Equipment information

Fluke 6070A Generator
Manufacturer:
Fluke
Model: 6070A
Date: 1988
Category: Measurement instruments
Group: Generator
Description: Synthesized Signal Generator
Information:

THE 6070A/6071A SYNTHESIZED RF SIGNAL Generator 1-7. The John Fluke Models 6070A and 6071A Synthesized RF Signal Generators are designed for use in the calibration laboratory, engineering laboratory, or manufacturing environments. Both models offer extensive modulation capabilities and use phase-locked loop circuitry to generate fully synthesized signals with extremely low discrete spurious, and phase noise. These versatile instruments are intended for both bench and systems use. When the instrument is used in a system, all front panel control functions (except POWER and MOD OUT level) can be controlled via an IEEE-488, 1978, Interface. 1-8. Instrument parameters, such as output frequency and amplitude, can be programmed to specific values or manually adjusted using the Edit Knob (large knob near the lower right corner of the front panel). The Edit Knob is connected to a digital rotary encoder to provide the same continuous manual adjustment capability that an analog tuning control provides, but with the positive positioning of a digital control. The rotary encoder has 25 magnetic detent positions. The user can feel each position of the Edit Knob. 1-9. The major difference between the two models is that the 6071A has twice the output frequency of the 6070A. The output frequency of the 6070A can be selected within 1 Hz over a range from 200 kHz to 519.999999 Mhz (520 MHz). The output frequency of the 6071A can be selected within 1 Hz from 200 kHz to 520 MHz and within 2 Hz from 520 MHz to 1039.999998 MHz (1040 MHz). Both models can produce frequencies outside of the specified ranges, but the performance is not guaranteed. 1-10. The UNCAL annunciator will turn on to indicate that the instrument is operating beyond specified ranges. The synthesized RF signal is available at the front panel RF OUTPUT connector (if the 607XA-830 Rear Panel Output Option is installed, the RF output is available at a rear panel Type N connector). 1-11. Internal frequency reference is a 10 MHz free air timebase (the 607XA-130 Oven Reference Option is available for increased accuracy and stability). This 10 MHz reference can also be phase locked to external references of 1, 2, 2.5, 5, or 10 MHz(0.3 to 4V peak-to~peak sine or square wave) input via a rear panel BNC connector (50 Ohm input impedance, nominally). When an external reference is used, the shift from internal to external is automatic. The 10 MHz reference signal (used as the internal instrument reference) is available as a TTL signal at a rear panel REF OUT connector. 1-12. Below 520 MHz, output level can be selected with a resolution of 0.1 dB over the range of + 19 to -140 dBm (2 V to 22 nV rms) into 50 Ohms. At 520 MHz or above, output level can be selected with a resolution of 0.1 dB over the range of+13 to-140 dBm (I Vto 22 nV rms). Selected level is displayed on the front panel in either dBm or volts (the instrument will convert from one to the other if the units are changed). The internal microprocessor automatically compensates output level for flatness and accuracy although this automatic correction can be disabled (special function 81). 1-13. The RF output signal can be modulated in various combinations of amplitude modulation (AM), frequency modulation (FM), or phase modulation (0M) from internal sources, external sources, or a combination of internal and external sources. Table 1-1 lists all modulation combinations and the possible modulation sources for each combination. Amplitude modulation depth can be selected with a resolution of 0.1 % over the range of 0% to 99.9% (see the specifications for calibrated range). The frequency modulation function allows the output frequency to be deviated while the output frequency is still synthesized unless the DCFM Mode is selected. Maximum index of modulation that can be selected for either FM or 0M depends upon the output frequency and the modulation frequency selected. The internal modulation signal can be made available at the MOD OUT connectors (front and rear panels). An external modulation signal can be either ac or dc coupled through parallel connectors on the rear and front panels (MOD IN connector, 600 Ohm nominal input impedance). External input sensitivity is such that a 1 V peak input signal produces the calibrated modulation. The list of specifications at the end of this section provides detailed information about the modulation characteristics. 1-14. Up to 9 front panel setups can be stored in the internal memory of the standard instrument, but these setups are lost when the instrument is turned off. The 607XA-570 Non-Volatile Memory Option provides 50 memory locations. Since this option is battery powered, front panel setups stored in these 50 locations are not lost when the instrument is turned off. 1-15. Three outputs are available for coordinating the activity of associated devices: sweep analog output, penlift output, and output invalid output. The sweep analog output is available at the front panel SWP OUT connector. This output steps from 0 to 10V as the frequency is swept from the start frequency to the stop frequency. The size of the steps depends upon the sweep width and the sweep increment selected. The penlift output is available at a rear panel BNC connector. This output is a TTL signal that goes high during a sweep retrace and stays high until the next sweep starts. The output valid signal is available at a rear panel BNC connector. This output is a TTL signal that goes high when output frequency, output amplitude, or modulation is potentially unsettled.

These manuals are available for the above equipment:

Manual Type: Service Manual Fluke-10162-Manual-Page-1-Picture
Pages: 50
Size: 2.12 Mbytes (2222424 Bytes)
Language: english
Revision:
Manual-ID/Number: 578054
Date: 01 January 1982
Quality: Scanned document, all readable.
Upload date:
MD5: 043c2f1246a4f43d09e4fb2ba097ec8f
Downloads: 431 since 20 January 2018
Information:

THE 6070A/6071A SERVICE MANUAL 1-5. The information in this, the 6070A/6071A Service Manual, is divided into eight sections: 1 INTRODUCTION Introduces the 6070A/6071A Instruction Manual set and the 6070A/607IA Service Manual. 2 THEORY OF OPERATION Describes the theory of operation under three headings: Software, Theory of Operation, and Circuit Analysis. 3 ACCESS PROCEDURE Describes the procedures necessary to gain access to each major assembly and to gain access to each circuit board inside the instrument. 4 TROUBLESHOOTING Contains troubleshooting information that aids the technician in locating an indicated trouble to a particular assembly. 5 NONROUTINE ADJUSTMENT PROCEDURE Describes Non-routine Adjustment Procedures. These maintenance procedures are usually performed after removal and replacement of circuit board components. 6 LIST OF REPLACEABLE PARTS Contains the list of replaceable parts for the 6070A and the 6071 A. 7 OPTIONS Contains the Options Access Procedures. 8 BACKDATING Contains addenda and manual change information. 1-6. LIST OF RECOMMENDED TEST EQUIPMENT 1-7. The test equipment recommended for servicing the 6070A/6071A is listed in Section 1 of the 6070A/6071A Calibration Manual. If the recommended test equipment is not available, equivalent test equipment can be used. 1-8. 6070A/6071A SPECIFICATIONS 1-9. The 6070A/6071A specifications are contained in Section 1 of the Calibration Manual. 1-10. Fluke SALES AND SERVICE CENTERS 1-11. A list of Fluke Sales and Service Centers is located in Appendix A of the 6070A/6071A Calibration Manual. 1-12. SHIPPING AND SERVICE INFORMATION 1-13. Shipping and service information is contained in Section 2 of the 6070A/6071A Calibration Manual.

Fluke-10162-Manual-Page-1-Picture


Manual Type: Datasheet Fluke-7640-Manual-Page-1-Picture
Pages: 4
Size: 388.57 Kbytes (397899 Bytes)
Language: english
Revision:
Manual-ID/Number:
Date:
Quality: Scanned document, reading partly badly, partly not readable.
Upload date:
MD5: 2c954ed50d8e27cba138511efb1af602
Downloads: 545 since 28 January 2016
Information:

Fluke-7640-Manual-Page-1-Picture


Manual Type: Service Manual Fluke-10160-Manual-Page-1-Picture
Pages: 63
Size: 1.80 Mbytes (1886038 Bytes)
Language: english
Revision:
Manual-ID/Number: 577551
Date: 01 February 1981
Quality: Scanned document, all readable.
Upload date:
MD5: b82ffb8678b07ece0a020fab4ee9f9bd
Downloads: 417 since 20 January 2018
Information:

1-4. THE 6070A/6071A CALIBRATION MANUAL 1-5. The information in this, the 6070A/6071A Calibration Manual is divided into seven sections: 1 INTRODUCTION AND SPECIFICATIONS Introduces the 6070A/6071A Instruction Manual set and the 6070A/6071A Calibration Manual and list the specifications of the instrument and the test equipment required to complete the performance checks and the calibration procedures. 2 SHIPPING AND SERVICE INFORMATION Describes how to ship the instrument and how to get problems corrected. 3 ACCESS PROCEDURES Describes the procedures necessary to gain access to each circuit inside the instrument. 4 GENERAL MAINTENANCE PROCEDURES Describes procedures for cleaning the instrument, for selecting a different line power configuration, and for changing fuses. 5 PERFORMANCE CHECKS Describes procedures to verify proper operation of the instrument. 6 ADJUSTMENT PROCEDURE Describes procedures for making all routine adjustments and describes the procedure used to reprogram the Calibration EPROM. 7 PERFORMANCE CHECKS AND CALIBRATION OF OPTIONS Describes the procedure for completing the performance checks and calibration procedures required by instruments with options installed. Each option has a separate subsection.

Fluke-10160-Manual-Page-1-Picture


Manual Type: User Manual Fluke-8984-Manual-Page-1-Picture
Pages: 30
Size: 983.52 Kbytes (1007121 Bytes)
Language: english
Revision:
Manual-ID/Number:
Date:
Quality: Scanned document, reading partly badly, partly not readable.
Upload date:
MD5: da96205ad69f8018af9a769e221fb7ed
Downloads: 535 since 30 April 2017
Information:

Fluke-8984-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image