Equipment information

Thurlby Thandar Instruments TTI TSX Series Power supply
Manufacturer:
Model:
TSX Series
Date:
2009
Category:
Group:
Description:
Programmable High Current DC Power Supplies

Information

OUTPUT SPECIFICATIONS Output Voltage Range: 0V to 35.3V (35V/10A); 0V to 18.15V (18V/20A). Output Current Range: 0.01A to 10.2A (35V/10A); 0.01A to 20.2A (18V/20A). Output Voltage Setting: Direct keyboard entry or quasi-analogue rotary control; setting resolution 10mV. Output Current Setting: Direct keyboard entry or quasi-analogue rotary control; setting resolution 10mA. Output Mode: Constant voltage or constant current with automatic crossover. Output Switch: Electronic. Preset voltage and current displayed when off. Output Terminals: 4mm terminals on front panel, screw terminals at rear. Sensing: Remote via rear panel screw terminals or direct via shorting strip (supplied). Output Impedance: <1mΩ in constant voltage mode. >5kΩ in constant current mode (voltage limit at max.). Output Protection: Forward protection by Over-Voltage-Protection (OVP) trip; maximum voltage that should be applied to the terminals is 50V. Reverse protection by diode clamp for reverse currents up to 3A. OVP Setting: Direct keyboard entry. OVP Range: 1V to 40V (35V/10A); 1V to 25V (18V/20A). OVP Delay: <200μs Load & Line Regulation: <0.01% of maximum output for 90% load change or 10% line change. Ripple & Noise: <1mV rms typical in constant voltage. <3mA rms typical in constant current. HF Common Mode Noise: Typically <3mV rms, <10mV peak. Transient Response: 20μs to within 50mV of setting for 90% load change. Temperature Coefficient: typically <100 ppm/°C. Protection Functions: Overvoltage trip; regulator overtemperature; sense miswiring. Status Indication: Output off lamp; constant voltage mode lamp; constant current mode lamp; trip message on display. METER SPECIFICATIONS Meter Types: Dual 4 digit meters with 12·5mm (0.5") LEDs. Reading rate 4Hz. Meter Resolution: 10mV, 10mA Meter Accuracy: Voltage 0.2% of reading ± 1 digit, current 0.5% of reading ± 1 digit. KEYBOARD FUNCTIONS Delta Mode: Increase or decrease voltage or current in user-selectable steps. Store/Recall: Store and recall voltage, current and OVP levels from non-volatile memory (25 memories). Interface Selection: Set digital Interface type (RS232 or GPIB), baud rate and address.

show more

User Manual
Manual Type:
User Manual
Pages:
95
Size:
1.96 Mbytes (2052198 Bytes)
Language:
english, german, french
Revision:
Issue 12
Manual-ID:
48511-0130
Date:
2009 01 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 01 14
MD5:
11956a66d324f0e3355b44f4cb497be5
Downloads:
865

Information

Specification 3 Safety 5 EMC 6 Installation 7 Manual Operation 8 Maintenance and Repair 11 Remote Operation 12 ARC Interface 13 Remote Commands 22 Instructions en Francais Sécurité 34 Montage 35 Fonctionnement manuel 36 Entretien et Réparations 40 Fonctionnement à distance 41 Commandes à distance 52 Bedienungsanleitung auf Deutsch Sicherheit 64 Installation 65 Handbedienung 66 Wartung und Instandsetzung 70 Fernbetrieb 71 Fernbefehle 82 1

show more

User Manual
Manual Type:
User Manual
Pages:
95
Size:
867.72 Kbytes (888548 Bytes)
Language:
english, german, french
Revision:
Issue 13
Manual-ID:
48511-0130
Date:
2013 01 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 01 14
MD5:
1b73ba08af63e918fc8289d61fdc62e3
Downloads:
398

Information

Specification 2 Safety 4 EMC 6 Installation 7 Manual Operation 8 Maintenance and Repair 11 Remote Operation 12 ARC Interface 13 Remote Commands 22 Instructions en Francais Sécurité 34 Montage 35 Fonctionnement manuel 36 Entretien et Réparations 40 Fonctionnement à distance 41 Commandes à distance 52 Bedienungsanleitung auf Deutsch Sicherheit 64 Installation 65 Handbedienung 66 Wartung und Instandsetzung 70 Fernbetrieb 71 Fernbefehle 82