Equipment information

Good Will GSP-827 Analyzer
Manufacturer:
Model:
GSP-827
Date:
Category:
Group:
Description:
2.7GHz Spectrum Analyzer

Information

The GSP-827 is designed with the features as follows. — Synthesized-based design covering the frequency from 9kHz to 2.7GHz. — Low noise design: -140dBm/Hz noise floor. — 4.5kg light weight and compact size. — 100 traces and setup memories. — ACPR, OCBW, CHBW of power measurement. — 11 ranges of external reference clock (64k~19.2M). — 10 Markers with Peak, Peak Track, ΔMarker, Marker to Center functions. — External and Video Level Trigger with single and continuous modes. — Limit Line and Pass/Fail functions for quickly qualification test. — Spilt Windows extend the measurement flexibility. — Trace functions including Peak Hold, Average and Freeze. — Optional Tracking Generator provides frequency response measurement in one sweep. — Optional filters and Quasi- Peak detection provide EMI test. — GPIB and RS232 Interface for ATE applications. — AC/DC dual modes Power supply and Battery Operations. The fully synthesized-based and low noise designs offer the high RF performance in measurement. The plentiful measurement functions like 10 markers, traces, power measurement, limit line, dual display and trigger make measurement more easily and quickly. The 100 memories, real time calendar and battery operation realize the true portability. 11 ranges of external reference clock offer the synchronization capability to many telecom standards. The optional Tracking Generator offers the frequency response test with the same frequency band. The GPIB and RS232 interfaces allow the connection between the unit and PC. Users can develop their own applications Software. DC 12V Power supply allows user to carry this unit to drive around for frequency monitoring. Chargeable battery pack can support the operation without power cord for 4 hours. With the carrying case, this unit is easy to carry and operate in the filed service. 9k and 120k EMI Filter and quasi-peak detector can perform the EMC test. AM/FM Demodulation provides the demodulated outputs through both headphone and speaker. Kit sets of connector adaptor offers the convenience under different measurement conditions. This unit offers the right combination of highly RF performance, plentiful function, easily operated user Interface and complete options to facilitate measurement in a wide range of application in laboratory as well as in field service usage. This is another example of our dedication to engineering excellence.

show more

User Manual
Manual Type:
User Manual
Pages:
98
Size:
2.75 Mbytes (2880810 Bytes)
Language:
english
Revision:
Manual-ID:
82SP-82700MA
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 05 14
MD5:
5a5f1ff9e176944679955603b11093d9
Downloads:
552

Information

1.0 GENERAL DESCRIPTION AND FEATURES ... 3 2.0 USAGE PRECAUTIONS AND RECOMMENDATIONS ... 4 3.0 PRODUCT OPTION INFORMATION ... 8 4.0 FIRST TIME USE ... 9 4.1 INTERNAL CALIBRATION SIGNAL ... 9 4.2 INSTALL AND UNINSTALL THE BATTERY ... 10 5.0 PANEL DESCRIPTION ... 11 5.1 FRONT PANEL DESCRIPTION ... 11 5.2 REAR PANEL DESCRIPTIONS ... 13 6.0 QUICK USE GUIDE ... 15 6.1 GENERAL DESCRIPTION ... 15 6.2 GUIDE ... 15 6.2.1 FIND THE SIGNAL ... 15 6.2.2 FIND PEAK SIGNAL ... 15 6.2.3 TRACK PEAK SIGNAL ... 16 6.2.4 MAKE CORRECT AMPLITUDE MEASUREMENT ... 16 6.2.5 75Ω SYSTEM MEASUREMENT ... 16 6.2.6 MULTI-MARKER OPERATION ... 16 6.2.7 D ELTA-MARKER OPERATION ... 17 6.2.8 PEAK HOLD, AVERAGE AND FREEZE THE MEASUREMENT ... 17 6.2.9 ACPR MEASUREMENT ... 17 6.2.10 OCBW M EASUREMENT ... 18 6.2.11 PASS/FAIL TEST BY LIMIT LINE ... 18 6.2.12 EDIT THE LIMIT LINE, ... 19 6.2.13 CHANGE RBW, VBW AND SWEEP TIME ... 19 6.2.14 TRIGGER BY INPUT SIGNAL LEVEL ... 19 6.2.15 TRIGGER BY EXTERNALLY STIMULUS SIGNAL ... 20 6.2.16 OBSERVE TWO SWEEPS (EX, 2ND HARMONIC) BY DUAL WINDOWS ... 20 6.2.17 CONFIGURE DISPLAY SETTING ... 20 6.2.18 SAVE MEASUREMENT/SETUP TO MEMORY ... 21 6.2.19 RECALL TRACE/SETUP TO MEMORY ... 21 6.2.20 TURN ON/OFF THE INTERNAL CALIBRATION SIGNAL ... 21 6.2.21 CALENDAR /CLOCK SETTING ... 21 6.2.22 PRESET SYSTEM ... 22 6.2.23 SYSTEM INFORMATION ... 22 6.2.24 SYNCHRONIZED BY EXTERNAL REFERENCE SIGNAL ... 23 6.2.25 SYNCHRONIZE OTHER EQUIPMENTS ... 23 6.2.26 TRACKING Generator OPERATION (OPTION) ... 23 7.0 MENU TREE ... 24 7.1 MAIN FUNCTION ... 24 7.2 MEASUREMENT FUNCTION ... 25 7.3 CONTROL FUNCTION ... 27 7.4 STATE F UNCTION ... 28 8.0 OPERATION ... 31 8.1 MAIN FUNCTIONS ... 31 8.1.1 FREQUENCY FUNCTIONS ... 31 8.1.2 SPAN FUNCTIONS ... 36 8.1.3 A MPLITUDE ... 39 8.2 MEASUREMENT FUNCTIONS ... 43 8.2.1 MARKER ... 43 8.2.2 PEAK SEARCH ... 52 8.2.3 TRACE ... 57 8.2.4 PWR MEASUREMENT ... 61 8.2.5 LIMIT LINE ... 68 8.3 CONTROL FUNCTIONS ... 72 8.3.1 BW ... 72 8.3.2 TRIGGER ... 74 8.3.3 D ISPLAY FUNCTIONS ... 77 8.3.3 D ISPLAY FUNCTIONS ... 78 8.3.4 SAVE/RECALL ... 80 8.4 STATE F UNCTIONS ... 82 8.4.1 CALIBRATION ... 82 8.4.2 SYSTEM ... 83 8.4.3 O PTION ... 87 8.4 POWER CONTROL ... 92 8.5 DIAGNOSIS INFORMATION ON THE DISPLAY ... 92 9.0 SPECIFICATION ...

show more