Apparecchiature informatiche

Mindray PM-8000 Sistema di monitoraggio
Produttore:
Mindray
Modello: PM-8000
Data: 2005
Categoria: Attrezzature mediche e biomediche
Gruppo: Sistema di monitoraggio
Descrizione: Portable Multi-parameter Patient Monitor
Informazioni:

PM-8000 is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult, pediatric and neonate. In addition, the user may select the different parameter configuration according to different requirements. PM-8000 can be connected to the central Monitoring System via the Mindray network so as to form a network Monitoring System. PM-8000 (Figure 1-1) can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP, IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters. The power switch (POWER) of the monitor is on the upper left part of the front panel (2 in the figure below). The POWER LED (3 in the figure below) is used to indicate the AC Mains condition. This LED is illuminated when AC Mains is connected. BATT LED (4 in the figure below) is on the left side of POWER LED, used to indicate the battery condition. This LED is off when no battery is loaded. After the battery is loaded, this BATT. LED will be illuminated if AC Mains is connected, or lighted off when AC Mains is disconnected and at the same time the monitor is not powered on, or flashes when though AC Mains is disconnected but the monitor is powered on. The alarm indicator (ALARM) is on the upper part of the front panel (1 in the figure below), which will flash as soon as any alarm event happens. Sensor and probe sockets are on the left side of the monitor while the recorder is on the right side. Other sockets and power connector is on the rear panel of the monitor. PM-8000 is a user-friendly device with operations conducted by a few buttons on the front panel and a rotary knob.

Questi manuali sono disponibili per l'attrezzatura di cui sopra:

Tipo manuale: Manuale di servizio Mindray-10238-Manual-Page-1-Picture
Pagine: 83
Dimensioni: 801.76 Kbytes (821003 Bytes)
Lingua: Inglese
Revisione: 2.0
Manuale-ID/numero: 8000-20-10282
Data: 24 luglio 2005
Qualità: Documento elettronico, senza ricerca, molto ben leggibile.
Data di aggiunta:
MD5: 08543294404b87043980dc3b4a80104b
Downloads: 294 dal 05 febbraio 2018
Informazioni:

Chapter 1 Introduction ... 1-1 I. General ... 1-1 II. Appearance ... 1-2 2.1 Screen display ... 1-2 2.2 Button Functions ... 1-6 2.3 Interfaces ... 1-8 2.4 Built-in rechargeable battery ... 1-10 III. Hardware principle ... 1-11 3.1 Power board ... 1-12 3.2 PM-8000 main control board ... 1-13 3.3 Structure diagram ... 1-14 3.4 Description ... 1-14 3.5 Button schematic diagram and principle ... 1-16 3.6 Maintenance part of TR60-A recorder ... 1-17 Chapter 2 Monitor Functions and Principles ... 2-1 I. Introduction ... 2-1 II. ECG/RESP parameters ... 2-2 2.1 ECG ... 2-2 2.2 RESP ... 2-2 2.3 NIBP ... 2-3 2.4 SpO2 ... 2-3 2.5 TEMP ... 2-4 2.6 IBP ... 2-4 Chapter 3 Checks and Tests ... 3-1 I. System checks ... 3-1 II. Testing and calibrating each parameter ... 3-9 Chapter 4 Troubleshooting ... 4-1 I. Disassembly graph of each part of PM-8000 ... 4-1 II. Troubleshooting guidance ... 4-2 Chapter 5 Installation ... 5-1 I. Unpack inspection ... 5-1 II. Preparations before power-on ... 5-1 III. Turn on the power ... 5-1 IV. Other precautions ... 5-1 Chapter 6 Basic Operations ... 6-1 I. Basic operation guidance ... 6-1 II. Use PM-8000 ... 6-1 Chapter 7 Cleaning and Disinfection ... 7-1 I. Maintenance checks ... 7-1 II. General cleaning ... 7-1 III. Sterilization ... 7-2 IV. Precautions and cleaning ... 7-3 V. IBP transducer cleaning and disinfection(reusable) ... 7-4 VI. TEMP sensor cleaning and disinfection (reusable) ... 7-6 Chapter 8 Maintenance ... 8-1 Chapter 9 Network Link ... 9-1 I. Network performance ... 9-1 II. Application ... 9-1 Appendix I: System Alarm Prompt ... AI-i Appendix II: Product Specifications ... AII-i 1. Classification ... AII-i 2. Specifications ... AII-i

Mindray-10238-Manual-Page-1-Picture


Tipo manuale: Manuale d'uso Mindray-10237-Manual-Page-1-Picture
Pagine: 200
Dimensioni: 2.25 Mbytes (2355909 Bytes)
Lingua: Inglese
Revisione: 2.5
Manuale-ID/numero: 8000-20-10197
Data: 01 agosto 2005
Qualità: Documento elettronico, senza ricerca, molto ben leggibile.
Data di aggiunta:
MD5: 18ab8a475e406e9c686e849bb8eeea48
Downloads: 1017 dal 05 febbraio 2018
Informazioni:

Chapter 1 Introduction ... 1-1 1.1 General Information ... 1-3 1.2 Screen Display ... 1-5 1.3 Button Functions ... 1-8 1.4 Interfaces ... 1-10 1.5 Batteries ... 1-13 Chapter 2 Getting Started ... 2-1 2.1 Open the Package and Check ... 2-1 2.2 Connect the Power Cables ... 2-1 2.3 Power on the Monitor ... 2-2 2.4 Connect Patient Sensors ... 2-2 2.5 Check the Recorder ... 2-3 Chapter 3 System Menu ... 3-1 3.1 Patient Information Setup ... 3-2 3.2 Default Setup ... 3-3 3.3 System Setup ... 3-5 3.4 Selection Setup ... 3-11 3.5 Monitor Version ... 3-12 3.6 Drug Calculation ... 3-13 3.7 Maintenance ... 3-13 3.8 DEMO Function ... 3-18 Chapter 4 Face Select ... 4-1 4.1 Select Operating Screen ... 4-1 4.2 Standard Screen ... 4-1 4.3 Trend Screen ... 4-2 4.4 oxyCRG Screen ... 4-3 4.5 Viewbed Screen ... 4-4 Chapter 5 Alarm ... 5-1 5.1 Alarm Modes ... 5-1 5.2 Alarm verification during power on ... 5-4 5.3 Alarm Cause ... 5-4 5.4 SILENCE and PAUSE ... 5-5 5.5 Parameter Alarm ... 5-6 5.6 When an Alarm Occurs ... 5-7 Chapter 6 Freeze ... 6-1 6.1 General ... 6-1 6.2 Enter/Exit Freeze Status ... 6-1 6.3 Frozen Menu ... 6-2 6.4 Reviewing Frozen Waveform ... 6-2 6.5 Recording Frozen Waveform ... 6-3 Chapter 7 Recording ... 7-1 7.1 General Information on Recording ... 7-1 7.2 Recording Type ... 7-1 7.3 Recording Startup ... 7-4 7.4 Recorder Operations and Status Messages ... 7-5 Chapter 8 Trend and Event ... 8-1 8.1 Trend Graph ... 8-1 8.2 Trend Table ... 8-3 8.3 NIBP Recall ... 8-4 8.4 Alarm Event Recall ... 8-5 Chapter 9 Drug Calculation and Titration Table ... 9-1 9.1 Drug Calculation ... 9-1 9.2 Titration Table ... 9-3 Chapter 10 Patient Safety ... 10-1 Chapter 11 Care / Cleaning ... 11-1 11.1 System Check ... 11-1 11.2 General Cleaning ... 11-2 11.3 Cleaning Agents ... 11-2 11.4 Sterilization ... 11-3 11.5 Disinfection ... 11-3 Chapter 12 ECG/RESP Monitoring ... 12-1 12.1 What Is ECG Monitoring ... 12-1 12.2 Precautions during ECG Monitoring ... 12-1 12.3 Monitoring Procedure ... 12-2 12.4 ECG Screen Hot Keys ... 12-6 12.5 ECG Menu ... 12-7 12.6 ECG Alarm Information and Prompt ... 12-11 12.7 ST Segment Monitoring (optional) ... 12-12 12.8 Arr. Monitoring (optional) ... 12-16 12.9 Measuring RESP ... 12-20 12.10 Maintenance and Cleaning ... 12-24 Chapter 13 SpO2 Monitoring ... 13-1 13.1 PART 1 (MASIMO SpO2 board configuration) ... 13-1 13.1.1 Precautions ... 13-3 13.1.2 Monitoring Procedure ... 13-5 13.1.3 Sensors and Accessories: ... 13-8 13.1.4 Alarm Description and Prompt ... 13-10 13.1.5 Masimo Information ... 13-13 13.2 PART 2 (MINDRAY SpO2 board configuration) ... 13-14 13.2.1 What is SpO2 Monitoring ... 13-14 13.2.2 Precautions during SpO2/Pulse Monitoring ... 13-15 13.2.3 Monitoring Procedure ... 13-16 13.2.4 Limitations for Measurement ... 13-18 13.2.5 SpO2 Menu ... 13-18 13.2.6 Alarm Description and Prompt ... 13-21 13.2.7 Maintenance and Cleaning ... 13-22 Chapter 14 NIBP Monitoring ... 14-1 14.1 Introduction ... 14-1 14.2 NIBP Monitoring ... 14-1 14.3 NIBP SETUP menu ... 14-6 14.4 NIBP Alarm Message ... 14-9 14.5 Maintenance and Cleaning ... 14-11 Chapter 15 TEMP Monitoring ... 15-1 15.1 TEMP Monitoring ... 15-1 15.2 TEMP SETUP Menu ... 15-2 15.3 TEMP Alarm message ... 15-2 15.4 Care and Cleaning ... 15-3 Chapter 16 IBP Monitoring ... 16-1 16.1 Introduction ... 16-1 16.2 Precautions during IBP Monitoring ... 16-1 16.3 Monitoring Procedure ... 16-2 16.4 IBP Menu ... 16-3 16.5 Alarm Information and Prompts ... 16-9 16.6 Maintenance and Cleaning ... 16-11 16.7 ICP Transducer ICT/B (Optional Accessory) ... 16-12 Chapter 17 Accessories ... 17-1 17.1 ECG Accessories ... 17-1 17.2 SpO2 Accessories ... 17-2 17.3 NIBP Accessories ... 17-3 17.4 TEMP Accessories ... 17-3 17.5 IBP Accessories ... 17-4 Appendix A EC Declaration of Conformance ... A-1 Appendix B Product Specification ... B-1 Appendix C EMC ... C-1 Appendix D System Alarm Prompt ... D-1

Mindray-10237-Manual-Page-1-Picture