Geräte Informationen

Mindray BeneView T8 Überwachungssystem
Hersteller:
Mindray
Modell: BeneView T8
Datum: 2006
Kategorie: Medizinische und biomedizinische Geräte
Gruppe: Überwachungssystem
Beschreibung: Patient Monitor
Informationen:

This patient monitor is intended to be used for monitoring, displaying, reviewing, storing and transferring of multiple physiological parameters including ECG, heart rate (HR), respiration (Resp), temperature (Temp), SpO2, pulse rate (PR), non-invasive blood pressure (NIBP), invasive blood pressure (IBP), cardiac output (C.O.), carbon dioxide (CO2), oxygen (O2 ), anesthetic gas (AG), impedance cardiograph (ICG), bispectral index (BIS) and respiration mechanics (RM) of single adult, pediatric and neonatal patients. ST-segment monitoring and C.O. monitoring are restricted to adult patients only. The ICG is only for use on adult patients who meet the following requirements: height: 122 to 229 cm, weight: 30 to 159 kg. 12-lead ECG and BIS monitoring are not intended for neonatal patients. This monitor is to be used in healthcare facilities by clinical professionals or under their direction. It is not intended for helicopter transport, hospital ambulance, or home use.

Folgende Handbücher sind hierfür verfügbar:

Dokumenttyp: Serviceanleitung Mindray-10232-Manual-Page-1-Picture
Seitenanzahl: 144
Dateigröße: 3.73 Mbytes (3911831 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: 6800-20-50661
Datum: 01 Oktober 2006
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: 582d1768dc3db75dc1d6a89346df57e9
Downloads: 176 seit dem 05 Februar 2018
Informationen:

This manual provides detailed information about the assembling, dissembling, testing and troubleshooting of the equipment to support effective troubleshooting and repair. It is not intended to be a comprehensive, in-depth explanation of the product architecture or technical implementation. Observance of the manual is a prerequisite for proper equipment maintenance and prevents equipment damage and personnel injury. This manual is based on the maximum configuration; Therefore, some contents may not apply to your monitor.

Mindray-10232-Manual-Page-1-Picture


Dokumenttyp: Bedienungsanleitung Mindray-10227-Manual-Page-1-Picture
Seitenanzahl: 290
Dateigröße: 3.36 Mbytes (3527136 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: 6800-20-50657
Datum: 01 September 2006
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: d849b27150243561f93fdfc6de0d10ef
Downloads: 191 seit dem 04 Februar 2018
Informationen:

1 Safety ... 1-1 1.1 Safety Information ... 1-1 1.1.1 Dangers ... 1-2 1.1.2 Warnings ... 1-2 1.1.3 Cautions ... 1-3 1.1.4 Notes ... 1-3 1.2 Equipment Symbols ... 1-4 1.3 Reference Literature ... 1-5 2 The Basics ... 2-1 2.1 Monitor Description ... 2-1 2.1.1 Intended Use ... 2-1 2.1.2 Contraindications ... 2-1 2.1.3 Components ... 2-1 2.2 Main Unit ... 2-2 2.2.1 Front View ... 2-2 2.2.2 Side View ... 2-4 2.2.3 Bottom View ... 2-4 2.2.4 Rear View ... 2-5 2.3 Satellite Module Rack ... 2-7 2.4 Modules ... 2-8 2.4.1 Plug-In Modules ... 2-8 2.4.2 Multi-Parameter Module ... 2-9 2.5 Display Screen ... 2-10 2.6 QuickKeys ... 2-12 3 Basic Operations ... 3-1 3.1 Installation ... 3-1 3.1.1 Unpacking and Checking ... 3-2 3.1.2 Environmental Requirements ... 3-3 3.2 Getting Started ... 3-4 3.2.1 Turning Power On ... 3-4 3.2.2 Starting Monitoring ... 3-4 3.3 Disconnecting from Power ... 3-5 3.4 Using a Mice ... 3-6 3.5 Using Keyboards ... 3-7 3.6 Using the Touchscreen ... 3-7 3.7 Using the Main Menu ... 3-8 3.8 Using a CF Storage Card ... 3-9 3.9 Changing General Settings ... 3-10 3.9.1 Setting up a Monitor ... 3-10 3.9.2 Changing Language ... 3-10 3.9.3 Adjusting the Screen Brightness ... 3-10 3.9.4 Showing/Hiding the Help ... 3-11 3.9.5 Setting the Date and Time ... 3-11 3.9.6 Adjusting Volume ... 3-12 3.10 Default Configurations ... 3-13 3.10.1 Restoring the Factory Default Configuration ... 3-13 3.10.2 Saving Current Configuration as User Default Configuration ... 3-13 3.10.3 Loading a User Default Configuration ... 3-14 3.10.4 Deleting a User Default Configuration ... 3-14 4 Managing Patients ... 4-1 4.1 Admitting a Patient ... 4-1 4.2 Quick Admitting a Patient ... 4-2 4.3 Editing Patient Information ... 4-3 4.4 Discharging a Patient ... 4-3 4.5 Connecting to a Central Monitoring System ... 4-4 5 User Screens ... 5-1 5.1 Tailoring Your Screens ... 5-1 5.1.1 Setting the Waveform Sweep Mode ... 5-1 5.1.2 Changing the Wave Line Size ... 5-1 5.1.3 Changing Measurement Colors ... 5-1 5.1.4 Selecting Measurement Parameters ... 5-2 5.1.5 Substituting or Adding a Wave ... 5-2 5.1.6 Changing Screen Layout ... 5-2 5.2 Viewing Minitrends ... 5-3 5.2.1 Having a Split-Screen View of Minitrends ... 5-3 5.2.2 Changing Minitrend Length ... 5-4 5.2.3 Changing a Parameter for Viewing ... 5-4 5.3 Viewing oxyCRG ... 5-5 5.4 Viewing Other Patients ... 5-6 5.4.1 Care Group ... 5-6 5.4.2 Understanding the View Other Patient Window ... 5-6 5.5 Understanding the Big Numerics Screen ... 5-8 6 Alarms ... 6-1 6.1 Alarm Categories ... 6-1 6.2 Alarm Levels ... 6-2 6.3 Alarm Indicators ... 6-3 6.3.1 Alarm Lamp ... 6-3 6.3.2 Alarm Message ... 6-3 6.3.3 Flashing Numeric ... 6-4 6.3.4 Audible Alarm Tones ... 6-4 6.3.5 Alarm Status Symbols ... 6-4 6.4 Alarm Tone Configuration ... 6-5 6.4.1 Changing the Alarm Volume ... 6-5 6.4.2 Switching the Alarm Sound On/Off ... 6-5 6.4.3 Setting the Interval between Alarm Sounds ... 6-5 6.5 Using Alarms ... 6-6 6.5.1 Switching Individual Measurement Alarms On/Off ... 6-6 6.5.2 Setting the Alarm Level ... 6-6 6.5.3 Adjusting Alarm Limits ... 6-6 6.5.4 Recording Alarms Automatically ... 6-7 6.6 Pausing Alarms ... 6-8 6.7 Silencing the System ... 6-8 6.8 Latching Alarms ... 6-8 6.9 Clearing Technical Alarms ... 6-9 6.10 When an Alarm Occurs ... 6-9 7 Monitoring ECG/Resp ... 7-1 7.1 Introduction ... 7-1 7.2 Safety ... 7-2 7.3 Preparing to Monitor ECG ... 7-3 7.3.1 Preparing the Patient and Placing the Electrodes ... 7-3 7.3.2 Choosing AHA or IEC Lead Placement ... 7-4 7.3.3 ECG Lead Placements ... 7-4 7.3.4 Checking Paced Status ... 7-7 7.4 Understanding the ECG Display ... 7-8 7.5 Changing ECG Settings ... 7-9 7.5.1 Accessing ECG Menus ... 7-9 7.5.2 Choosing the Alarm Source ... 7-9 7.5.3 Choosing a 5-Lead ECG Display Screen ... 7-9 7.5.4 Changing the ECG Filter Settings ... 7-10 7.5.5 Switching the Notch Filter On or Off ... 7-10 7.5.6 Switching Defibrillator Synchronization On/Off ... 7-11 7.5.7 Changing ECG Wave Settings ... 7-11 7.5.8 Choosing the Heart Rate Source ... 7-12 7.6 About ST Monitoring ... 7-13 7.6.1 Switching ST On and Off ... 7-13 7.6.2 Changing the ST Alarm Limits ... 7-14 7.6.3 Adjusting ST Measurement Points ... 7-14 7.7 About Arrhythmia Monitoring ... 7-15 7.7.1 Switching Arrhythmia Analysis On and Off ... 7-15 7.7.2 Changing Arrhythmia Alarm Settings ... 7-15 7.7.3 Initiating Arrhythmia Relearning Manually ... 7-15 7.7.4 Automatic Arrhythmia Relearn ... 7-15 7.7.5 Reviewing Arrhythmia Events ... 7-16 7.8 12-Lead ECG Monitoring ... 7-17 7.8.1 Entering the 12-lead ECG Analysis Program ... 7-17 7.8.2 12-Lead ECG Analysis ... 7-18 7.8.3 Reviewing 12-Lead ECG Analysis Results ... 7-19 7.9 Monitoring Respiration (Resp) ... 7-20 7.9.1 Understanding the Resp Display ... 7-20 7.9.2 Placing Resp Electrodes ... 7-20 7.9.3 Choosing the Respiration Lead ... 7-21 7.9.4 Changing the Apnea Alarm Delay ... 7-21 7.9.5 Changing Resp Detection Mode ... 7-21 7.9.6 Changing Resp Wave Settings ... 7-22 8 Monitoring SpO2 ... 8-1 8.1 Introduction ... 8-1 8.2 Safety ... 8-2 8.3 Identifying SpO2 Modules ... 8-3 8.4 Applying the Sensor ... 8-3 8.5 Changing SpO2 Settings ... 8-4 8.5.1 Accessing SpO2 Menus ... 8-4 8.5.2 Adjusting the Desat Alarm Limit ... 8-4 8.5.3 Setting SpO2 Sensitivity ... 8-4 8.5.4 Monitoring SpO2 and NIBP Simultaneously ... 8-5 8.5.5 Sat-Seconds Alarm Management ... 8-5 8.5.6 Setting the Pulse Rate ... 8-7 8.5.7 Changing the Speed of the Pleth Wave ... 8-7 8.6 Masimo Information ... 8-8 8.7 Nellcor Information ... 8-8 9 Monitoring NIBP ... 9-1 9.1 Introduction ... 9-1 9.2 Safety ... 9-2 9.3 Measurement Limitations ... 9-2 9.4 Measurement Methods ... 9-3 9.5 Setting Up the NIBP Measurement ... 9-3 9.5.1 Preparing to Measure NIBP ... 9-3 9.5.2 Starting and Stopping Measurements ... 9-3 9.5.3 Correcting the Measurement if Limb is not at Heart Level ... 9-4 9.5.4 Enabling NIBP Auto Cycling and Setting the Interval ... 9-4 9.5.5 Starting a STAT Measurement ... 9-4 9.6 Understanding the NIBP Numerics ... 9-5 9.7 Changing NIBP Settings ... 9-6 9.7.1 Choosing NIBP Alarm Source ... 9-6 9.7.2 Displaying NIBP Measurements ... 9-6 9.7.3 Setting the Pressure Unit ... 9-7 9.8 Assisting Venous Puncture ... 9-7 9.9 Resetting NIBP ... 9-7 9.10 NIBP Leakage Test ... 9-7 9.11 NIBP Accuracy Test ... 9-8 9.12 Calibrating NIBP ... 9-9 10 Monitoring Temp ... 10-1 10.1 Introduction ... 10-1 10.2 Safety ... 10-1 10.3 Making a Temp Measurement ... 10-2 10.4 Understanding the Temp Display ... 10-2 10.5 Setting the Temperature Unit ... 10-2 11 Monitoring IBP ... 11-1 11.1 Introduction ... 11-1 11.2 Safety ... 11-1 11.3 Setting Up the Pressure Measurement ... 11-2 11.4 Understanding the IBP Display ... 11-3 11.5 Changing IBP Settings ... 11-4 11.5.1 Changing a Pressure for Monitoring ... 11-4 11.5.2 Defining Pressure Labels ... 11-4 11.5.3 Choosing the Pressure Alarm Source ... 11-4 11.5.4 Setting the Pressure Unit ... 11-5 11.5.5 Setting Up the IBP Wave ... 11-5 11.6 Zeroing the Transducer ... 11-5 11.7 Making the Pressure Calibration ... 11-6 12 Monitoring Cardiac Output ... 12-1 12.1 Introduction ... 12-1 12.2 Understanding the C.O. Display ... 12-2 12.3 Influencing Factors ... 12-2 12.4 Setting Up the C.O. Measurement ... 12-3 12.5 Measuring the Blood Temperature ... 12-6 12.6 Changing C.O. Settings ... 12-6 12.6.1 Setting the Temperature Unit ... 12-6 12.6.2 Setting the Interval between Measurements ... 12-6 13 Monitoring Carbon Dioxide ... 13-1 13.1 Introduction ... 13-1 13.2 Identifying CO2 Modules ... 13-2 13.3 Preparing to Measure CO2 ... 13-3 13.3.1 Using a Sidestream CO2 Module ... 13-3 13.3.2 Using a Microstream CO 2 Module ... 13-4 13.3.3 Using a Mainstream CO2 Module ... 13-5 13.4 Changing CO2 Settings ... 13-6 13.4.1 Accessing CO2 Menus ... 13-6 13.4.2 Changing the Operating Mode ... 13-6 13.4.3 Setting the Pressure Unit ... 13-6 13.4.4 Setting up CO2 Compensations ... 13-7 13.4.5 Humidity Compensation for Side/Microsctream CO2 Readings ... 13-7 13.4.6 Setting the Apnea Alarm Delay ... 13-8 13.4.7 Choosing a Time Interval for Peak-Picking ... 13-8 13.4.8 Setting up the CO2 Wave ... 13-8 13.4.9 Setting the Automatic Standby Time ... 13-9 13.5 Troubleshooting the Sidestream CO2 Sampling System ... 13-9 13.6 Removing Exhaust Gases from the System ... 13-9 13.7 Zeroing the Sensor ... 13-10 13.7.1 For Sidestream and Microstream CO2 Modules ... 13-10 13.7.2 For Mainstream CO2 Modules ... 13-10 13.8 Calibrating the Sensor ... 13-11 13.9 Oridion Information ... 13-11 14 Monitoring AG ... 14-1 14.1 Introduction ... 14-1 14.2 Identifying AG Modules ... 14-1 14.3 Understanding the AG Display ... 14-2 14.4 Connecting AG Accessories ... 14-3 14.5 Changing AG Settings ... 14-4 14.5.1 Accessing AG Menus ... 14-4 14.5.2 Selecting an Anesthetic Gas for Monitoring ... 14-4 14.5.3 Setting the Apnea Alarm Delay ... 14-4 14.5.4 Changing the Sample Flow Rate ... 14-4 14.5.5 Setting up the O2 Compensation ... 14-5 14.5.6 Changing the Operating Mode ... 14-5 14.5.7 Setting the Automatic Standby Time ... 14-5 14.5.8 Setting up the AG Wave ... 14-5 14.6 Troubleshooting ... 14-6 14.6.1 When the Gas Inlet is Blocked ... 14-6 14.6.2 When Internal Occlusions Occurs ... 14-6 14.7 Removing Exhaust Gases from the System ... 14-6 15 Monitoring ICG ... 15-1 15.1 Introduction ... 15-1 15.2 Safety ... 15-1 15.3 Understanding ICG Parameters ... 15-2 15.3.1 Measured Parameters ... 15-2 15.3.2 Calculated Parameters ... 15-2 15.4 Understanding the ICG Display ... 15-3 15.5 ICG Limitations ... 15-4 15.6 Preparing to Monitor ICG ... 15-4 15.6.1 Preparing the Patient ... 15-4 15.6.2 Placing ICG Sensors ... 15-5 15.6.3 Setting up the Patient Information ... 15-5 15.7 Changing ICG Settings ... 15-6 15.7.1 ICG Averaging ... 15-6 15.7.2 Selecting Secondary Parameters ... 15-6 15.7.3 Checking Sensors ... 15-6 15.7.4 Changing the ICG Wave Speed ... 15-6 16 Monitoring BIS ... 16-1 16.1 Introduction ... 16-1 16.2 Safety Information ... 16-2 16.3 Understanding the BIS Display ... 16-3 16.4 Setting up the BIS Measurement ... 16-4 16.5 Continuous Impedance Check ... 16-5 16.6 Cyclic Impedance Check ... 16-6 16.7 BIS Sensor Check Window ... 16-7 16.8 Choosing the BIS Smoothing Rate ... 16-8 16.9 Setting up the EEG Wave ... 16-8 17 Monitoring RM ... 17-1 17.1 Introduction ... 17-1 17.2 Safety Information ... 17-3 17.3 Preparing to Monitor RM ... 17-4 17.4 Understanding the RM Display ... 17-5 17.5 Changing RM Settings ... 17-6 17.5.1 Accessing RM Menus ... 17-6 17.5.2 Setting the Apnea Alarm Delay ... 17-6 17.5.3 Selecting TV or MV for Display ... 17-6 17.5.4 Selecting Flow or Vol Waveform for Display ... 17-6 17.5.5 Changing the Wave Sweep Speed ... 17-6 17.5.6 Changing the Wave Scale ... 17-7 17.6 Understanding the Respiratory Loops ... 17-8 17.7 Zeroing the RM Module ... 17-9 17.8 Calibrating the Flow Sensor ... 17-9 18 Freezing Waveforms ... 18-1 18.1 Freezing Waveforms ... 18-1 18.2 Viewing Frozen Waveforms ... 18-1 18.3 Unfreezing Waveforms ... 18-2 18.4 Recording Frozen Waveforms ... 18-2 19 Review ... 19-1 19.1 Accessing Respective Review Windows ... 19-1 19.2 Reviewing Graphic Trends ... 19-2 19.3 Reviewing Tabular Trends ... 19-4 19.4 Reviewing NIBP Measurements ... 19-6 19.5 Reviewing Alarms ... 19-7 19.6 Reviewing Waveforms ... 19-8 20 Calculations ... 20-1 20.1 Introduction ... 20-1 20.2 Dose Calculations ... 20-2 20.2.1 Performing Calculations ... 20-2 20.2.2 Selecting the Proper Drug Unit ... 20-3 20.2.3 Titration Table ... 20-4 20.3 Oxygenation Calculations ... 20-5 20.3.1 Performing Calculations ... 20-5 20.3.2 Entered Parameters ... 20-6 20.3.3 Calculated Parameters ... 20-6 20.4 Ventilation Calculations ... 20-7 20.4.1 Performing Calculations ... 20-7 20.4.2 Entered Parameters ... 20-8 20.4.3 Calculated Parameters ... 20-8 20.5 Hemodynamic Calculations ... 20-9 20.5.1 Performing Calculations ... 20-9 20.5.2 Entered Parameters ... 20-10 20.5.3 Calculated Parameters ... 20-11 20.6 Renal Calculations ... 20-12 20.6.1 Performing Calculations ... 20-12 20.6.2 Entered Parameters ... 20-13 20.6.3 Calculated Parameters ... 20-13 20.7 Understanding the Review Window ... 20-14 21 Recording ... 21-1 21.1 Using a Recorder ... 21-1 21.2 Overview of Recording Types ... 21-2 21.3 Starting and Stopping Recordings ... 21-3 21.4 Setting up the Recorder ... 21-4 21.4.1 Accessing the Record Setup Menu ... 21-4 21.4.2 Selecting Waveforms for Recording ... 21-4 21.4.3 Setting the Realtime Recording Length ... 21-4 21.4.4 Setting the Interval between Timed Recordings ... 21-4 21.4.5 Changing the Recording Speed ... 21-4 21.4.6 Switching Gridlines On or Off ... 21-5 21.4.7 Clearing Recording Tasks ... 21-5 21.5 Loading Paper ... 21-6 21.6 Removing Paper Jam ... 21-7 21.7 Cleaning the Recorder Printhead ... 21-7 22 Other Functions ... 22-1 22.1 Marking Events ... 22-1 22.2 Analog Output ... 22-1 22.3 Nurse Call ... 22-2 23 Batteries ... 23-1 23.1 Overview ... 23-1 23.2 Conditioning the Batteries ... 23-2 23.3 Checking the Batteries ... 23-3 23.4 Installing the Batteries ... 23-3 23.5 Recycling the Batteries ... 23-4 24 Care and Cleaning ... 24-1 24.1 General Points ... 24-1 24.2 Cleaning ... 24-2 24.3 Disinfecting ... 24-2 25 Maintenance ... 25-1 25.1 Safety Checks ... 25-1 25.2 Service Tasks ... 25-2 25.3 Checking Monitor and Module Information ... 25-3 25.4 Calibrating ECG ... 25-3 25.5 Calibrating the Touchscreen ... 25-3 25.6 Calibrating CO2 ... 25-4 25.7 Calibrating AG ... 25-5 25.8 Setting up IP Address ... 25-6 25.9 Entering/Exiting Demo Mode ... 25-6 26 Accessories ... 26-1 26.1 ECG Accessories ... 26-2 26.2 SpO2 Accessories ... 26-3 26.3 NIBP Accessories ... 26-5 26.4 Temp Accessories ... 26-6 26.5 IBP/ICP Accessories ... 26-6 26.6 C.O. Accessories ... 26-7 26.7 CO2 Accessories ... 26-7 26.8 AG Accessories ... 26-9 26.9 ICG Accessories ... 26-9 26.10 BIS Accessories ... 26-9 26.11 RM Accessories ... 26-9 26.12 Others ... 26-10 A Product Specifications ... A-1 A.1 Monitor Safety Specifications ... A-1 A.2 Physical Specifications ... A-4 A.3 Hardware Specifications ... A-5 A.4 Data Storage ... A-8 A.5 Measurement Specifications ... A-9 B EMC ... B-1 C Factory Defaults ... C-1 C.1 Patient Demographics ... C-1 C.2 Alarm Setup ... C-1 C.3 Screen Setup ... C-1 C.4 ECG Setup ... C-2 C.5 Resp Setup ... C-3 C.6 SpO2 Setup ... C-4 C.7 NIBP Setup ... C-5 C.8 Temp Setup ... C-5 C.9 IBP Setup ... C-6 C.10 C.O. Setup ... C-7 C.11 CO2 Setup ... C-8 C.12 AG Setup ... C-9 C.13 ICG Setup ... C-10 C.14 BIS Setup ... C-11 C.15 RM Setup ... C-12 D Alarm Messages ... D-1 D.1 Physiological Alarm Messages ... D-2 D.2 Technical Alarm Messages ... D-3 E Symbols and Abbreviations ... E-1 E.1 Symbols ... E-1 E.2 Abbreviations ... E-3

Mindray-10227-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image