Equipment information
Kikusui Electronics Corporation AVM15 Digital multimeter
Manufacturer:
No picture available!
Maybe you can upload a pic for the
Kikusui Electronics Corporation AVM15 ?
If you have any other manuals for the
Kikusui Electronics Corporation AVM15 you can upload the files here .
Model:
AVM15
Date:
2001
Category:
Group:
Description:
AC Voltmeter
Information
These AC Voltmeters are capable of measuring AC voltages of
10 Hz - 500 kHz. The response characteristics of the
pointers are of mean-value response.
The scales are calibrated with root-mean—square values for
sinusoidal waveform inputs.. Range selection of the
Dual-pointer Voltmeters (Models AVM23, AVM25, AVM23R,, and
AVM25R) can be made with, the two channels directly linked
together or with the two channels linked together providing
a certain differential level between them, as well as it can
be made independently for each of the two channels. Also»
these, models of voltmeters are incorporated with a GND MODE
selector so that the circuit ground can be connected to or
floated from the case ground.
Models AVM23R and AVM25R Voltmeters are capable of remote
control of range selection.. The remote control signal used
for this purpose is a positive-logic TTL-level binary-coded
signal with 4 bits per channel. The Remote Controllers which
can be used for this purpose are RC01-AVM, RC02-AVM,
RCOl-ORC, and RC02-ORC, When the IF01-AVM (GP-IB interface)
is used, digital data corresponding to pointer deflection
can be sent to the CPU making use of the range selection
control signal and DC output signal of the voltmeter.
All of the six models of Voltmeters are provided with an AC
output terminal which delivers an output signal of
approximately CL.1 V rms for full scale. Models AVM23R and
AVM25R Voltmeters are provided with a DC output terminal
which delivers an output signal of 1 V (±3%) for full scale..
Manual Type:
Service and User Manual
Pages:
35
Size:
2.16 Mbytes (2264145 Bytes)
Language:
english
Revision:
Manual-ID:
Z1-111-120, IA001812
Date:
2001 01 01
Quality:
Scanned document, all readable.
Upload date:
2017 09 02
MD5:
4ccbae14531d765a090754072083344f
Downloads:
2391
Information
1. GENERAL . , ... 1
2. SPECIFICATIONS ... , ... 3
2.1 Specifications Common to All. Models
., ... 3
2.2 Power Consumptions and Weights- ... 4
2.3 Measuring Voltage Ranges 4
2.4 Maximum Allowable Input Overvoltages- ... 4
2.5 Isolation of Circuit Ground from Case Ground 5
2.6 DC Output
... 5
2.7 Remote Control of Range Selection ... 5
3. NOTES BEFORE USE ... 7
3.1 Unpacking and Inspection .
... 7
3.2 AC Line Voltage
... 7
3.3 Operating Environments ... 8
3.4 Mechanical Zero Adjustment of Indicating Meter
... 8
3.5 GND MODE Switch. [Dual-pointer Models]
... 8
3.6 Circuit Ground and Case Ground
... 9
3.7 Remote Control Connector [AV23R, 25R] ... 9
3.8 Others ... 10
4. OPERATION METHOD
... 14
4.1 Description of Front Panel Items
... , ... 14
4 .2 Description of Rear Panel Items ... . 16
4.3 Measuring Procedure ... 18
4.4 Frequency Range for Guaranteed Accuracy ... 18
4.5 Signal Waveforms and Indication Errors ... 19
4.6 Remote Control of Range Selection [AV23R, 25R] 20
5. MAINTENANCE ... 26
5.1 Meter Cover ... 26
5.2 Adjustment and Calibration 26
5.3 Others.
... 31