Apparecchiature informatiche

Fluke 2100A Termometro
Produttore:
Fluke
Modello: 2100A
Data: 1975
Categoria: Strumenti di misura
Gruppo: Termometro
Descrizione: DIGITAL THERMOMETER
Informazioni:

The Fluke Model 2100A is a digital, thermocouple thermometer, employing the dual-slope integration technique, and capable of making precise temperature measurements in either degrees Fahrenheit (°F) or degrees Celsius (°C). The instrument is fully guarded and features a fully isolated input. 1-3. The 2100A has a five-digit readout (plus sign) capable of indicating up to ±3999.9 degrees. However, the range of the instrument is determined by the type of thermocouple used. The instrument can be ordered, configured to use any of the following types: J, K, T, E, R and S. Table 1-1 shows the temperature ranges for each of these types. Resolution of the instrument is 0.1 degree, except in instruments using a type R or a type S thermocouple and indicating in °F, when resolution is 0.2 degrees. The readout features 0.5 inch characters, fixed decimal point, and leading-zero suppression for the two most significant digits. 1-4. The 2100A is available in three basic models: the 2100A—03, the 2100A-06, and the 2100A-10. The 2100A--03 is a single-point instrument (one input); the 2100A-10 is a multi-point instrument (10 inputs). Both of these models are tailored at the factory to use only one specific type of thermocouple. Once tailored, the 2100A— 03 and 2100A—10 are limited to that one type, but can be converted to any one of the Other five at any time, by means of a conversion kit. 1-5. The 2100A—06 is a multi-type instrument. It is tailored to accept inputs from any of the six different types of thermocouple, but only one type at any given time. (The 2100A—06 is not a multi-point instrument). In effect, the 2100A—06 is a 2100A—03 that can be rapidly converted to accept different thermocouples, by means of integral selector switches, rather than conversion kits. For valid indications from a 2100A—06, the selector switch depressed must correspond to the type of thermocouple being used. In addition, the 2100A—06 can accept linearized voltage inputs on either of two selectable mV ranges directly from Other transducers, such as bridge-connected strain gauges. Table 1-2 is a summary of the differences between the three basic models of the 2100A.

Questi manuali sono disponibili per l'attrezzatura di cui sopra:

Tipo manuale: Servizio e manuale utente Fluke-7696-Manual-Page-1-Picture
Pagine: 146
Dimensioni: 7.75 Mbytes (8127524 Bytes)
Lingua: Inglese
Revisione: 1
Manuale-ID/numero: 397075
Data: novembre 1975
Qualità: Documento scansionato, tutto leggibile.
Data di aggiunta:
MD5: 50edd2d5d48aed533abf6d195b69e64e
Downloads: 156 dal 08 febbraio 2016
Informazioni:

1 INTRODUCTION AND SPECIFICATIONS ... 1-1 1-1. INTRODUCTION ... 14 1-14. SPECIFICATIONS ... 1-3 2 OPERATING INSTRUCTIONS . ... 2-1 24. INTRODUCTION ... 2-1 2-3. SHIPPING INFORMATION ... 2-1 2-6. INPUT POWER ... 2-1 2-9. RACK/PANEL INSTALLATION ... 2-1 2-11. OPERATING FEATURES ... 2-1 2-13. OPERATING NOTES ... 2-5 245. AC Line Connection ... 2-5 247. Fuse Replacement ... 2-5 2-19. Open inputs ... 2-5 2-21. OPERATION ... 2-5 2-22. Models 2100A—03 and 2100A—10 . . ... 2-5 2-24. Model 2100A-06 ... 2-6 2-26. Model 2100A/Model 2150A Set ... 2-6 3 THEORY OF OPERATION ... 3-1 3-1. INTRODUCTION ... 3-1 3-3. OVERALL FUNCTIONAL DESCRIPTION ... . 3-1 3-5. Thermocouple ... 3-2 3-8. Cold Junction Compensation ... 3-2 3-10. Buffer Amplifier ... 3-2 3-12. A/D Converter ... 3-2 3-16. Linearizer ... 3-3 3-19. Display ... 3-3 3-21. CIRCUIT ANALYSIS ... 3-3 3-22. Reference Junction Compensation ... 3-3 3-25. Buffer Amplifier ... 34 3-29. A/D Converter ... 3-5 3-33. Linearizer ... 3-6 348. Summary of Linearizer Operation ... 3-7 4 MAINTENANCE. ... 4-1 4-1. INTRODUCTION ... 4-1 44. GENERAL MAINTENANCE ... 4-1 4-7. Cleaning ... 4-2 4-9. Fuse Replacement ... ' ... 4-2 4-11. Service Tools ... 4-2 4-13. OPERATIONAL EVALUATION ... 4-2 4-16. CALIBRATION ... 4-2 4-18. Power supply Adjustments ... 4-2 4-20. Zero Adjustment . ... 4-3 4-22. Equipment Preparation for Calibration ... 4-3 4-25. Comparator Adjustment (COMP ADJ) ... 4-5 4-27. Positive Full Scale Adjustment (POS CAL) ... 4-5 4-29. Negative Full Scale Adjustment (NEG CAL) ... 4-6 4-31. Linearized Gain Check ... 4-6 4-33. Open Input Detector Circuit Check ... 4-7 4-35. Reference Junction Calibration ... 4-7 440. TROUBLESHOOTING ... . 4-10 5 LISTS OF REPLACEABLE PARTS ... 5-1 5-1. INTRODUCTION ... 5-2 54. HOW TO OBTAIN PARTS ... 5-2 6 OPTIONS AND ACCESSORY INFORMATION ... 6-1 6-1. INTRODUCTION ... 6-1 6-3. CARRYING CASE (C81) ... 6-1 6-5. FRONT PANEL COVER (M03-203-700) ... 6-1 6-7. INSTRUMENT MOUNTING KITS ... 6-1 6-8. Introduction ... 6-1 6-10. Installation Procedures ... 6-1 6-16. THERMOCOUPLE PROBES ... 64 6-19. THERMOCOUPLE TYPE CONVERSION KIT (2100A----K) 64 6-20. Introduction ... 64 6-22. Installation ... 64 6-24. FAHRENHEIT TO CELSIUS CONVERSION KIT (F2CK) . . 64 6-25. Introduction ... 64 6-27. Installation ... 64 6-29. MULTI-POINT SELECTOR SWITCH (2100A-10K) ... 6-5 6-30. Introduction ... 6-5 6-32. Installation ... 6-5 6-34. OPTION -01 BATTERY PACK ... 6-6 6-35. introduction ... 6-6 6-37. Option —01 Operation ... 6-6 643. Option—01 Theory of Operation ... 6-6 645. Option —01 Installation ... 6-6 647. Option —01 Battery Replacement ... 6-7 649. OPTION-02 DIGITAL OUTPUT UNIT ... 6-8 6-50. Introduction ... 6-8 6-52. Option —02 Specifications ... 6-8 6-54. Option —02 Operation ... 6-8 6-59. Option—02 Theory of Operation ... 6-9 6-68. Option—02 Installation ... 6-11 6-70. ANALOG OUTPUT UNIT, OPTION -04 ... 6-12 6-71. Introduction ... 6-12 6-75. Specification ... 6-12 6-77. Installation ... 6-12 6-79. OPERATION ... 6-13 6-81. Theory of Operation ... 6-13 6-87. Calibration ... 6-15 6-89. 2150A MULTIPOINT SELECTOR SWITCH ... 6-17 6-90. Introduction ... 6-17 6-92. Connection for Operation ... 6-17 6-97. Operational Evaluation ... 6-19 6-99. Calibration ... 6-19 7 GENERAL INFORMATION ... 7-1 8 SCHEMATIC DIAGRAMS ... 8-1

Fluke-7696-Manual-Page-1-Picture


Tipo manuale: Manuale di servizio Fluke-10096-Manual-Page-1-Picture
Pagine: 140
Dimensioni: 16.04 Mbytes (16818941 Bytes)
Lingua: Inglese
Revisione: 1
Manuale-ID/numero: 397075
Data: 01 novembre 1975
Qualità: Documento scansionato, tutto leggibile.
Data di aggiunta:
MD5: 33d8cbd8f7e6db7174c412e4b3bff056
Downloads: 45 dal 08 gennaio 2018
Informazioni:

1 INTRODUCTION AND SPECIFICATIONS ... 1-1 1-1. INTRODUCTION ... 14 1-14. SPECIFICATIONS ... 1-3 2 OPERATING INSTRUCTIONS . ... 2-1 24. INTRODUCTION ... 2-1 2-3. SHIPPING INFORMATION ... 2-1 2-6. INPUT POWER ... 2-1 2-9. RACK/PANEL INSTALLATION ... 2-1 2-11. OPERATING FEATURES ... 2-1 2-13. OPERATING NOTES ... 2-5 245. AC Line Connection ... 2-5 247. Fuse Replacement ... 2-5 2-19. Open inputs ... 2-5 2-21. OPERATION ... 2-5 2-22. Models 2100A—03 and 2100A—10 . . ... 2-5 2-24. Model 2100A-06 ... 2-6 2-26. Model 2100A/Model 2150A Set ... 2-6 3 THEORY OF OPERATION ... 3-1 3-1. INTRODUCTION ... 3-1 3-3. OVERALL FUNCTIONAL DESCRIPTION ... . 3-1 3-5. Thermocouple ... 3-2 3-8. Cold Junction Compensation ... 3-2 3-10. Buffer Amplifier ... 3-2 3-12. A/D Converter ... 3-2 3-16. Linearizer ... 3-3 3-19. Display ... 3-3 3-21. CIRCUIT ANALYSIS ... 3-3 3-22. Reference Junction Compensation ... 3-3 3-25. Buffer Amplifier ... 34 3-29. A/D Converter ... 3-5 3-33. Linearizer ... 3-6 348. Summary of Linearizer Operation ... 3-7 4 MAINTENANCE. ... 4-1 4-1. INTRODUCTION ... 4-1 44. GENERAL MAINTENANCE ... 4-1 4-7. Cleaning ... 4-2 4-9. Fuse Replacement ... ' ... 4-2 4-11. Service Tools ... 4-2 4-13. OPERATIONAL EVALUATION ... 4-2 4-16. CALIBRATION ... 4-2 4-18. Power supply Adjustments ... 4-2 4-20. Zero Adjustment . ... 4-3 4-22. Equipment Preparation for Calibration ... 4-3 4-25. Comparator Adjustment (COMP ADJ) ... 4-5 4-27. Positive Full Scale Adjustment (POS CAL) ... 4-5 4-29. Negative Full Scale Adjustment (NEG CAL) ... 4-6 4-31. Linearized Gain Check ... 4-6 4-33. Open Input Detector Circuit Check ... 4-7 4-35. Reference Junction Calibration ... 4-7 440. TROUBLESHOOTING ... . 4-10 5 LISTS OF REPLACEABLE PARTS ... 5-1 5-1. INTRODUCTION ... 5-2 54. HOW TO OBTAIN PARTS ... 5-2 6 OPTIONS AND ACCESSORY INFORMATION ... 6-1 6-1. INTRODUCTION ... 6-1 6-3. CARRYING CASE (C81) ... 6-1 6-5. FRONT PANEL COVER (M03-203-700) ... 6-1 6-7. INSTRUMENT MOUNTING KITS ... 6-1 6-8. Introduction ... 6-1 6-10. Installation Procedures ... 6-1 6-16. THERMOCOUPLE PROBES ... 64 6-19. THERMOCOUPLE TYPE CONVERSION KIT (2100A----K) 64 6-20. Introduction ... 64 6-22. Installation ... 64 6-24. FAHRENHEIT TO CELSIUS CONVERSION KIT (F2CK) . . 64 6-25. Introduction ... 64 6-27. Installation ... 64 6-29. MULTI-POINT SELECTOR SWITCH (2100A-10K) ... 6-5 6-30. Introduction ... 6-5 6-32. Installation ... 6-5 6-34. OPTION -01 BATTERY PACK ... 6-6 6-35. introduction ... 6-6 6-37. Option —01 Operation ... 6-6 643. Option—01 Theory of Operation ... 6-6 645. Option —01 Installation ... 6-6 647. Option —01 Battery Replacement ... 6-7 649. OPTION-02 DIGITAL OUTPUT UNIT ... 6-8 6-50. Introduction ... 6-8 6-52. Option —02 Specifications ... 6-8 6-54. Option —02 Operation ... 6-8 6-59. Option—02 Theory of Operation ... 6-9 6-68. Option—02 Installation ... 6-11 6-70. ANALOG OUTPUT UNIT, OPTION -04 ... 6-12 6-71. Introduction ... 6-12 6-75. Specification ... 6-12 6-77. Installation ... 6-12 6-79. OPERATION ... 6-13 6-81. Theory of Operation ... 6-13 6-87. Calibration ... 6-15 6-89. 2150A MULTIPOINT SELECTOR SWITCH ... 6-17 6-90. Introduction ... 6-17 6-92. Connection for Operation ... 6-17 6-97. Operational Evaluation ... 6-19 6-99. Calibration ... 6-19 7 GENERAL INFORMATION ... 7-1 8 SCHEMATIC DIAGRAMS ... 8-1