Información sobre equipo

GE Healthcare 3800 Oxímetro de pulso
Fabricante:
GE Healthcare
Modelo: 3800
Fecha: 2005
Categoría: Equipo Médico y Biomédico
Grupo: Oxímetro de pulso
Descripción:
Información:

General description The 3800, 3900, and 3900P pulse oximeters are noninvasive, arterial oxygen saturation and pulse rate monitors. Through the use of a sensor applied to the patient and connected to the monitor, these pulse oximeters measure the absorption of selected wavelengths of light to calculate pulse rate and arterial oxygen saturation. The light generated in the sensor passes through the tissue and is converted into an electronic signal by a photodetector in the sensor. The electronic signal passes to the oximeter and is amplified. Analog and digital signal processing convert the light intensity information into SpO2 and pulse rate values. Both models feature two easy-to-read displays that present patient data and status information. The numeric LEDs (light-emitting diodes) show the SpO2 and pulse rate values. The LCD (liquid crystal display) shows alarm messages, the plethysmographic waveform (or data), and the high and low SpO 2 and pulse rate limit settings. This display also shows the Relative Perfusion Index (PIr®) pulsatile value and menus as appropriate for the monitor.

Estos manuales están disponibles para el equipo anterior:

Tipo de Manual:: Manual de servicio GEHealthcare-10504-Manual-Page-1-Picture
Páginas:: 104
Tamaño:: 898.12 Kbytes (919673 Bytes)
Idioma: Inglés
Revisión:
Número de identificación: 6050-0006-404
Fecha: 01 marzo 2005
Calidad: Documento electrónico, sin análisis, muy bien legible.
Añadir fecha:
MD5: 026ee45fe2f3f6a21fa56b79aa6ca50a
Descargas: 348 desde 04 marzo 2018
Información:

Technical Reference Manual 1/Overview Related information ... 1-1 Technical competence ... 1-1 description ... 1-2 Major components, block interconnect diagram ... 1-2 General subassembly description ... 1-2 Power inlet module ... 1-2 Power supply ... 1-3 Battery ... 1-3 System board ... 1-3 Oximetry board ... 1-3 Sensor filter board ... 1-3 Front panel ... 1-3 3900P Printer ... 1-3 with standards ... 1-4 General safety requirements ... 1-4 Safety checks for software ... 1-4 Electromagnetic compatibility (EMC) ... 1-5 Electromagnetic effects ... 1-8 General ... 1-9 Circuitry ... 1-9 Displays ... 1-9 Audio indicators ... 1-9 Dimensions and weight ... 1-9 Factory settings ... 1-10 Mode switches ... 1-10 Measurement ... 1-11 SpO2 ... 1-11 Pulse rate ... 1-11 PI r pulsatile value ... 1-11 Interfering substances ... 1-11 Sensor emitter wavelength ranges ... 1-11 Alarms ... 1-12 Audible alarms ... 1-12 Alarm limits ... 1-12 Environmental ... 1-12 Electrical ... 1-12 Power ... 1-12 Current leakage ... 1-12 Fuse ... 1-12 Battery ... 1-13 RS-232 connector ... 1-13 Precautions ... 1-14 1.4.1 Warnings ... 1-14 1.4.2 Cautions ... 1-15 Safety guidelines ... 1-16 1.5.1 Cleaning ... 1-16 System board functions ... 2-2 System board data management ... 2-2 Microprocessor ... 2-3 SRAM ... 2-3 Flash memory and software upgrade socket ... 2-3 RS-232 connector interface ... 2-3 Mode switch ... 2-3 Alarm signal and pulse tone generator ... 2-3 Microprocessor supervisor ... 2-3 Audio amplifier ... 2-4 Front panel interface ... 2-4 Background debug ... 2-4 (3900/3900P) Real-time clock ... 2-4 (3900P) Printer interface ... 2-4 System board power management ... 2-4 + 5 V supply ... 2-4 Battery charger ... 2-5 Battery monitor ... 2-5 AC monitor ... 2-5 + VR supply ... 2-5 Power on/standby circuitry ... 2-5 Switch board ... 2-6 Oximetry2.4.12.4.22.4.3board ... 2-7 Oximetry board power supply section ... 2-7 Oximetry board digital section ... 2-7 Microprocessor ... 2-7 Flash memory ... 2-7 SRAM ... 2-7 DAC ... 2-7 Reset circuit ... 2-7 Oximetry board analog section ... 2-8 Detector preamplifier ... 2-8 Interference detect ... 2-9 Multiplexed low-pass filter ... 2-9 Test circuit ... 2-9 Ambient light subtraction ... 2-9 Composite gain stage ... 2-9 Demultiplex and low-pass filter ... 2-9 High-pass filter and multiplex ... 2-9 AC gain stage ... 2-9 Demultiplex low pass ... 2-9 Analog multiplexor and buffer ... 2-10 Multiplexor ... 2-10 LED drive ... 2-11 Sensor monitor ... 2-11 Sensor identification ... 2-11 Passive filtering (sensor filter board or flex cable) ... 2-11 3900P Printer interface ... 2-12 2.6.12.6.2Printer board ... 2-12 Motor driver ... 2-12 Tachometer shaper ... 2-12 Head drivers ... 2-12 ESD protection ... 2-12 Temperature sensor/keypad decoder ... 2-13 Printer button board ... 2-13 3/Test and Upgrade Procedures 3.1 Functionality test ... 3-1 3.1.1 Printer test (3900P) ... 3-3 3.1.2 Diagnostic self-test ... 3-4 3.2 Electrical safety check ... 3-4 3.3 Software upgrade ... 3-5 3.3.1 Remove the cover and identify the system board ... 3-6 3.3.2 (Optional) Check the installed software versions ... 3-6 3.3.3 System software upgrade using the U-LOADER or LOADER chip ... 3-7 3.3.4 System software upgrade using the SYS chip ... 3-9 3.3.5 Oximetry software upgrade (monitors without TruTrak+) ... 3-11 3.3.6 Install the cover and check the installation ... 3-12 4/Troubleshooting 4.1 Messages ... 4-1 4.2 System failure error codes ... 4-5 4.2.1 Nonfatal errors—the system continues running ... 4-5 4.2.2 Fatal errors—the system sounds an alarm tone and halts ... 4-6 4.3 Troubleshooting guide ... 4-8 4.4 3900/3900P TeleOximetry messages and troubleshooting ... 4-12 4.4.1 TeleOximetry status messages ... 4-12 4.4.2 TeleOximetry troubleshooting guide ... 4-14 4.5 Test points ... 4-15 4.5.1 System board test points ... 4-15 4.5.2 Oximetry board test points ... 4-16 Oximetry board in TruTrak+ monitors ... 4-16 Oximetry board in monitors without TruTrak+ ... 4-17 5/Repair and Replacement Procedures 5.1 Oximeter cover ... 5-2 5.1.1 Removing the cover ... 5-2 5.1.2 Replacing the cover ... 5-2 5.2 Front panel assembly ... 5-3 5.2.1 Front panel, remove and disassemble ... 5-3 5.2.2 Sensor filter replacement (board or flex cable) ... 5-4 Sensor filter board ... 5-4 Sensor filter flex cable ... 5-4 5.2.3 Sensor connector replacement ... 5-4 5.2.4 Switch board LCD replacement ... 5-4 5.2.5 Button pad replacement ... 5-4 5.2.6 Switch board replacement ... 5-5 5.2.7 Front panel, reassemble and reinstall ... 5-5 Power-related components ... 5-7 5.3.1 Power supply replacement ... 5-7 5.3.2 Equipotential ground connector replacement ... 5-7 5.3.3 Power inlet module replacement ... 5-8 5.3.4 Fuse replacement ... 5-9 5.3.5 Battery replacement ... 5-10 Speaker replacement ... 5-11 System board replacement ... 5-12 Oximetry board replacement ... 5-14 3900P Printer repair ... 5-15 5.7.1 Printer board replacement ... 5-15 5.7.2 Printer button board replacement ... 5-15 Parts Service kits ... 6-2 Front panel assembly ... 6-6 6.2.1 Front panel components ... 6-6 6.2.2 Front panel assembly drawing (3800) ... 6-7 6.2.3 Front panel assembly drawing (3900/3900P) ... 6-8 Chassis assembly ... 6-9 6.3.1 Chassis components ... 6-9 6.3.2 Chassis assembly drawing ... 6-10 Printer/cover assembly (3900P) ... 6-11 6.4.1 Printer/cover components ... 6-11 6.4.2 Printer/cover assembly drawing ... 6-12 System board ... 6-13 6.5.1 System board components shown ... 6-13 6.5.2 System board layout (all monitors except 3800 without TruTrak+) ... 6-13 6.5.3 System board layout (3800 REF 6051-0000-064 and 6051-0000-163) ... 6-14 Oximetry board ... 6-15 6.6.1 Oximetry board layout (TruTrak+ monitors) ... 6-15 6.6.2 Oximetry board layout (monitors without TruTrak+) ... 6-16 Switch board ... 6-17 Sensor filter flex cable (TruTrak+ monitors) ... 6-18 Sensor filter board (monitors without TruTrak+) ... 6-18 3900P Printer boards ... 6-19 6.9.1 3900P Printer board ... 6-19 6.9.2 3900P Printer button board ... 6-19