Geräte Informationen

Keithley 179A Digital Multimeter
Hersteller:
Keithley
Modell: 179A
Datum: 1982
Kategorie: Messgeräte
Gruppe: Digital Multimeter
Beschreibung: TRMS Multimeter
Informationen:

INTRODUCTION The Model 179A is a precision 4 1/2 digit TRMS multimeter useful for measurement of AC and DC voltage, AC and DC current and resistance. Ranges and accuracies are listed in the detailed specifications which precede this section. Ranges and functions are selected with front panel push buttons. The decimal point is also positioned by the selected range push button. Polarity of the measured signal is automatically displayed. FEATURES The Model 179A includes the following features: • TRMS AC measurement capability gives waveform-insensitive measurement accuracy to applications such as solid-state regulator design, measurement of power transformer input currents and capacitor ripple currents. • AC and DC CURRENT ranges allow continuous measurements of up to 15A or periodic measurement up to 20A. • 10µV AC and DC sensitivity • HI-LO Ohms. In the HI mode, enough voltage can be applied to semiconductors to turn them on for a test. LO can be used for in-circuit measurements without turning on semiconductor junctions. Full-scale compliance voltage is 2V on HI, 200mV on LO. • 1kV protection on Ω. 1000V overload protection on ohms eliminates accidental damage due to improper function selection. • Optional BCD output. The Model 1792 Isolated BCD Output may be ordered and is field installable. • Optional IEEE-488 data output. The Model 1793 IEEE-488 Interface can be ordered with the unit, or can be easily field-installed with a screwdriver, It is powered internally from the instrument. With the Interface and any of the low cost controllers now on the market, it is possible to set up an economical, automated test system that saves the time of manually recording, transcribing and entering large amounts of measurement data.

Folgende Handbücher sind hierfür verfügbar:

Dokumenttyp: Datenblatt Keithley-5588-Manual-Page-1-Picture
Seitenanzahl: 1
Dateigröße: 293.91 Kbytes (300961 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer:
Datum:
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: d64be8aa8b201c0d57080ba414bf8b03
Downloads: 264 seit dem 07 März 2014
Informationen:

Keithley-5588-Manual-Page-1-Picture


Dokumenttyp: Service- und Bedienungsanleitung Keithley-11208-Manual-Page-1-Picture
Seitenanzahl: 33
Dateigröße: 1.63 Mbytes (1707701 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: 32430
Datum: 01 Januar 1982
Qualität: Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
MD5: 377c8a8067a6a52434bb43bb26662d3c
Downloads: 79 seit dem 21 August 2018
Informationen:

SECTION 1 GENERAL INFORMATION 1.1 Introduction ... 1.2 Features ... 1.3 Warranty Information ... 1.4 Manual Addenda ... - ... 1.5 Safety Symbols and Terms ... 1.6 Unpacking and Inspection ... - ... 1.7 Optional Accessories ... 1.8 Specifications ... 1-2 SECTION 2 OPERATION 2.1 Preparation for Use ... 2-1 2.1.1 Line Power ... 2-1 2.1.2 Battery Pack Power ... 2-1 2.1.3 Battery Charging ... 2-1 2.2 Operating Instructions ... 2-1 2.2.1 Environmental Conditions ... 2-1 2.2.2 Front Panel Familiarization ... 2-1 2.3 DMM Measurements - ... 2-3 2.3.1 DC Voltage Measurement ... 2-3 2.3.2 TRMS AC Voltage Measurement ... 2-4 2.3.3 Resistance (HI Measurement ... . 2-4 2.3.4 Current Measurement (DC or TRMS ACI ... 2-4 2.3.5 AC and DC Measurement ... 2-5 SECTION 3 PERFORMANCE VERIFICATION 3.1 Introduction ... 3-1 3.2 Environmental Conditions ... 3-1 3.3 Recommended Test Equipment ... 3-1 3.4 Performance Verification Procedure ... 3-1 3.5 Initial Conditions ... 3-1 3.6 DC Volts Verification ... 3-1 3.7 AC Volts Verification ... 3-2 3.8 Resistance Verification ... 3-2 3.9 DC Current Verification ... 3-2 3.10 AC Current Verification ... 3-2 SECTION 4 THEORY OF OPERATION 4.1 Introduction ... 4-1 4.2 Overall Operation ... 4-1 4.2.1 Signal Conditioning ... 4-1 4.2.2 Ohms Conversion ... 4-1 4.2.3 A/D Converter ... 4-1 4.3 Attenuation ... 4-2 4.3.1 DC Volts ... 4-2 4.3.2 AC Volts ... 4-2 4.4 AC Conversion ... 4-2 4.5 Ohms Conversion ... 4-2 4.5.1 Range Selection ... 4-2 4.5.2 1! Circuit ... 4-2 4.6 A/D Converter ... 4-3 4.6.1 Auto-Zero ... 4-3 4.6.2 Signal-Integrate . . . . ... 4-3 4.6.3 Reference-Integrate ... 4-3 4.6.4 Reference Voltages ... 4-3 4.7 Display ... 4-4 4.8 Current Measurements ... 4-4 4.9 AC Power Supply ... 4-4 4.10 Model 1788 Battery Pack ... 4-4 4.10.1 Battery Charging Circuit ... 4-5 4.10.2 Battery Operation and Shutdown Circuit ... 4-5 SECTION 5 MAINTENANCE 5.1 Introduction ... 5-1 5.2 Calibration Procedure ... 5-1 5.2.1 Recommended Test Equipment ... 5-1 5.2.2 Environmental Conditions ... 5-1 5.2.3 Calibration Shield Installation ... 5-1 5.2.4 Calibration Adjustments ... 5-1 5.3 Battery Pack (Model 17881 Installation ... 5-2 5.4 Troubleshooting ... 5-2 5.4.1 Troubleshooting Procedure ... 5-3 5.5 Special Handling of Static Sensitive Devices 5-3 5.6 Battery Charge Voltage Adjustments ... 5-3 5.7 Fuse Replacement ... 5-4 SECTION 6 REPLACEABLE PARTS 6.1 Introduction ... 6.2 Replaceable Parts ... 6.3 Ordering Information ... 6.4 Factory Service ... 6.5 Component Location Drawings . 6.6 Schematic Diagram ...