Equipment information

Puritan Bennett LP10 Ventilator
Manufacturer:
Puritan Bennett
Model: LP10
Date: 2004
Category: Medical and Biomedical Equipment
Group: Ventilator
Description: Volume Ventilator
Information:

The Puritan Bennett LP6 Plus and LP10 Volume Ventilators are intended for use in a non-acute care institution or transport, on pediatric and adult patients. It is to be operated in accordance with the product labeling con- tained in this instruction manual. The LP6 Plus and LP10 Volume Ventilators are microprocessor-controlled volume ventilators. They provide continuous respiratory support for patients with respiratory insufficiencies in a skilled nursing facility or hospital, or during transport. Because of the compact design and light weight, the units are highly portable. The ventilators offer a wide range of delivery volumes, inspiratory times, and breathing rates. The physician or the respiratory therapist can set the appropriate ventilation via the controls located in the recessed front panel. The magnetically latched door panel and the control knobs are designed to prevent tampering and accidental resetting.

These manuals are available for the above equipment:

Manual Type: User Manual PuritanBennett-10523-Manual-Page-1-Picture
Pages: 72
Size: 2.38 Mbytes (2490628 Bytes)
Language: english
Revision:
Manual-ID/Number: 068772A-0504
Date: 01 January 2004
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: 8a31247ad07cebcdfdf4b60027edabe5
Downloads: 211 since 06 March 2018
Information:

Clinician’s Manual Introduction ... . ... 1 Purpose of the Manual ... . ... 1 Symbols and definitions ... . ... 2 Warnings and Cautions ... . ... 3 Electrical Interference ... . ... 4 General Description ... . ... 5 Alarm Condition ... . ... 6 Responding to Alarms ... . ... 6 Troubleshooting Guide ... . ... 8 Front Panel ... . ... 10 Upper Section ... . ... 11 Lower Left Section ... . ... 12 Lower Right Section ... . ... 13 Rear Panel ... . ... 14 Operating Controls ... . ... 16 Operating Modes ... . ... 18 Assist/Control ... . ... 18 Assist/Control with Pressure Limit (LP10 Only) ... . ... 18 SIMV (Synchronized Intermittent Mandatory Ventilation) . . . . 18 SIMV with Pressure Limit ... . ... 19 Pressure Cycle ... . ... 19 Standby ... . ... 19 Ventilator Parameters ... . ... 20 Volume ... . ... 20 Breath Rate ... . ... 20 Inspiratory or I-Time ... . ... 20 Breathing Effort ... . ... 22 Pressure Alarms ... . ... 22 Pressure Limit Control (LP10 Only) ... . ... 23 Power Sources ... . ... 26 AC Power ... . ... 26 External Battery 12 Volt DC ... . ... 27 Using a Car Battery ... . ... 27 Internal Battery 12 Volt DC ... . ... 28 Routine Safety Check ... . ... 29 Monthly Safety Check ... . ... 31 Installation ... . ... 34 Mounting or Positioning ... . ... 34 Emergency Vehicle ... . ... 35 Wheelchair ... . ... 36 Power Connections ... . ... 37 General ... . ... 37 AC Power ... . ... 37 External Battery 12 Volt DC ... . ... 38 Battery Performance ... . ... 39 Testing the Batteries ... . ... 40 Special precautions when using an external battery ... . ... 41 Internal Battery 12 Volt DC ... . ... 42 Patient Ventilator Circuit ... . ... 44 Exhalation Manifold ... . ... 46 Humidification ... . ... 46 Short Term ... . ... 46 Extended Use ... . ... 46 Supplemental Oxygen ... . ... 48 Methods ... . ... 48 Accessories ... . ... 50 Positive End Expiratory Pressure (PEEP) ... . ... 51 Pressure Monitoring ... . ... 53 Supplemental Oxygen ... . ... 53 Humidification ... . ... 53 Remote Alarm ... . ... 54 Printer ... . ... 54 Cleaning and Maintenance ... . ... 55 Patient Circuit and Humidifier ... . ... 56 Inlet Air Filter ... . ... 57 Ventilator Surface ... . ... 57 Storage of the Ventilator ... . ... 58 Scheduled Maintenance ... . ... 59 Service Policy ... . ... 60 Specifications ... . ... 61 Limited Warranty ... . ... 64 Keyword Index ... . ... 65

PuritanBennett-10523-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image