Equipment information

Weinmann SOMNOsoft + WM 24600 Ventilator
Manufacturer:
Weinmann
Model: SOMNOsoft + WM 24600
Date: 2007
Category: Medical and Biomedical Equipment
Group: Ventilator
Description:
Information:
                                    SOMNOset is a device for efficient adjustment to CPAP
patients. The device can work on a standalone basis or in
conjunction with the remote control SOMNOadjust or an
extended user interface of the SOMNOsupport software. The
recorded data can also be visualized and evaluated with the
aid of SOMNOsupport. SOMNOset permits titration without the
patient coming to a sleep laboratory. Titration can be
carried out in the patient's familiar surroundings.
SOMNOset generates positive airway pressure (PAP).
SOMNOset may be operated as a self-regulating device. In
that case SOMNOset recognizes respiratory events and varies
the airway pressure accordingly. While the patient is
asleep, the airways are braced by the air pressure generated.
Airway pressure is administered by means of a mask.

These manuals are available for the above equipment:

Manual Type: Service Manual Weinmann-10578-Manual-Page-1-Picture
Pages: 56
Size: 4.69 Mbytes (4921492 Bytes)
Language: english
Revision:
Manual-ID/Number: WM 16824d
Date: 01 January 2007
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: 92efb94f29e63d75d2827f9357cc41c0
Downloads: 160 since 08 March 2018
Information:
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 3
1. Overview . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4
2. Description . . . . . . . . . . . . . . . . . . . . . . .
. . . 6
2.1 Purpose of SOMNOsmart 2 . . . . . . . . .6
2.2 Purpose of SOMNOset . . . . . . . . . . . .6
2.3 Uses SOMNOsoft +. . . . . . . . . . . . . . .7
2.4 Function of SOMNOsmart 2 . . . . . . . . .7
2.5 Function of SOMNOset . . . . . . . . . . . .8
2.6 Functional description of SOMNOsoft +. .9
3. Servicing . . . . . . . . . . . . . . . . . . . . . . . .
. . 10
3.1 Intervals . . . . . . . . . . . . . . . . . . . . . .10
3.2 Filter change. . . . . . . . . . . . . . . . . . .10
– Coarse dust filter
– Fine filter
3.3 Cleaning the device. . . . . . . . . . . . . .11
3.4 Resetting the service symbol . . . . . . . . .12
3.5 Disposal . . . . . . . . . . . . . . . . . . . . .12
4. Hygienic preparation . . . . . . . . . . . . . . . . . 13
4.1 Cleaning and disinfecting after use . . . .13
4.2 Cleaning and disinfection after repair . .13
4.3 Cleaning and disinfecting on change of
patient. . . . . . . . . . . . . . . . . . . . . . .13
4.4 Cleaning and disinfecting the
SOMNOclick/SOMNOclick 300
after use. . . . . . . . . . . . . . . . . . . . . .14
4.5 Cleaning and disinfecting the
SOMNOclick/SOMNOclick 300 on
change of patient . . . . . . . . . . . . . . .14
5. Test the device . . . . . . . . . . . . . . . . . . . . .
. 15
5.1 General . . . . . . . . . . . . . . . . . . . . . .15
5.2 Performing the check . . . . . . . . . . . . .15
– Checking the power cord
– Checking the housing
– Checking display
– Checking pressure and button functions
– Checking OP signal (SOMNOsmart 2
and SOMNOset)
– Checking function of humidifier
6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . 20
7. Repair Information and Instructions . . . . . . . 22
7.1 General . . . . . . . . . . . . . . . . . . . . . .22
7.2 Opening the device . . . . . . . . . . . . . .23
7.3 Closing the device . . . . . . . . . . . . . . .24
7.4 Replace Displayboard . . . . . . . . . . . .25
7.5 Replacing the fascia film . . . . . . . . . . .26
7.6 Changing fuses on the Powerboard . . .26
7.7 Replacing the Powerboard . . . . . . . . .27
7.8 Replacing the Smartboard/Softboard . .30
7.9 Replacing battery on Smartboard or
Softboard. . . . . . . . . . . . . . . . . . . . .31
7.10 Replacing transformer . . . . . . . . . . . . .31
7.11 Replacing the oscillation generator
(SOMNOsmart 2 and SOMNOset only) .34
7.12 Replacing the microphone
(SOMNOsmart 2 and SOMNOset only) .35
7.13 Replacing Smartbox/Comfortbox . . . . .35
7.14 Replacing the fan. . . . . . . . . . . . . . . .36
7.15 Replacing lower part of housing . . . . . .41
7.16 Replacing upper part of housing . . . . . .42
8. Tools, testing equipment and disinfectants . . 44
8.1 Tools . . . . . . . . . . . . . . . . . . . . . . . .44
8.2 Testing equipment and fixtures . . . . . . .44
8.3 Disinfectant. . . . . . . . . . . . . . . . . . . .45
9. Spare parts . . . . . . . . . . . . . . . . . . . . . . .
. 46
9.1 Spare parts list . . . . . . . . . . . . . . . . .46
9.2 Spare parts required for servicing . . . . .48
10. Technical data . . . . . . . . . . . . . . . . . . . . .
. 50
10.1 Specifications . . . . . . . . . . . . . . . . .50
10.2 Pressure-Volume curve. . . . . . . . . . . . .51
10.3 Safety distances . . . . . . . . . . . . . . . .52
11. Repair and service record . . . . . . . . . . . . . . 53