Equipment information
California Instruments 800T Oscillator
Manufacturer:
No picture available!
Maybe you can upload a pic for the
California Instruments 800T ?
If you have any other manuals for the
California Instruments 800T you can upload the files here .
Model:
800T
Date:
Category:
Group:
Description:
Variable Frequency Oscillator
Information
The California Instruments 800T Series of Variable Frequency
Oscillator provide a pure sine wave output for driving the
California Instruments Solid State Invertrons, These
oscillators incorporate a unique amplitude regulator circuit
which prevents amplitude overshoot as the frequency of the
Oscillator is varied or as the decade range of the
Oscillator is changed This prevents possible damage to a
sensitive load connected to the output of the Invertron as a
result of excessive output voltage amplitude.
The multi-phase versions of the 800T Series Oscillators are
used to drive two or more Solid State Invertrons connected
so as to provide either two phase or three phase power.
Manual Type:
Service and User Manual
Pages:
102
Size:
2.85 Mbytes (2983404 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
2015 12 20
MD5:
e09c5868eb9eab6c2a039131aff6edd0
Downloads:
574
Information
GENERAL DESCRIPTION
1. 1 INTRODUCTION
1.2 MODEL· NUMBER DESCRIPTION
1.3 GENERAL DESCRIPTION Π i
1.4 ACCESSORY EQUIPMENT ;...
INSTALLATION AND OPERATION P '
2.1 UNPACKING L
2.2 POWER REQUIREMENTS
2. 3 FUSE REQUIREMENTS ;
2.4 ACCEPTANCE TEST PROCEDURE
2. 5 MECHANICAL INSTALLATION and ;
WIRING i
2. 6 OPERATING CONTROLS THEORY OF OPERATION
3. 1 DESCRIPTION OF SINGLE PHASE
OSCILLATOR
3. 2 GENERAL DESCRIPTION OF SINGLE
PHASE TO MULTIPHASE Converter
TEST PROCEDURE
4. 1 GENERAL
4. 2 TEST EQUIPMENT
4. 3 ACCURACY OF THE FREQUENCY DIAL
CALIBRATION and FREQUENCY STABILITY
4» 4 OUTPUT VOLTAGE and AMPLITUDE STABILITY
4. 5 HARMONIC DISTORTION
4. 6 PHASE ACCURACY
CALIBRATION PROCEDURE
5. 1 GENERAL
5. 2 TEST EQUIPMENT REQUIRED
5. 3 MECHANICAL ADJUSTMENT PROCEDURE
for CALIBRATED FREQUENCY DIAL
5. 4 INITIAL CALIBRATION PROCEDURE for WIEN BRIDGE Oscillator
5. 5 EXACT FREQUENCY CALIBRATION PROCEDURE for WIEN BRIDGE
Oscillator ON 20 Hz to 200 Hz RANGE
5. 6 EXACT FREQUENCY CALIBRATION PROCEDURE for WIEN BRIDGE
OSCILLATOR
ON 200 Hz to 2 KHz RANGE
5.7 EXACT FREQUENCY CALIBRATION PROCEDURE for WIEN BRIDGE
Oscillator ON 2 KHz to 20 KHz RANGE
5. 8 FREQUENCY RESPONSE ADJUSTMENTS
5. 9 ABSOLUTE AC OUTPUT VOLTAGE and HARMONIC DISTORTION
5. 10 PHASE ADJUSTMENTS FOR MODEL
800T-20 / 20K~ 1-20 TWO PHASE Oscillator
5. 11 PHASE ADJUSTMENTS FOR MODEL
800T ~ 20 / 2OK - 1 - 3ψΌ THREE PHASE, OPEN Delta Oscillator
5. 12 PHASE ADJUSTMENTS FOR MODEL
800T-20 / 2OK - 1-39 THREE PHASE Oscillator
MAINTENANCE AND TROUBLESHOOTING
6. 1 GENERAL
6. 2 TROUBLESHOOTING
CIRCUIT DIAGRAMS
7, 1 GENERAL
7. 2 REFERENCE DESIGNATIONS REPLACEABLE PARTS
8. 1 GENERAL
8. 2 ORDERING INFORMATION
PARTS LIST APPENDIX A
CODE LIST OF MANUFACTURERS