Equipment information

Sorensen Company DCS 33-33E Power supply
Manufacturer:
Sorensen Company
Model: DCS 33-33E
Date: 1998
Category: Measurement instruments
Group: Power supply
Description:
Information:

DCS Series power supplies are 1000W supplies designed to provide highly stable, continuously variable output voltage and current for a broad range of development, system and burn-in applications. The series consists of ten models designated by the DCS prefix, followed by the output voltage and current ratings. For example, the model number DCS 60-18E indicates that the unit is rated at 0-60 Vdc and 0-18 Amps while a model DCS 20-50E is rated at 0-20 Vdc and 0-50 Amps. The DCS Series employs high frequency switching regulator technology to achieve high power density and small package size. · Ten models with voltage ranges from 0-8 Vdc to 0-600 Vdc and current outputs from 1.7A to 125A. · 115/230 Vac selectable input voltage, 50-60 Hz single phase, Installation Category II. For Indoor Use. · Simultaneous digital display of both voltage and current. · Ten turn potentiometer voltage and current controls permit high resolution setting of the output voltage and current from zero to the rated output. · Automatic mode crossover into current or voltage mode. · Flexible output configuration: multiple units can be connected in parallel or series to provide increased current or voltage. · High frequency switching technology allows high power density, providing increased power output in a small, light package. · Remote sensing to compensate for losses in power leads. · Adjustable Over-Voltage Protection (OVP) · External TTL, AC or DC shutdown · Remote voltage, resistive, current limit and OVP programming with selectable programming constants. · External indicator signals for remote monitoring of OVP status, local/remote programming status, thermal shutdown, and output voltage and current. · Optional IEEE-488 Interface for complete remote programming and readback capability.

These manuals are available for the above equipment:

Manual Type: User Manual Sorensen-7392-Manual-Page-1-Picture
Pages: 47
Size: 364.25 Kbytes (372997 Bytes)
Language: english
Revision: D
Manual-ID/Number: M360761
Date: 28 April 1998
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: 010c47ce346fe65164c36d05f74543c3
Downloads: 796 since 29 November 2015
Information:

SECTION 1. FEATURES AND SPECIFICATIONS ... 1-1 1.1 DESCRIPTION ... 1-1 1.2 OPERATING MODES ... 1-1 1.3 Power supply FEATURES ... 1-1 1.4 SPECIFICATIONS ... 1-2 1.4.1 Electrical Specifications ... 1-2 1.4.2 Mechanical Specifications ... 1-3 SECTION 2. INSTALLATION AND OPERATING INSTRUCTIONS ... 2-1 2.1 GENERAL ... 2-1 2.2 INITIAL INSPECTION ... 2-1 2.3 INSTALLATION ... 2-1 2.3.1 Input Voltage Selection ... 2-1 2.3.2 Input Line Impedance ... 2-2 2.3.3 Ventilation Requirements ... 2-2 2.3.4 Output Voltage Biasing ... 2-2 2.3.5 Rack Mounting ... 2-2 2.4 INITIAL FUNCTIONAL TESTS ... 2-4 2.5 CONTROLS, CONNECTORS, AND INDICATORS ... 2-5 2.5.1 Front Panel ... 2-5 2.5.2 Rear Panel ... 2-5 2.6 STANDARD OPERATION ... 2-7 2.6.1 Load Conductor Ratings ... 2-7 2.6.2 Load Connection and Grounding ... 2-7 2.6.3 Inductive Loads ... 2-7 2.6.4 Remote Sensing ... 2-8 2.6.5 Negative Output Operation ... 2-8 2.7 SINGLE SUPPLY OPERATION (LOCAL MODE) ... 2-9 2.8 MULTIPLE SUPPLIES ... 2-9 2.8.1 Series Operation ... 2-10 2.8.2 Parallel Operation ... 2-10 2.8.3 Split Supply Operation ... 2-10 2.9 OVER VOLTAGE PROTECTION (OVP) ... 2-10 2.9.1 Front Panel OVP Operation ... 2-11 2.9.2 Remote Programming of OVP With External Voltage Sources ... 2-11 2.9.3 Remote Programming of OVP with an External Resistance ... 2-13 2.9.4 Remote Programming of OVP with External Current Sources ... 2-14 2.9.5 Remote OVP Sensing ... 2-15 2.10 REMOTE ON/OFF ... 2-15 2.10.1 Remote ON/OFF by Contact Closure ... 2-15 2.11 REMOTE PROGRAMMING OF OUTPUT VOLTAGE AND CURRENT LIMIT ... 2-16 2.11.1 Programming With External Voltage Sources ... 2-16 2.11.2 Programming With an External Resistance ... 2-18 2.11.3 Programming With an External Current source ... 2-20 2.12 REMOTE MONITORING AND STATUS INDICATORS ... 2-21 SECTION 3. THEORY OF OPERATION ... 3-1 3.1 POWER CIRCUIT (A2 ASSEMBLY) ... 3-1 3.1.1 Basic Off-Line Switching Regulator Theory ... 3-1 3.1.2 Simplified Full Bridge Converter Theory ... 3-1 3.1.3 Detailed Circuit Description ... 3-3 3.2 METER CIRCUIT (A1 ASSEMBLY) ... 3-8 3.2.1 Voltmeter ... 3-8 3.2.2 Current Meter ... 3-8 SECTION 4. MAINTENANCE, TROUBLESHOOTING, AND CALIBRATION ... 4-1 4.1 GENERAL ... 4-1 4.2 PERIODIC SERVICE ... 4-1 4.3 TROUBLESHOOTING ... 4-1 4.3.1 Preliminary Checks ... 4-1 4.3.2 Internal Troubleshooting ... 4-2 4.4 CALIBRATION ... 4-2 SECTION 5. PARTS LISTS ... 5-1 5.1 GENERAL ... 5-1 5.2 PARTS ORDERING ... 5-1 5.3 PARTS LISTS ... 5-1 SECTION 6. DRAWINGS AND SCHEMATICS ... 6-1 6.1 GENERAL ... 6-1 6.2 DRAWINGS AND SCHEMATICS NOT INCLUDED!

Sorensen-7392-Manual-Page-1-Picture