Equipment information

SIMS Graseby Capnograph 8400 Pulse Oximeter
Manufacturer:
SIMS Graseby
Model: Capnograph 8400
Date: 2000
Category: Medical and Biomedical Equipment
Group: Pulse Oximeter
Description:
Information:

The Capnograph is a low cost CO2 monitor with oximetry and optional external Printer. It may be used in the hospital or clinical environment, and during emergency land transport. It is not intended for use in the home. It is intended to be used in all critical environments, including ventilatory applications, patient ground transport, EMS (Emergency Medical Services) and anesthesia. The capnography parameter provides end tidal C02 (ET C02) inspired C02 (in CO2) and respiration rate measurements on all patients from pediatric to adult. The oximetry parameter works with all SIMS BCI, Inc. oximetry sensors, providing %Sp02 and pulse rate on all patients from pediatric to adult. The Capnograph permits continuous patient monitoring with adjustable alarm limits as well as visual and auditory alarm signals. It is not intended nor designed to be used as an apnea monitor.

These manuals are available for the above equipment:

Manual Type: Service Manual SIMSGraseby-10512-Manual-Page-1-Picture
Pages: 88
Size: 4.27 Mbytes (4479525 Bytes)
Language: english
Revision: 2
Manual-ID/Number: 1895
Date: 01 September 2000
Quality: Scanned document, reading partly badly, partly not readable.
Upload date:
MD5: c52adb5d9c4a4b9816c132a9b1de9fae
Downloads: 282 since 04 March 2018
Information:

Capnograph Service Manual WARRANTY ... Chapter 1: Introduction 1-1 ... 1-1 ... 1-1 ... 1-2 ... 1-2 ... 1-3 Chapter 2: Product Description ... 1-4 2-1 t ... 2-2 Power Supplies ... ... 2-3 ... 2-3 External Timer Circuitry ... ... 2-3 ... 2-4 ... 2-4 COMET C02 Sensor (Bench) ... ... 2-4 Analog Acquisition Circuitry ... ... 2-4 Display Interface ... ... 2-5 Speaker Drive Circuitry ... ... 2-5 Pump Control ... ... 2-6 Valve Control ... ... 2-6 Serial interface ... ... 2-6 Chapter 3: Pulse Oximetry 3-1 Product Description ... ... 3-1 Theory of Operation ... ... 3-1 ... 3-2 Data Provided to the Host System ... ... 3-2 Data Provided From the Host System (Protocol #1 and Protocol #2) ... ... 3-2 Data Provided From the Host System (Protocol #3) ... ... 3-2 Power Requirements ... ... 3-2 ... 3-2 Serial Communications Specifications ... ... 3-3 ... 3-3 Communication Protocol #1 ... ... 3-3 Communication Protocol #2 ... ... 3-3 Communication Protocol #3 ... ... 3-3 Serial Communication Notes - Protocol #1 and Protocol #2 ... 3-4 Oximeter Transmitted Data - Protocol #1 ... 3-5 Oximeter Transmitted Data - Protocol #2 ... 3-6 Oximeter Received Data - Protocol #1 and Protocol #2 ... 3-7 Serial Communication Notes - Protocol #3 ... 3-7 Slow Data Packet Format ... 3-7 Slow Data Message Format ... J ... 3-8 Fast Data Message Format ... 3-9 Pin Description ... 3-10 Jumper Settings ... 3-11 Probes ... 3-12 Checking Pulse Oximeter Performance ... 3-12 Demonstration Software., ... 3-13 Chapter 4: C02 Theory of Operation___ 4-1 Theoiy of Operation ... 4-1 Measuring C02 ... 4-1 Measuring Respiration Rate ... $ ... 4-2 N20 Compensation ... 4-2 Chapter 5: Pneumatics and C02 Calibration___5-1 Connecting a Non-Recirculating Scavenging System ... 5-1 Checking for Leaks ... 5-2 Calibrating the Capnograph ... : ... 5-2 Low Calibration ... 5-2 Low/High Calibration ... 5-3 Chapter 6: Printer Output__6-1 Printer Setup ... 6-1 Printer Menu ... 6-2 Printer/Output ... 6-3 Output Examples: ... 6-5 Patient Data ... 6-5 Trend Table Data ... 6-5 Chapter 7: Routine Maintenance _____7-1 Charging the Battery ... 7-1 Cleaning and Disinfecting ... 7-1 Maintenance Chart ... 7-2 Long Term Storage ... 7-2 General Cleaning ... 7-3 Performance and Safety Checks ... 7-3 Inspecting the System ... 7-3 Cables and Cords ... 7-3 Chapter 8: Troubles hooting __ 8-1 Troubleshooting the Occlusion Low Priority Alarm ... 8-2 Supplies and Accessories ... 9-1 Ordering Information ... 9-2 Specifications ... 9-3 Capnograph ... 9-3 Respiration Rate ... 9-3 Sp02 ... 9-3 Peripheral Pulse Rate ... / ... 9-4 Pulse Strength ... ! ... 9-4 Alarm Limits Ranges ... 9-4 Serial Output ... 9-5 Power ... 9-5 Physical ... 9-5 Environment ... 9-5 Appendix: Parts Lists, Assembly Drawings___Appendix-1

SIMSGraseby-10512-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image