handleidingen type:
Gebruikershandleiding
Pagina’s:
30
Grootte:
9.72 Mbytes (10196985 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
01 januari 1972
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
05 augustus 2017
MD5:
9d78aeb02e4b4d146a42ece0131bfa4e
Downloads:
255

Informatie

Tube Test Data

toon meer

Add Comment

* Required information
1000
Captcha Image

Comments