Equipment information

Kikusui Electronics Corporation PMC18-2A Other
Manufacturer:
Kikusui Electronics Corporation
Model: PMC18-2A
Date: 1994
Category: Measurement instruments
Group: Other
Description: REGULATED DC POWER SUPPLY
Information:

The PMC-A series Regulated DC Power supply is an automatic constant voltage/constant current shift type. It employs a series regulator system and delivers a stable output wish low noise. • The PMC-A series, which has two bright 3-l/2digit LED display meters, displays the output voltage and the output current or their settings. » The potentiometers for the output voltage and current setting are 10 turns wire wound type, allowing high-resolution setting and stable output. • The output switch is an electronic switch. It causes no chattering or noise. It can be controlled from the panel or from a remote place. • The output voltage and current can be remote-controlled by an external analog signal (voltage or Resistor). The PMC-A series can be used as a system component of an automation system with GPIB Interface such as KIKUSUI’s PIA 3200. ThePMC-A series can be used in a wide application field from use in a laboratory for experiment to that on a production line for testing.

These manuals are available for the above equipment:

Manual Type: User Manual Kikusi-7065-Manual-Page-1-Picture
Pages: 34
Size: 861.98 Kbytes (882669 Bytes)
Language: english
Revision:
Manual-ID/Number: Z1 -000-582 IA000791
Date: 1994
Quality: Scanned document, reading partly badly, partly not readable.
Upload date:
MD5: 5314dd6f1a65979aa2b0b17a320f4798
Downloads: 530 since 14 August 2015
Information:

SAFETY SUMMARY ... I CHECK AT UNPACKING ... ffl PACKING FOR RE-SHIPMENT ... IE Chapter 1 GENERAL DESCRIPTION ... 1 Chapter 2 PRECAUTION AND PREPARATION FOR USE ... 1 2.1 Inrush Current ... 1 2.2 Environment ... 2 2.3 Type οΓ Load ... * ... 3 Chapter 3 PANEL DESCRIPTION ... 4 3.1 Front Panel ... * ... - ... 4 3.2 Rear Panel ... * ... 6 Chapter 4 OPERATING METHOD ... 7 4.1 Basic Operation ... *—·** ... 7 4.1.1 Turning the POWER switch on/off ... 7 4.1.2 Setting the output voltage or current, and turning the output on/off ... 7 4.1.3 OVP trip voltage setting ... * ... * ... 7 4.2 Applied Operation ... '·-** ... 8 4.2.1 Remote sensing**···—— ... —* ... 8 4.2.2 Analog remote control ... 8 4.2.3 Series operation and parallel operation ... 12 4.2.4 Master/Slave controlled parallel operation ... * ... 14 Chapter 5 MAINTENANCE AND CALIBRATION ... * ... 15 5.1 Maintenance and Checking ... * ... 15 5.2 Calibration ... - ... * ... 15 5.2.1 Preparation ... * ... 15 5.2.2 Test equipment required ... * ... 16 5.2.3 Calibration setup ·■— ... * ... 16 5.2.4 Calibration procedure ... 17 Chapter 6 SPECIFICATIONS ... ···· 19 6.1 Electrical Specifications ···■· ... 19 6.2 Dimensions ... 21 6.3 Option ... 21

Kikusi-7065-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics