Respironics BiPAP S/T-D Beatmungsgerät
Hersteller:
Respironics
Modell: BiPAP S/T-D
Datum: 1997
Kategorie: Medizinische und biomedizinische Geräte
Gruppe: Beatmungsgerät
Beschreibung:
Informationen:

This BiPAP unit provides bi-level positive airway pressure, through a nasal or nasal / oral mask, to assist patient ventilation. An integral flow transducer senses whether the patient is inhaling or exhaling by constantly monitoring the amount of air flowing through the system. The system then provides the appropriate amount of positive air pressure for the function, i.e., more pressure during inhalation (IPAP), less pressure during exhalation (EPAP). The unit is available in four models: BiPAP S, BiPAP S/T, BiPAP S-D, BiPAP S/T-D. The BiPAP S unit offers two modes of operation: • CPAP (Continuous Positive Airway Pressure) - When the control is set to either IPAP or EPAP, the unit provides continuous pressure at the level you set for that function. • SPONTANEOUS - The unit cycles between inhalation (IPAP) and exhalation (EPAP) levels as triggered by patient breathing. The BiPAP S/T offers four modes of operation: • CPAP (Continuous Positive Airway Pressure) - When the control is set to either IPAP or EPAP, the unit provides continuous pressure at the level you set for that function. • SPONTANEOUS - The unit cycles between inhalation (IPAP) and exhalation (EPAP) levels as triggered by patient breathing. • SPONTANEOUS/TIMED - As with the SPONTANEOUS mode, the unit cycles between IPAP and EPAP levels as sensed from patient breathing, but if the patient does not inhale within a preset time interval, the unit cycles to IPAP. The time interval is determined by the BPM (breaths per minute) setting on the control panel. • TIMED - The unit cycles between IPAP and EPAP levels at preset time intervals, determined by the BPM and % IPAP (percent of breath cycle spent in IPAP settings on the control panel). The BiPAP S-D unit offers the same operating modes as the BiPAP S, but all functions can be controlled by a Detachable Control Panel (DCP). In addition, the following DC analog output signals are provided for a recorder or oscilloscope: • P (Pressure) - The signal from the internal pressure transducer indicates IPAP and EPAP levels (in cm H20 at the measure point in the patient circuit). • Vt (Estimated Tidal Volume) - Signal from the internal flow transducer indicates volume of air (in liters) inhaled or exhaled with each breath during quiet breathing. • V (Total Flow Rate) - The signal from the internal flow transducer indicates total air flow rate (in L/ min) through the unit to the patient circuit. Total air flow consists of the air flow necessary to satisfy circuit leaks (V|eak), and patient breathing (Vest). he BiPAP S/T-D unit offers the same operating modes as the BiPAP S/T, but all functions can be controlled by a DCP. In addition, it provides the same recorder output signals ( VT,7tot Vest and P) as the BiPAP S-D. °' * ’ The Airway Pressure Monitor is designed to supplement patient monitoring during ventilation with the BiPAP S/T-D System. Its purpose is to notify medical personnel and/or user of undesirably LOW (as in a disconnect situation) or HIGH pressures at a specific point in the breathing cycle.

Folgende Handbücher sind hierfür verfügbar:

Dokumenttyp: Serviceanleitung Respironics-10531-Manual-Page-1-Picture
Seitenanzahl: 165
Dateigröße: 5.38 Mbytes (5646473 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: 1006389
Datum: 01 Januar 1997
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: d3dde04c00b0f8a20bd34b25ade6a74d
Downloads: 125 seit dem 06 März 2018
Informationen:

Chapter 1 Warnings, Cautions, and Notes 1.1 Warnings ... 1-1 1.2 Cautions ... 1-3 1.3 Notes ... 1-3 Chapter 2 BiPAP System 2.1 Identifying the BiPAP System Unit ... 2-1 2.2 BiPAP System Specifications ... 2-3 2.3 System Description ... 2-6 2.4 System Components ... 2-7 Chapter 3 Controls and Set-up 3.1 Controls ... 3-1 3.1.1 Front Panel ... 3-1 3.1.2 Rear Panel Controls ... 3-2 3.2 Setting Up the BiPAP System ... 3-5 3.3 Detachable Control Panel (DCP) (Optional) ... 3-8 3.4 DCP Set-up ... 3-9 Chapter 4 Maintenance 4.1 Maintenance Schedule ... 4-1 4.2 Maintenance Procedures ... 4-3 4.2.1 Recording the Hours on the Time Meter ... 4-3 4.2.2 Verifying theVoltage Selector Switch Setting ... 4-3 4.2.3 Changing the Fuses ... 4-3 4.2.4 Test Unit Control Functions ... 4-4 4.2.5 Notes to Maintenance Procedures ... 4-4 4.2.6 Cleaning the BiPAP 20 ... 4-5 4.2.7 Changing the Filter ... 4-6 Chapter 5 Troubleshooting 5.1 Troubleshooting ... 5-1 5.1.1 Troubleshooting Chart ... 5-2 5.1.2 Power Switch Wiring ... 5-7 5.1.3 Motor Control Board (MCB) Checks ... 5-7 5.1.4 Blower Assembly Checks ... 5-8 5.1.5 Transformer Checks ... 5-9 Chapter 5 continued 5.1.6 Valve Checks ... 5-9 f 5.1.7 BiPAP Control Board (BCB) Checks ... 5-9 5.1.8 Blower Pressure Check ... 5-9 5.1.9 Temperature Guidelines ... 5-10 5.2 Wiring Diagram ... 5-11 Chapter 6 Repair and Replacement 6.1 Repair Information ... 6-1 6.1.1 Preparing the Unit for Service ... 6-2 6.1.2 Releasing Cable Clips ... 6-3 6.1.3.Releasing Hose Clamps ... 6-3 6.2 Replacement Guide ... 6-4 6.2.1 Wraparound Replacement ... 6-4 6.2.2 Blower Assembly Replacement ... 6-5 6.2.3 Motor Controller Board (MCB) Replacement ... :. 6-11 6.2.4 BiPAP Control Board (BCB) Replacement ... 6-13 6.2.5 Transformer Replacement ... 6-16 6.2.6 Muffler Replacement ... 6-20 6.2.7 Valve Replacement ... 6-23 6.2.8 Flow Pick-Up Tube Replacement ... 6-25 6.2.9 Main Power Switch Replacement ... 6-26 6.2.10 Front End Cap Replacement ... 6-27 6.2.11 Blower Shock Mount Replacement ... 6-30 6.2.12 Flex Connector Replacement ... 6-34 6.2.13 AC Inlet Connector w/Fuse Drawer Replacement ... 6-37 6.2.14 Control Knob Replacement ... 6-39 6.2.15 Voltage Selector Switch Replacement ... 6-40 6.2.16 Time Meter Replacement ... 6-42 6.2.17 Pressure Port Replacement (S-D and S/T-D Models Only) ... 6-44 6.2.18 Crowbar Fuse Replacement ... 6-46 6.2.19 Latch Replacement ... 6-47 6.2.20 Top Plate Replacement ... 6-48 6.2.21 Side Panel Replacement ... 6-50 6.2.22 Bottom Plate Replacement ... 6-52 Chapter 7 System Adjustment and Final 7.1 Requirements ... 7-1 7.1.1 Equipment ... 7-1 7.1.2 Data Sheet ... 7-1 7.1.3 Required Tests ... 7-2 7.1.4 Test Sequence ... 7-2 7.2 Initial Equipment Set-up ... 7-3 7.3 Blower Pressure Adjustment (all units) ... 7-5 7.3.1 Test Equipment Set-up ... 7-5 Chapter 7 continued 7.3.2 BiPAP Set-up ... 7-5 7.3.3 Test Procedure ... 7-5 7.4 Flow Transducer Calibration (all units) ... 7-7 7.4.1 Test Equipment Set-up ... 7-7 7.4.2 BiPAP Set-up ... 7-7 7.4.3 Test Procedure for Transducer 332046 ... 7-8 7.4.4 Test Procedure for Transducer 332290 ... 7-9 7.5 Valve Control Calibration (all units) ... 7-10 7.5.1 Test Equipment Set-up ... 7-10 7.5.2 BiPAP Set-up ... 7-10 7.5.3.Test Procedure ... 7-10 7.6 Pressure Monitor Calibration (S/T-D and S-D units) ... 7-11 7.6.1 Test Equipment Set-up ... 7-11 7.6.2 BiPAP Set-up ... 7-11 7.6.3 Test Procedure ... 7-11 7.7 Pressure Monitor Calibration (Using the DCP) ... : ... 7-12 7.7.1 Test Equipment Set-Up ... 7-12 7.7.2 BiPAP Set-Up ... 7-12 7.7.3 Test Procedure ... 7-12 7.8 Blocked and Unblocked Watts (all units) ... 7-13 7.8.1 Test Equipment Set-up ... 7-13 7.8.2 BiPAP Set-up ... 7-13 7.8.3 Test Procedure ... 7-13 7.9 Trigger Level Verification (all units) ... 7-14 7.9.1 Test Equipment Set-up ... 7-14 7.9.2 BiPAP Set-up ... 7-14 7.9.3 Test Procedure ... 7-14 7.10 Overnight Run/Morning Check ... 7-15 7.10.1 BiPAP S and S-D Set-up ... 7-15 7.10.2 BiPAP S/T and S/T-D Set-Up ... 7-15 7.103 Test Procedure ... 7-15 7.11 System Final Test ... 7-15 7.12 Spontaneous Mode Verification (all units) ... 7-16 7.12.1 Test Equipment Set-up ... 7-16 7.12.2 BiPAP Set-up ... 7-16 7.12.3 Test Procedure ... 7-16 7.13 Spontaneous/Timed Mode Verification (S/T & S/T-D) ... 7-18 7.13.1 Test Equipment Set-up ... 7-18 7.13.2 BiPAP Set-up ... 7-18 7.13.3 Test Procedure ... 7-18 7.14 Timed Mode Verification (S/T and S/T-D) ... 7-20 7.14.1 Test Equipment Set-up ... 7-20 7.14.2 BiPAP Set-up ... 7-20 7.14.3 Test Procedure ... 7-20 Chapter 7 continued 7.15 Verify Zero Function (S-D and S/T-D) ... 7-22 f 7.15.1 Test Equipment Set-up ... 7-22 7.15.2 BiPAP Set-up ... 7-22 7.15.3 Test Procedure ... 7-22 7.16 Verify Calibrate Function (S-D and S/T-D) ... ‘ ... 7-23 7.16.1 Test Equipment Set-up ... 7-23 7.16.2 BiPAP Set-up ... 7-23 7.16.3 Test Procedure ... 7-23 7.17 DCP Verification (S-D and S/T-D) ... 7-24 7.17.1 Test Equipment Set-up ... 7-24 7.17.2 BiPAP Set-up ... 7-24 7.17.3 Test Procedure ... 7-24 7.18 Corrective Actions ... 7-25 Chapter 8 Parts List and Exploded Views 8.1 Wraparound Assembly ... 8-1 8.2 Exploded View ... 8-2 8.3 Exploded View—Foam Panels ... 8-4 Appendix A Required Tools and Equipment A.l Service Tools ... A-l A.2 Service Supplies ... A-2 A.3 Acceptable Electronic Test Equipment ... A-3 A.3.1 Flowmeter ... A-3 A.3.2 Oscilloscope ... A-3 A.3.3 Digital Manometer ... A-3 A.3.4 Wattmeter ... A-3 Appendix B Data Sheets ... B-l Appendix C BiPAP Screening Procedure C.l BiPAP Screening Procedure ... C-l Appendix D DC Operation ... D-l Appendix E BiPAP 20 System Schematics E.l Wiring Diagram ... E-l E.2 Schematic Statement ... E-l Appendix F Changes ... F-

Respironics-10531-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics