Geräte Informationen

Weinmann MEDUMAT Easy CPR WM 28140 Beatmungsgerät
Hersteller:
Weinmann
Modell: MEDUMAT Easy CPR WM 28140
Datum: 2010
Kategorie: Medizinische und biomedizinische Geräte
Gruppe: Beatmungsgerät
Beschreibung:
Informationen:

MEDUMAT Easy CPR is an automatic oxygen ventilation device (short-term ventilator) with additional inhalation facility. You can use MEDUMAT Easy CPR: • to revive patients at the site of the emergency; • for longer periods in more protracted emergencies; • for short-term O2 inhalation using a ventilation mask. You can use MEDUMAT Easy CPR while transporting patients: • between the various rooms and departments of a hospital; • between the hospital and other premises; • in emergencies; • when transport over considerable distances is planned. MEDUMAT Easy CPR: • is designed to provide controlled ventilation to persons of 10 kg body weight or more; • is used to treat ventilation arrest; • can be preset to parameters that ensure evenly balanced ventilation, provided that the selected maximum ventilation pressure Pmax is not exceeded; • permits breathing-controlled oxygen inhalation in Demand mode; •enables the user to initiate individual ventilation strokes in CPR mode.

Folgende Handbücher sind hierfür verfügbar:

Dokumenttyp: Serviceanleitung Weinmann-10574-Manual-Page-1-Picture
Seitenanzahl: 60
Dateigröße: 5.51 Mbytes (5777157 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: WM67308
Datum: 01 April 2010
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: f1acb4f5c4172ac6ea18311da65c8117
Downloads: 125 seit dem 08 März 2018
Informationen:

Introduction ... 3 1. Overview ... . . . 4 1.1 Special symbols on the Ventilator ... 5 2. Description ... 7 2.1 Uses ... 7 2.2 Ventilation function ... 8 2.3 Demandflow function ... 8 2.4 Patient valve ... 9 2.5 Audio response ... 11 3. Final check ... . 12 3.1 Test material required ... . 12 3.2 Preparation for the final check ... . 13 3.3 Enter device data ... . 13 3.4 Check for leaks and check pressure display ... . 15 3.7 Function check and alarms ... . 15 3.8 Battery voltage ... . 18 3.10 Function check of breath volume at 4.5 bar input pressure and 10 mbar back pressure ... . 19 3.11 Test O2 concentration ... . 20 3.12 Function check of pressure limit ... . 20 3.13 Function check of venting valve without patient valve ... . 21 3.14 Test MEDUtrigger ... . 21 3.15 Test communication socket ... . 22 3.16 Check external condition ... . 22 3.17 Documentation ... . 23 4. Servicing ... . 24 4.1 Intervals and scope ... . 24 4.2 Batteries ... . 25 4.3 Storage ... . 25 5. Troubleshooting ... 26 6. Repair information and instructions ... . 29 6.1 General ... . 29 6.2 Changing the filter in the pressurised gas connection ... . 29 6.3 Open the device ... . 30 6.4 Close the device ... . 32 6.5 Replacing button cell ... . 34 6.6 Changing the speaker ... . 35 6.7 Changing the board ... . 36 6.8 Replacing the pneumatic block ... . 37 6.9 Replacing the 3/2-way magnetic valve . 39 6.10 Calibrating the potentiometer (after changing pneumatic block including potentiometer) ... . 40 6.11 Changing upper part of housing ... . 41 6.12 Changing the fascia film ... . 42 6.13 Replace lower part of housing ... . 43 7. Spare parts ... . . 46 7.1 Spare parts list ... 46 7.2 Service sets ... 48 8. Tools and Test Equipment ... . 50 8.1 General tools ... . 50 8.2 Special tools ... . 50 8.3 Testing equipment ... . 51 9. Technical data ... 52 9.1 Pneumatic / electronic systems ... 53 10. Technical Changes ... 54 11. Repairs and maintenance protocols ... 55

Weinmann-10574-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics