Tektronix TDS 700D Oscilloscope
Manufacturer:
No picture available!
Maybe you can upload a pic for the
Tektronix TDS 700D ?
If you have any other manuals for the
Tektronix TDS 700D you can upload the files here .
Model:
TDS 700D
Date:
Category:
Group:
Description:
Digitizing Oscilloscope
Information
The
TDS 500D,
TDS 600B and
TDS 700D oscilloscopes are
portable, four-channel instruments suitable for use in a
variety of test and measurement applications and systems.
User
Interface
Use a combination of front-panel buttons, knobs, and
on-screen menus to control
the many functions of the
Oscilloscope. The front-panel
controls are grouped
according to function: vertical, horizontal, trigger, and
special. Set a function you
adjust often, such as vertical positioning or the time base
setting, directly by its
own front-panel knob. Set a function you change less often,
such as vertical
coupling or horizontal mode, indirectly using a selected menu.
Menus
Pressing one (sometimes two) front-panel button(s), such as
vertical menu,
displays a main menu of related functions, such as coupling
and bandwidth, at
the bottom of the screen. Pressing a main-menu button, such
as coupling,
displays a side menu of settings for that function, such as
AC, DC, or GND
(ground) coupling, at the right side of the screen. Pressing
a side-menu button
selects a setting such as DC.
Indicators
On-screen readouts help you keep track of the settings for
various functions,
such as vertical and horizontal scale and trigger level.
Some readouts use the
cursors or the automatic parameter extraction feature
(called measure) to display
the results of measurements made or the status of the
instrument.
General Purpose Knob
Assign the general purpose knob to adjust a selected
parameter function. More
quickly change parameters by toggling the SHIFT button. Use
the same method
as for selecting a function, except the final side-menu
selection assigns the
general purpose knob to adjust some function, such as the
position of measure-
ment cursors on screen, or the setting for a channel fine gain.
GUI
The user
Interface also makes use of a GUI, or Graphical
User Interface, to make
setting functions and interpreting the display more
intuitive. Some menus and
status are displayed using iconic representations of
function settings, such as
those shown here for full, 250 MHz and 20 MHz bandwidth.
Such icons allow
you to more readily determine status or the available settings.
Signal Acquisition System
The signal acquisition system provides up to four,
full-featured vertical channels
with calibrated vertical scale factors from 1 mV to 10 V per
division, depending
on TDS model. All channels can be acquired simultaneously.
Each of the full-featured channels can be displayed,
vertically positioned, and
offset, and their vertical coupling specified. Some models
can have their
bandwidth limited (250 MHz or 20 MHz). Fine gain can also be
adjusted.
Besides these channels, up to three math waveforms and four
reference wave-
forms are available for display. (A math waveform results
when you specify dual
waveform operations, such as add, on any two channels. A
reference waveform
results when you save a waveform in a reference memory).
Horizontal System
There are three horizontal display modes: main only, main
intensified, and
delayed only. You can select among various horizontal record
length settings.
A feature called “Fit to Screen” allows you to view entire
waveform records
within the 10 division screen area. Waveforms are compressed
to fit on the
screen. See Table 1–2.
Both the delayed only display and the intensified zone on
the main intensified
display may be delayed by time with respect to the main
trigger. Both can be set
to display immediately after the delay (delayed runs after
main mode). The
delayed display can also be set to display at the first
valid trigger after the delay
(delayed-triggerable modes).
The delayed display (or the intensified zone) may also be
delayed by a selected
number of events. In this case, the events source is the
delayed-trigger source.
The delayed trigger can also be set to occur after a number
of events plus an
amount of time.
Manual Type:
Service Manual
Pages:
330
Size:
4.28 Mbytes (4491816 Bytes)
Language:
english
Revision:
Manual-ID:
071-0627-02
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 12 25
MD5:
800d42e6f00f29ebddae10b84749d59c
Downloads:
6795
Information
This manual is divided into sections, such as Specifications
and Theory of
Operation. Further, it is divided into subsections, such as
Product Description
and Removal and Installation Procedures.
Sections containing procedures also contain introductions to
those procedures. Be
sure to read these introductions because they provide
information needed to do
the service correctly and efficiently. The following is a
brief description of each
manual section.
H
Specifications contains a product description of the TDS
500D,
TDS 600C,
TDS 700D and
TDS 714L Oscilloscopes and tables of the
characteristics and
descriptions that apply to it.
H
Operating Information includes general information and
operating instruc-
tions at the level needed to safely power on and service
this
Oscilloscope. A
statement of the service strategy that this manual supports,
and instructions
for shipment of the oscilloscopes are found in this section.
H
Theory of Operation contains circuit descriptions that
support general service
and fault isolation.
H
Performance Verification contains a collection of
procedures for confirming
that these oscilloscopes function properly and meet
warranted limits.
H
Adjustment Procedures contains a collection of procedures
for adjusting
these oscilloscopes to meet warranted limits.
Maintenance contains information and procedures for doing
preventive and
corrective maintenance of these oscilloscopes. Instructions
for cleaning, for
module removal and installation, and for fault isolation to
a module are
found here.
Options contains information on servicing any of the
factory-installed
options that may be present in your
Oscilloscope.
Electrical Parts List contains a statement referring you to
Mechanical
Replaceable Parts, where both electrical and mechanical
modules are listed.
Diagrams contains a block diagram and an interconnection
diagram useful
for isolating failed modules.
Mechanical Parts List includes a table of all replaceable
modules, their
descriptions, and their
Tektronix part numbers.
Manual Type:
Service Manual
Pages:
328
Size:
4.24 Mbytes (4449957 Bytes)
Language:
english
Revision:
Manual-ID:
071-0136-00
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 12 25
MD5:
efe3dd2cac4d28fd0a7932155d33a389
Downloads:
5909
Information
This manual is divided into sections, such as Specifications
and Theory of
Operation. Further, it is divided into subsections, such as
Product Description
and Removal and Installation Procedures.
Sections containing procedures also contain introductions to
those procedures. Be
sure to read these introductions because they provide
information needed to do
the service correctly and efficiently. The following is a
brief description of each
manual section.
Specifications contains a product description of the TDS
500D,
TDS 600B
and
TDS 700D Oscilloscopes and tables of the characteristics
and descrip-
tions that apply to it.
Operating Information includes general information and
operating instruc-
tions at the level needed to safely power on and service
this
Oscilloscope. A
statement of the service strategy that this manual supports,
and instructions
for shipment of the oscilloscopes are found in this section.
Theory of Operation contains circuit descriptions that
support general service
and fault isolation.
Performance Verification contains a collection of procedures
for confirming
that these oscilloscopes function properly and meet
warranted limits.
Adjustment Procedures contains a collection of procedures
for adjusting
these oscilloscopes to meet warranted limits.
Maintenance contains information and procedures for doing
preventive and
corrective maintenance of these oscilloscopes. Instructions
for cleaning, for module removal and installation, and for
fault isolation to a module are
found here.
Options contains information on servicing any of the
factory-installed
options that may be present in your
Oscilloscope.
Electrical Parts List contains a statement referring you to
Mechanical
Replaceable Parts, where both electrical and mechanical
modules are listed.
Diagrams contains a block diagram and an interconnection
diagram useful
for isolating failed modules.
Mechanical Parts List includes a table of all replaceable
modules, their
descriptions, and their
Tektronix part numbers.
Comments