Equipment information

Keithley 590 Analyzer
Manufacturer:
Keithley
Model: 590
Date: 1999
Category: Measurement instruments
Group: Analyzer
Description: CV Analyzer
Information:

FEATURES The model 590 CV Analyzer is a sophisticated instrument designed as a complete solution for individuals requiring capacitance and conductance versus voltage measurements in semiconductor testing. The unit can test devices at either 1OOkHz or 1MHz, depending on installed modules. The model 590 1OOk tests at 10OkHz, while the Model 590/1M operates at 1MHz. The Model 59O/1OOk/1M can test at both 1OOkHz and 1MHz. Test voltage for both frequencies is 15mv RMS. The Model 590/100k measures capacitance and conductance on four ranges: 2pF/2µS, 2OpF/20µS, 200pF/200µS, and 2nF/2mS (the optional Model 5904 Input Adapter can extend the 1OOkHz measurement range to 2OnF/20mS). Key model 590 features include: A standard internal +2OV bias source that can generate staircase, pulse train, or DC waveforms. Provision to connect an external bias source of up to +-2OOV DC are also included. Two 450-word internal buffers to store capacitance (C), conductance (G), and bias voltage (V) data taken during testing. Two complete sets of C, G, V~d.ata can be stored; one set can be saved for plotting while another test is being performed. Standard plotter driver Software allows the Model 590 to contro1 an intelligent digital plotter over the IEFE-488 bus, simplifying a variety of different plot types,

These manuals are available for the above equipment:

Manual Type: Service and User Manual Keithley-11283-Manual-Page-1-Picture
Pages: 429
Size: 19.70 Mbytes (20655350 Bytes)
Language: english
Revision: D
Manual-ID/Number: 590-901-01
Date: 01 February 1999
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: 20c95edf8492844552a8c0d0031af582
Downloads: 184 since 23 August 2018
Information:

SECTION 1—GENERAL INFORMATION 1.1 INTRODUCTION ... 1-1 1.2 FEATURES ... 1-1 1.3 WARRANTY INFORMATION ... 1-2 1.4 MANUAL ADDENDA ... 1-2 1.5 SAFETY SYMBOLS AND TERMS ... 1-2 1.6 SPECIFICATIONS ... 1-3 1.7 UNPACKING AND INSPECTION ... 1-3 1.8 USING THE model 580 MANUAL ... 1-3 1.9 OPTIONAL Accessories ... 1-4 SECTION 2—BENCH OPERATION 2.1 INTRODUCTION ... 2-1 2.2 PREPARATION FOR USE ... 2-1 2.2.1 Line Power ... 2-1 2.2.2 Battery Pack Power ... 2-2 2.2.3 Battery Charging ... 2-2 2.3 FRONT PANEL FAMILIARIZATION ... 2-3 2.3.1 Display ... 2-3 2.3.2 Front Panel Controls ... 2-6 2.3.3 Rear Panel Functions ... 2-7 2.3.4 SOURCE/SENSE Terminals and Test Leads ... 2-9 2.4 ERROR AND OPERATIONAL MESSAGES ... 2-9 2.5 OPERATING CONDITIONS ... 2-12 2.5.1 Environmental Conditions ... 2-12 2.5.2 Maximum Allowable Inputs ... 2-12 2.5.3 Warm Up ... 2-12 2.6 BASIC MEASUREMENTS ... 2-12 2.6.1 Connecting Test Leads ... 2-13 2.6.2 Resistance Measurement Procedure ... 2-16 2.6.3 Example Measurements ... 2-16 2.6.4 Polarity ... 2-17 2.6.5 Drive ... 2-18 2.6.6 Relative ... 2-21 2.6.7 Trigger ... 2-21 2.6.8 Dry Circuit Test ... 2-25 2.7 SPECIAL MEASUREMENT CONSIDERATIONS ... 2-26 2.7.1 Thermal EMFs and DRIVE-- ... 2-26 2.7.2 Material Temperature Coefficient ... 2-28 2.7.3 Noisy High Resistance Measurements ... 2-30 2.7.4 Common Mode Voltage Noise ... 2-32 APPENDIX A IEEE-488 Commands ... A-l APPENDIX B IEEE-488 Programs ... B-l

Keithley-11283-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics