Geräte Informationen

Wiltron 5436A Test Set
Hersteller:
Wiltron
Modell: 5436A
Datum: 1992
Kategorie: Messgeräte
Gruppe: Test Set
Beschreibung: SCALAR MEASUREMENT SYSTEMS
Informationen:

The 54XXA is a microprocessor controlled scalar measurement system. This system is used to make scalar (magnitude) transmission, reflection, and absolute power measurements. A typical model is shown in Figure 1-1 (facing page). All measurement functions are selectable by using the front panel keys and controls together with the display screen menus. Section III describes this mode of operation. All 54XXA front panel control functions (except POWER on/off) are programmable via the IEEE–488 Interface bus (GPIB). This function can be ordered as an option on all models (refer to paragraph 1-6). Remote operation of the 54XXA using GPIB commands is described in the GPIB User’s Guide for the 54XXA Series Scalar Measurement Systems that is located behind the Supplements/Options tab at the rear of this manual. The measurement frequency range of the 54XXA is determined by: · The range of the internal signal source of the particular model. · The external SWR Autotester and/or detector used with the 54XXA.

Folgende Handbücher sind hierfür verfügbar:

Dokumenttyp: Serviceanleitung Wiltron-6262-Manual-Page-1-Picture
Seitenanzahl: 185
Dateigröße: 1.54 Mbytes (1613976 Bytes)
Sprache: Englisch
Revision: A
Dokument-ID/Nummer: 10410-00123
Datum: August 1992
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: 65dc69cab1e4de16dab6a0ac802a92ae
Downloads: 972 seit dem 17 August 2014
Informationen:

Chapter 1 — General Service Information This section provides a general description of series 54XXA Scalar Measurement Systems, system serial numbers, and frequency ranges. It explains the level of maintenance covered in this manual and provides preventative maintenance procedures. It also contains static-sensitive component handling precautions and a list of recommended test equipment. Chapter 2 — Replaceable Parts This Chapter lists all replaceable subassemblies and components for all 54XXA models. It explains the Wiltron exchange assembly program and provides parts ordering information. Chapter 3 — Troubleshooting This chapter provides information for troubleshooting 54XXA Scalar Measurement Systems. The troubleshooting information and fault location tables contained in this chapter support fault isolation down to a replaceable subassembly. Chapter 4 — Functional Overview This chapter provides descriptions of the functional operation of the major assemblies contained in 54XXA series Scalar Measurement Systems. The operation of all major circuit blocks is described so that the reader may better understand the function of each major assembly as part of the overall operation of the 54XXA. Chapter 5 — Removal and Replacement Procedures This chapter describes how to gain access to the major 54XXA assemblies and parts for troubleshooting or replacement. Chapter 6 — Adjustments This chapter provides adjustment procedures for all models of series 54XXA Scalar Measurement Systems. These procedures are used after replacement or repair of one or more critical subassemblies, or as indicated by the Performance Verification Procedures (which are contained in Section V of the Series 54XXA Scalar Measurement Systems Operation Manual). Appendix A — RF Detector Diode Replacement Procedures This appendix contains rf detector diode replacement procedures for 5400-71XXX and 560-7XXX series RF Detectors. 54XXA MM i Appendix B — Fabrication of RF Detector Simulator This appendix contains information for fabricating the T1492 RF Detector Simulator test aid. This test aid is used in the calibration procedures contained in Chapter 6. Appendix C — Fabrication of Dummy Thermistor Test Aids This appendix contains information for fabricating the T38300 Dummy Down Converter Thermistor and the T38301 Dummy Directional Coupler Thermistor test aids. These test aids are used in the Temperature Compensation Adjustment Procedure for series 54XXA Scalar Measurement Systems contained in Chapter 6.

Wiltron-6262-Manual-Page-1-Picture


Dokumenttyp: Bedienungsanleitung Wiltron-6263-Manual-Page-1-Picture
Seitenanzahl: 100
Dateigröße: 1.96 Mbytes (2055909 Bytes)
Sprache: Englisch
Revision: E
Dokument-ID/Nummer: 10410-00118
Datum: Dezember 1994
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: fe0629c5eae863d3842f69947156ed9e
Downloads: 845 seit dem 17 August 2014
Informationen:

Chapter 1 — General Service Information This section provides a general description of series 54XXA Scalar Measurement Systems, system serial numbers, and frequency ranges. It explains the level of maintenance covered in this manual and provides preventative maintenance procedures. It also contains static-sensitive component handling precautions and a list of recommended test equipment. Chapter 2 — Replaceable Parts This Chapter lists all replaceable subassemblies and components for all 54XXA models. It explains the Wiltron exchange assembly program and provides parts ordering information. Chapter 3 — Troubleshooting This chapter provides information for troubleshooting 54XXA Scalar Measurement Systems. The troubleshooting information and fault location tables contained in this chapter support fault isolation down to a replaceable subassembly. Chapter 4 — Functional Overview This chapter provides descriptions of the functional operation of the major assemblies contained in 54XXA series Scalar Measurement Systems. The operation of all major circuit blocks is described so that the reader may better understand the function of each major assembly as part of the overall operation of the 54XXA. Chapter 5 — Removal and Replacement Procedures This chapter describes how to gain access to the major 54XXA assemblies and parts for troubleshooting or replacement. Chapter 6 — Adjustments This chapter provides adjustment procedures for all models of series 54XXA Scalar Measurement Systems. These procedures are used after replacement or repair of one or more critical subassemblies, or as indicated by the Performance Verification Procedures (which are contained in Section V of the Series 54XXA Scalar Measurement Systems Operation Manual). Appendix A — RF Detector Diode Replacement Procedures This appendix contains rf detector diode replacement procedures for 5400-71XXX and 560-7XXX series RF Detectors. 54XXA MM i Appendix B — Fabrication of RF Detector Simulator This appendix contains information for fabricating the T1492 RF Detector Simulator test aid. This test aid is used in the calibration procedures contained in Chapter 6. Appendix C — Fabrication of Dummy Thermistor Test Aids This appendix contains information for fabricating the T38300 Dummy Down Converter Thermistor and the T38301 Dummy Directional Coupler Thermistor test aids. These test aids are used in the Temperature Compensation Adjustment Procedure for series 54XXA Scalar Measurement Systems contained in Chapter 6.

Wiltron-6263-Manual-Page-1-Picture


Dokumenttyp: Bedienungsanleitung Wiltron-6264-Manual-Page-1-Picture
Seitenanzahl: 66
Dateigröße: 657.53 Kbytes (673313 Bytes)
Sprache: Englisch
Revision: C
Dokument-ID/Nummer: 10410-00119
Datum: Oktober 1993
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: 527cd688bd02d246bc53b3cabf308d27
Downloads: 804 seit dem 17 August 2014
Informationen:

Chapter 1 — General Service Information This section provides a general description of series 54XXA Scalar Measurement Systems, system serial numbers, and frequency ranges. It explains the level of maintenance covered in this manual and provides preventative maintenance procedures. It also contains static-sensitive component handling precautions and a list of recommended test equipment. Chapter 2 — Replaceable Parts This Chapter lists all replaceable subassemblies and components for all 54XXA models. It explains the Wiltron exchange assembly program and provides parts ordering information. Chapter 3 — Troubleshooting This chapter provides information for troubleshooting 54XXA Scalar Measurement Systems. The troubleshooting information and fault location tables contained in this chapter support fault isolation down to a replaceable subassembly. Chapter 4 — Functional Overview This chapter provides descriptions of the functional operation of the major assemblies contained in 54XXA series Scalar Measurement Systems. The operation of all major circuit blocks is described so that the reader may better understand the function of each major assembly as part of the overall operation of the 54XXA. Chapter 5 — Removal and Replacement Procedures This chapter describes how to gain access to the major 54XXA assemblies and parts for troubleshooting or replacement. Chapter 6 — Adjustments This chapter provides adjustment procedures for all models of series 54XXA Scalar Measurement Systems. These procedures are used after replacement or repair of one or more critical subassemblies, or as indicated by the Performance Verification Procedures (which are contained in Section V of the Series 54XXA Scalar Measurement Systems Operation Manual). Appendix A — RF Detector Diode Replacement Procedures This appendix contains rf detector diode replacement procedures for 5400-71XXX and 560-7XXX series RF Detectors. 54XXA MM i Appendix B — Fabrication of RF Detector Simulator This appendix contains information for fabricating the T1492 RF Detector Simulator test aid. This test aid is used in the calibration procedures contained in Chapter 6. Appendix C — Fabrication of Dummy Thermistor Test Aids This appendix contains information for fabricating the T38300 Dummy Down Converter Thermistor and the T38301 Dummy Directional Coupler Thermistor test aids. These test aids are used in the Temperature Compensation Adjustment Procedure for series 54XXA Scalar Measurement Systems contained in Chapter 6.

Wiltron-6264-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics