Equipment information

Ulco Medical Integrus PSV Anesthesia System
Manufacturer:
Ulco Medical
Model: Integrus PSV
Date: 2006
Category: Medical and Biomedical Equipment
Group: Anesthesia System
Description: Anesthesia Workstation
Information:

The Integrus PSV Ventilator is intended for use on humans, from neonate to adult. It must be used as part of an integrated anaesthesia workstation, such as the Ulco Integrus. The Ventilator is micro-processor controlled and usually operates in a time-cycled, gas driven mode. The unit has various ventilation modes such as Volume Controlled Ventilation (VCV) with or without Pressure Limiting, Pressure Controlled Ventilation (PCV), Positive End Expiratory Pressure (PEEP) and Continuous Positive Airway Pressure (CPAP). It also includes several patient- initiated ventilation modes such as Synchronised Intermittent Mandatory Ventilation (SIMV) and Pressure Support Ventilation (PSV). The Integrus PSV can also operate in a closed-loop fashion in the volume controlled modes, by using a unique distal flow sensor. The flow sensor allows the Ventilator to compensate for breathing circuit compliance, leakage and fresh gas flows by measuring precisely the flows into and out of the patient airway. This mode may also be disabled for more classical approach to volume delivery. The display of Integrus PSV is an 8.4” LCD TFT flat panel which gives a very bright display under a variety of lighting conditions and allows the operator to select from a number of different display graphs such as simultaneous display of flow, pressure and volume or the display of respiratory loop graphs.

These manuals are available for the above equipment:

Manual Type: Service Manual Ulco-10286-Manual-Page-1-Picture
Pages: 90
Size: 7.11 Mbytes (7453218 Bytes)
Language: english
Revision: 1.2
Manual-ID/Number: EV9-UM-005
Date: 01 January 2006
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: 88b69fd248f12ecdce384a90056572e5
Downloads: 208 since 10 February 2018
Information:

Ulco-10286-Manual-Page-1-Picture


Manual Type: Service Manual Ulco-10594-Manual-Page-1-Picture
Pages: 33
Size: 1.66 Mbytes (1741779 Bytes)
Language: english
Revision: 1.0
Manual-ID/Number: : EV9-UM-004
Date: 01 January 2005
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: ebe4533b437dc5add6e583d3a9c2fe1e
Downloads: 167 since 09 March 2018
Information:

Introduction ... ... ... ... 6 1.1 About this manual ... 6 1.2 Qualifications for Servicing ... 6 1.3 Units ... 6 Ventilator Overview ... ... ... 7 2.1 Major features ... 7 Description ... ... ... ... 8 3.1 Device Classification ... 8 3.2 Electromagnetic Compatibility ... 8 3.2.1 Electromagnetic Emissions ... 8 3.2.2 Electromagnetic Immunity ... 8 3.2.3 Recommended Separation Distance ... 9 3.2.4 Recommended Separation Distances from Portable and Mobile RF Communication Equipment ... 10 3.3 Workstation Mounting ... 10 Servicing4.1 Overview ... ... ... 11 ... 11 Warnings and Cautions ... 11 Responsibilities of Service Personnel ... 11 Risks ... 11 4.3.1 Explosion ... 11 4.3.2 Electrical ... 11 4.3.3 Contamination ... 11 Preparation and Completion of Service ... 11 4.4.1 Preparation ... 11 4.4.2 Removing the rear access panels ... 11 4.4.3 After Service ... 13 Seals ... 13 Service Intervals and Kits ... 13 4.6.1 Ventilator Routine Preventative Maintenance Intervals ... 14 4.6.2 6 Month Performance Check ... 14 4.6.3 12 Month Service ... 14 4.6.4 36 Month Battery Service ... 14 Tools ... 14 Environmental protection ... 15 Calibration Procedure ... ... ... 16 ... 16 5.1 5.2 5.3 Integrus PSV Ventilator Service Manual Introduction ... 16 5.1.1 Tools to be used ... 16 Method ... 16 Procedures ... 16 5.3.1 Drive Gas Pressure Sensor Calibration ... 17 5.3.2 Drive Flow Sensor Calibration ... 17 5.3.3 Flow Valve Profile Calibration ... 19 5.3.4 Pressure Sensor Calibration ... 20 5.3.5 Commit New Calibration File ... 22 6 7 Service6.1 6.2 6.3 6.4 Procedures ... ... ... 23 ... 23 Access to Ventilator housing ... 23 Removal of Ventilator housing from the anaesthesia machine. ... 25 12 Monthly Service ... 26 6.3.1 EV9000-99 Service kit ... 26 6.3.2 Tools to be used ... 26 6.3.3 Preparation to service Ventilator ... 26 6.3.4 Service Procedure ... 26 6.3.5 Testing ... 28 36 Monthly Service ... 29 6.4.1 EV9000-98 Battery Service kit ... 29 6.4.2 Tools to be used ... 29 6.4.3 Preparation to service Ventilator ... 29 6.4.4 Service Procedure ... 29 6.4.5 Testing ... 30 System Diagrams ... ... ... 31 ... 31 7.1 System Component Diagram ... 31 7.2 Ventilator Pneumatic Block Diagram ... 32 7.3 Ventilator Electronics Block Diagram ... 32 7.4 Ventilator Wiring Diagram ... 33

Ulco-10594-Manual-Page-1-Picture


Add Comment

* Required information
1000
Captcha Image

Comments

No comments yet. Be the first!