Informations de l’équipement

Weinmann SOMNOcomfort 2 with SOMNOaqua WM 24450 Respirateur artificiel
Fabricant:
Weinmann
Modèle: SOMNOcomfort 2 with SOMNOaqua WM 24450
Date: 2008
Catégorie: Équipements médicaux et biomédicaux
Groupe: Respirateur artificiel
Description:
Informations:

SOMNOcomfort 2 and SOMNOcomfort 2e are CPAP-Therapy units for the treatment of sleep related respiratory disorders.

Ces manuels sont disponibles pour les équipements ci-dessus :

Type manuel: manuel de réparation Weinmann-10577-Manual-Page-1-Picture
Pages: 44
Taille: 6.02 Mbytes (6307820 Bytes)
Langue: Anglais
Révision:
Numéro d’identification: WM 16988b
Date: 01 février 2008
Qualité: Électronique de documents, numérisation sans, bien lisible.
Télécharger date:
MD5: 3dc4a8a17bebbdae4ba65f2d47f9818f
Téléchargements: 402 depuis 08 mars 2018
Informations:

Introduction ... 3 1. Overview ... 4 2. Description of the equipment ... 8 2.1 Intended use SOMNOcomfort 2 and SOMNOcomfort 2e ... .8 2.2 Intended use SOMNObalance and SOMNObalance e ... .8 2.3 Functional description SOMNOcomfort 2 and SOMNOcomfort 2e ... .9 2.4 Functional description SOMNObalance and SOMNObalance e ... .9 3. Servicing ... . . . 10 3.1 Intervals ... .10 3.2 Filter change ... .11 3.3 Reset service symbol ... .12 3.4 Disposal ... .12 4. Cleaning and disinfecting instructions ... 13 4.1 Cleaning and disinfecting while in use. .13 4.2 Cleaning and disinfecting during repairs ... .13 4.3 Cleaning and disinfecting, new patient .13 4.4 Cleaning and disinfecting the humidifier while in use ... .14 4.5 Cleaning and disinfecting the humidifier, new patient ... .14 5. Final test ... 15 5.1 General ... .15 5.2 Performing the test ... .15 – Preparation – Checking the power supply cable – Checking the power supply – Checking the housing – Checking the control panel and indicators – Checking proper functionality of the therapy unit – Checking proper function of the humidifier 6. Troubleshooting ... 19 7. Repair information and repair instructions . . 21 7.1 General ... .21 7.2 Tools and facilities ... .21 7.3 Sequence of repairs ... .22 7.4 Opening the unit ... .23 7.5 Closing the unit ... .24 7.6 Replacing the main circuit board ... .25 7.7 Replacing the front panel foil ... .26 7.8 Replacing the fuse ... .27 7.9 Replacing the display ... .27 7.10 Replacing the baffle box ... .28 7.11 Replacing the fan ... .30 7.12 Replacing the housing, lower part ... .31 7.13 Replacing the housing, upper part ... .31 8. Replacement parts ... 33 8.1 Replacement parts list ... .33 8.2 Replacement parts required for servicing ... .35 9. Tools, testing equipment and disinfectants . . 36 9.1 Tools ... .36 9.2 Testing equipment ... .36 9.3 Disinfectant ... .36 10. Technical data ... .37 10.2 Specifications for SOMNObalance . . .39 10.3 Pneumatic diagram ... .40 10.4 Electrical block diagram ... .40 10.5 Safety distances for SOMNOcomfort 2 and SOMNOcomfort 2e ... .41 10.6 Safety distances for SOMNObalance and SOMNObalance e ... .41 11. Service record ... . . 42

Weinmann-10577-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics