Equipment information

Fluke 8062A Digital multimeter
Manufacturer:
Model:
8062A
Date:
1982
Category:
Group:
Description:
True-rms Multimeter

Information

Your Fluke Model 8062A is a handheld, microcomputer-based 4-1/2 digit multimeter that is ideally suited for use in the field, laboratory, shop or home. The 8062A has all the features that have become accepted standards for quality handheld multimeters, as well as some new features that have not been offered before in a handheld multimeter. New features include the following: · True rms measurements for ac signals up to 30 kHz. · Resistance measurements up to 300 MW. · Ability to store any input signal as an offset or relative reference value. Other features include: · FUNCTIONS: Standard DMM measurement functions, such as ac and dc volts and ac and dc current, as well as resistance, continuity, and diode test. · RANGES: Leading zero suppression. Automatic polarity. Overrange indication. Protection from overloads and transients up to 1500V peak. Dual-slope integration a/d conversion to ensure noise-free measurements. Autoranging MW resistance range (to 300 MW), as well as four fixed resistance ranges from 200W to 200 kW. · OPERATOR CONVENIENCE: 4-1/2 digit Liquid Crystal Display. Software-control self-test routines for quick verification of internal circuitry and operation. · POWER: 170 hours of continuous operation can be expected from a 9V alkaline battery (NEDA 1604).

show more

Service and User Manual
Manual Type:
Service and User Manual
Pages:
124
Size:
5.90 Mbytes (6183812 Bytes)
Language:
english
Revision:
1
Manual-ID:
PN 609153
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
2014 11 29
MD5:
123949df8aa2ef1ba8f4b27d8afbee09
Downloads:
1212

Information

This manual pertains to instruments with serial number 6830XXX or higher. 1 Introduction and Specifications ... 1-1 1-1. Introduction ... 1-3 1-2. Specifications ... 1-4 2 Operation Instructions ... 2-1 2-1. Introduction ... 2-3 2-2. Unpacking Your Instrument ... 2-3 2-3. Battery Installation or Replacement ... 2-3 2-4. Fuse Replacement ... 2-5 2-5. Physical Features ... 2-6 2-6. Front Panel ... 2-6 2-7. Display ... 2-8 2-8. Signal Input Limits ... 2-9 2-9. Operation ... 2-10 2-10. Power-On Self-Test ... 2-10 2-11. AC/DC Voltage (V) ... 2-11 2-12. True RMS Measurement ... 2-11 2-13. AC-Coupled AC Measurements ... 2-12 2-14. Waveform Comparison and Conversion ... 2-13 2-15. High Impedance DC Voltage ... 2-14 2-16. AC/DC Current (A) ... 2-15 2-17. Resistance (W) ... 2-18 2-18. Autoranging Megohms ... 2-19 2-19. Autoranging Kilohms ... 2-20 2-20. Diode Test (G) ... 2-21 2-21. Relative (REL) ... 2-22 2-22. Continuity ( ) ... 2-25 2-23. Initial Check-Out Procedure ... 2-25 3 Theory of Operation ... 3-1 3-1. Introduction ... 3-3 3-2. Functional Description ... 3-3 3-3. Microcomputer ... 3-3 3-4. Measurement Acquisition Chip (MAC) ... 3-5 3-5. A/D Converter Cycle ... 3-5 3-7. Current Measurement ... 3-9 3-8. Resistance Measurement ... 3-10 3-9. Continuity Measurement ... 3-11 4 Maintenance ... 4-1 4-1. Introduction ... 4-3 4-2. Service Information ... 4-3 4-3. General Information ... 4-5 4-5. Disassembly and Reassembly ... 4-5 4-6. Calibration and Backup Fuse Access ... 4-6 4-7. Main PCB Access ... 4-7 4-8. LCD and Microcomputer PCB Disassembly and Assembly ... 4-8 4-9. Backup Fuse Replacement ... 4-11 4-10. Cleaning ... 4-11 4-11. Performance Tests ... 4-12 4-12. Initial Procedure ... 4-12 4-13. Microcomputer and Display Test ... 4-12 4-14. Voltage Test ... 4-13 4-15. Resistance Test ... 4-14 4-16. Continuity Test ... 4-15 4-17. Current Test ... 4-15 4-18. Diode Test ... 4-17 4-19. Calibration Adjustments ... 4-17 4-20. Troubleshooting ... 4-19 4-21. Self-Tests ... 4-19 4-22. Ratio Self-Test ... 4-19 4-23. Switch Decoding Self-Test ... 4-20 4-24. Troubleshooting Guide ... 4-21 5 List of Replaceable Parts ... 5-1 5-1. Introduction ... 5-3 5-2. How to Obtain Parts ... 5-3 5-3. Manual Status Information ... 5-4 5-4. Newer Instruments ... 5-4 5-5. Service Centers ... 5-4 6 Accessory Information ... 6-1 6-1. Introduction ... 6-3 6-2. Deluxe Carrying Case (C90) ... 6-3 6-3. Temperature Probes (80T-150C and 80T-150F) ... 6-3 6-4. Current Transformer (80I-600) ... 6-6 6-5. High Voltage Probe (80K-6) ... 6-6 6-6. High Voltage Probe (80K-40) ... 6-7 6-7. High Frequency Probe (83RF) ... 6-7 6-8. High Frequency Probe (85RF) ... 6-8 6-9. Current Shunt (80J-10) ... 6-9 6-10. AC/DC Current Probe (Y8100) ... 6-9 6-11. AC Current Transformer (Y8101) ... 6-10 6-12. Safety Designed Test Lead Set (TL70) ... 6-11 6-13. Deluxe Test Lead Set (Y8134) ... 6-11 6-14. Slim Flex Test Lead Set (Y8140) ... 6-12 6-15. Cables and Adapters ... 6-12 7 Schematic Diagrams ... 7-1

show more

Service and User Manual
Manual Type:
Service and User Manual
Pages:
96
Size:
5.75 Mbytes (6031244 Bytes)
Language:
english
Revision:
3
Manual-ID:
632695
Date:
Quality:
Scanned document, all readable.
Upload date:
2016 01 27
MD5:
3f399ef121674fe122ee7905cd4d8d06
Downloads:
608

Information

1 INTRODUCTION AND SPECIFICATIONS ... 1-1 l-l. INTRODUCTION ... 1-1 1-2. SPECIFICATIONS ... 1-2 2 OPERATING INSTRUCTIONS ... 2-1 2-1. INTRODUCTION ... 2-1 2-2. UNPACKING YOUR INSTRUMENT ... 2-1 2-3. BATTERY INSTALLATION OR REPLACEMENT .. 2-1 2-4. FUSE REPLACEMENT ... 2-3 2-5. PHYSICAL FEATURES ... 2-3 2-6. Front Panel ... 2-3 2-7. Display ... 2-6 2-8. SIGNAL INPUT LIMITS ... 2-6 2-9. OPERATION ... 2-7 2-10. Power-On Self Test ... 2-7 2-11. AC/DC VOLTAGE (V) ... 2-8 2-16. AC/DC Current (A) ... 2-12 2-17. Resistance (il) ... 2-14 2-20. Diode Test ... 2-16 2-21. Relative (REL) ... 2-17 2-22. Continuity ( -n-»»I ) ... 2-19 2-23. INITIAL CHECK-OUT PROCEDURE ... 2-20 3 THEORY OF OPERATION ... 3-1 3-1. INTRODUCTION ... 3-1 3-2. FUNCTIONAL DESCRIPTION ... 3-1 3-3. Microcomputer ... 3-1 3-4. Measurement Acquisition Chip (MAC) ... 3-3 3-5. A/D Conversion Cycle ... 3-3 3-6. Voltage Measurement ... 3-5 3-7. Current Measurement ... 3-6 3-8. Resistance Measurement ... 3-7 3-10. Continuity Measurement ... 3-7 i (continued on page ii) 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-2. SERVICE INFORMATION ... 4-2 4-3 GENERAL INFORMATION ... 4-2 4-4. Handling Precautions for Using Static Sensitive Devices ... 4-2 4-5. Disassembly and Reassembly ... 4-3 4-9. Backup Fuse Replacement ... 4-8 4-10. Cleaning ... 4-8 4-11. PERFORMANCE TESTS ... 4-9 4-12. Initial Procedure ... 4-9 4-13. Microcomputer and Display Test ... 4-9 4-14. Voltage Test ... 4-9 4-15. Resistance Test ... 4-9 4-16. Continuity Test ... 4-10 4-17. Current Test ... 4-12 4-18. Diode Test ... 4-12 4-19. CALIBRATION ADJUSTMENTS ... 4-12 4-20. TROUBLESHOOTING ... 4-14 4-21. Self-Tests ... 4-15 4-24. Troubleshooting Guide ... 4-16 5 LIST OF REPLACEABLE PARTS ... 5-1 5-1. INTRODUCTION ... 5-1 5-2. HOW TO OBTAIN PARTS ... 5-2 5-3. MANUAL STATUS INFORMATION ... 5-2 5-4. NEWER INSTRUMENTS ... 5-2 5-5. SERVICE CENTERS ... 5-2 6 ACCESSORY INFORMATION ... 6-1 6-1. INTRODUCTION ... 6-1 6-2. DELUXE CARRYING CASE (C90) ... 6-1 6-3. TEMPERATURE PROBES (80T-150C and 80T-I50) ... 6-1 6-4. CURRENT TRANSFORMER (801-600) ... 6-4 6-5. HIGH VOLTAGE Probe (80K-6) ... 6-4 6-4. HIGH VOLTAGE Probe (80K-40) ... 6-4 6-7 HIGH FREQUENCY Probe (83RF) ... 6-5 6-8 HIGH FREQUENCY Probe (85RF) ... 6-5 6-9. BATTERY ELIMINATOR (A81) ... 6-6 6-10. CURRENT SHUNT (80J-10) ... 6-6 6-11. AC/DC CURRENT Probe (Y8100) ... 6-7 6-12. AC CURRENT TRANSFORMER (Y8101) ... 6-8 6-13. SAFETY DESIGNED TEST LEAD SET (Y8132) ... 6-8 6-14. DELUXE TEST LEAD SET (Y8134) ... 6-8 6-15. SLIM FLEX TEST LEAD SET (Y8140) ... 6-8 6-16. CABLES AND ADAPTERS ... 6-9 7 SCHEMATIC DIAGRAMS ... 7-1

show more

Service and User Manual
Manual Type:
Service and User Manual
Pages:
100
Size:
3.60 Mbytes (3776961 Bytes)
Language:
english
Revision:
Manual-ID:
P/N 632695
Date:
1982 03 01
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
2017 08 10
MD5:
7041d10e91f921d365d9a94d76964009
Downloads:
697

Information

Instruction Manual INTRODUCTION AND SPECIFICATIONS ... 1-1 1-1. INTRODUCTION ... M 1-2. SPECIFICATIONS., ... 1-2 2 OPERATING INSTRUCTIONS ... 2-1 2-1. INTRODUCTION ... 2-1 2-2. UNPACKING YOUR INSTRUMENT ... 2-1 2-3. BATTERY INSTALLATION OR REPLACEMENT .. 2-1 2-4. FUSE REPLACEMENT ... 2-3 2-5. PHYSICAL FEATURES ... 2-3 2-6. Front Panel ... 2-3 2-7. Display ... 2-6 2-8. SIGNAL INPUT LIMITS ... 2-6 2-9. OPERATION ... 2-7 2-10. Power-On Self Test ... 2-7 2-11. AC/DC VOLTAGE (V) ... 2-8 2-16. AC/DC Current (A) ... 2-12 2-17. Resistance (O) ... 2-14 2-20. Diode Test ... 2-16 2-21. Relative (REL) ... 2-17 2-22. Continuity (-*♦■>!! ) ... 2-19 2-23. INITIAL CHECK-OUT PROCEDURE ... 2-20 3 THEORY OF OPERATION ... 3-1 3-1. INTRODUCTION ... 3-1 3-2. FUNCTIONAL DESCRIPTION ... 3-1 3-3. Microcomputer ... 3-1 3-4. Measurement Acquisition Chip (MAC) ... 3-3 3-5. A/D Conversion Cycle ... 3-3 3-6. Voltage Measurement ... 3-5 3-7. Current Measurement ... 3-6 3-8. Resistance Measurement ... 3-7 3-10. Continuity Measurement ... 3-7 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-2. SERVICE INFORMATION ... 4-1 4-3. GENERAL INFORMATION ... 4-2 4-4. Handling Precautions for Using Static Sensitive Devices 4-2 4-5. Disassembly and Reassembly ... 4-3 4-9. Backup Fuse Replacement ... 4-8 4-10. Cleaning ... 4-8 4-11. PERFORMANCE TESTS ... 4-9 4-12. Initial Procedure ... 4-9 4-13. Microcomputer and Display Test ... 4-9 4-14. Voltage Test ... 4-9 4-15. Resistance Test ... 4-9 4-16. Continuity Test ... 4-10 4-17, Current Test ... 4-12 4-18. Diode Test ... 4-12 4-19. CALIBRATION ADJUSTMENTS ... 4-12 4-20. TROUBLESHOOTING ... 4-14 4-21. Self-Tests ... 4-14 4-24. Troubleshooting Guide ... 4-15 5 LIST OF REPLACEABLE PARTS ... 5-1 5-1. INTRODUCTION ... 5-1 5-2. HOW TO OBTAIN PARTS ... 5-1 5-3. MANUAL CHANGE AND BACKDATING INFORMATION ... 5-2 6 ACCESSORY INFORMATION ... 6-1 6-1. INTRODUCTION ... 6-1 6-2. DELUXE CARRYING CASE (C90) ... 6-I 6-3. TEMPERATURE PROBES (80T-150C and 80T-150F) . 6-1 6-4. CURRENT TRANSFORMER (801-600) ... 6-4 6-5. HIGH VOLTAGE Probe (80K-6) ... 6-4 6-6. HIGH VOLTAGE Probe (80K-40) ... 6-4 6-7. HIGH FREQUENCY Probe (83RF) ... 6-5 6-8. HIGH FREQUENCY Probe (85RF) ... 6-5 6-9. BATTERY ELIMINATOR (A81) ... 6-6 6-10. CURRENT SHUNT (80J-10) ... 6-6 6-11. AC/DC CURRENT Probe (Y8100) ... 6-7 6-12. AC CURRENT TRANSFORMER (Y8101) ... 6-8 6-13. SAFETY DESIGNED TEST LEAD SET (Y8132) ... 6-8 6-14. DELUXE TEST LEAD SET (Y8134) ... 6-8 6-15. SLIM FLEX TEST LEAD SET (Y8140) ... 6-8 6-16. CABLES AND ADAPTERS ... 6-9 7 SCHEMATIC DIAGRAMS ... 7-1