Description:
Informations:

The METRAVO 4 D is a digitally indicating multimeter featuring liquid crystal display. It offers a plurality of applications in the field of electronics, e.g. in research and development, in production, operation, test rooms and service. It features a constant input resistance of 10 MO 100 pF on all voltage measuring ranges. On 26 measuring ranges, it measures DC and AC voltages up to 650 V, DC and AC currents up to 10 A (temporarily up to 20 A), and resistances up to 20 MQ. Several well-tuned protective means protect the instrument against damage through improper handling and overload: — Overdimensioned precision resistors — Melting fuse in conjunction with protective power diodes — Overvoltage arrester. The rugged design of the METRAVO 4 D, particularly in conjunction with the rubber bag, assures extreme protec- • • tion in case of rough mechanical application. The METRAVO 4 D is fitted with a liquid crystal display i » * (LCD), the high contrast of which is also maintained in environments of very bright light. The instrument operates mains-independent on commercially available Mignon cells. Thanks to the electronic components in LSI technique and the liquid crystal display, current consumption is extraordinarily low so that a long life of a set of batteries is assured. 5 The measuring instrument is constructed to comply with the safety rules of VDE0411 and, if handled with care, assures protection against hazards of electric shocks which is required by VDE 0110 and DIN 40 050.

Ces manuels sont disponibles pour les équipements ci-dessus :

Type manuel: Manuel de l'utilisateur BBCGoerzMetrawatt-6571-Manual-Page-1-Picture
Pages: 27
Taille: 4.02 Mbytes (4216939 Bytes)
Langue: Anglais
Révision:
Numéro d’identification: 3.348.252.03
Date: juin 1978
Qualité: Document scanné, tous les lisible.
Télécharger date:
MD5: c89e5309979c4a64c93ca68b8d13519c
Téléchargements: 458 depuis 07 mars 2015
Informations:

Metravo 4D Operating instructions 1. Description ... 5 1.1 General ... 5 1.2 Theory of operation ... 6 2. Specifications ... 8 3. Overload protection ... 13 3.1 Internal r e s is ta n c e ... 13 3.2 Melting fuse and protective diodes ... 13 3.3 Overvoltage arrester ... 14 4. Operation ... 14 4.1 Start-up ... 14 4.2 Information on using the instrument ... 15 4.3 Voltage measurement ... 17 4.3.1 DC and AC voltages up to 650 V ... 17 4.3.2 DC voltages up to 30 kV ... 17 4.4 Current measurement ... 18 4.4.1 DC and AC currents up to 2 A ... 19 4.4.2 DC and AC currents up to 10 A ... 19 4.4.3 DC and AC currents above 10 A ... 19 4.4.4 AC currents with (split-core) current transformers ... 20 4.5 Measurement of composite voltages and composite currents ... 21 4.5.1 Measurement of DC voltage and DC current with superimposed AC c o m p o n e n t ... 21 4.5.2 Measurement of AC voltage with superimposed DC voltage ... 22 4.5.3 Measurement of AC current with superimposed DC current ... 22 4.6 Resistance m e a s u rem e n t ... 22 5. Maintenance ... 23 5.1 Batteries ... 24 5.2 Melting fuse . ... 24 5.3 Case ... 25 6. Repair and replacement part service ... 25

BBCGoerzMetrawatt-6571-Manual-Page-1-Picture


Type manuel: manuel de réparation BBCGoerzMetrawatt-6575-Manual-Page-1-Picture
Pages: 18
Taille: 400.01 Kbytes (409611 Bytes)
Langue: Allemand
Révision:
Numéro d’identification: 3.338.038.03
Date: avril 1979
Qualité: Document scanné, tous les lisible.
Télécharger date:
MD5: 270f0d1b14eda334fb005042913a6357
Téléchargements: 511 depuis 07 mars 2015
Informations:

Metravo 4D Operating instructions 1. Description ... 5 1.1 General ... 5 1.2 Theory of operation ... 6 2. Specifications ... 8 3. Overload protection ... 13 3.1 Internal r e s is ta n c e ... 13 3.2 Melting fuse and protective diodes ... 13 3.3 Overvoltage arrester ... 14 4. Operation ... 14 4.1 Start-up ... 14 4.2 Information on using the instrument ... 15 4.3 Voltage measurement ... 17 4.3.1 DC and AC voltages up to 650 V ... 17 4.3.2 DC voltages up to 30 kV ... 17 4.4 Current measurement ... 18 4.4.1 DC and AC currents up to 2 A ... 19 4.4.2 DC and AC currents up to 10 A ... 19 4.4.3 DC and AC currents above 10 A ... 19 4.4.4 AC currents with (split-core) current transformers ... 20 4.5 Measurement of composite voltages and composite currents ... 21 4.5.1 Measurement of DC voltage and DC current with superimposed AC c o m p o n e n t ... 21 4.5.2 Measurement of AC voltage with superimposed DC voltage ... 22 4.5.3 Measurement of AC current with superimposed DC current ... 22 4.6 Resistance m e a s u rem e n t ... 22 5. Maintenance ... 23 5.1 Batteries ... 24 5.2 Melting fuse . ... 24 5.3 Case ... 25 6. Repair and replacement part service ... 25