Informações sobre o equipamento:

Philips PM2519 Multímetro digital
Fabricante:
Philips
Modelo: PM2519
Data: 1985
Categoria: Instrumentos de medição
Grupo: Multímetro digital
Descrição: Automatic Multimeter
Informações:
                                    The PM2519 automatic multimeter is a digital multifunction
measuring instrument with an internal microprocessor that
results in a simple but extremely powerful measuring tool.
The standard measuring functions of voltage, current and
resistance are provided with auto-ranging and true r.m.s.
a.c. measurements.
Additional measuring functions include:
- dB measurements with choice of 0 dB reference
- frequency measurements
- temperature measurements with a Pt 100 probe
- relative reference measurements against a selected or set zero
- continuity checks, and the measurement of the
forward/backward resistance of diodes.
Output values are indicated on a 41Λ - digit liquid-crystal
display (LCD) with decimal points and a wide variety of
function indications.
A built-in bargraph gives an analog indication of outputs,
enabling trends and orders of magnitude to be seen at a glance.
An audible signal is available for continuity and level
checks against a set relative reference value.
The PM2519 is normally operated from an a.c. mains supply,
but a /21-version is available for field operation that can
be powered from internal batteries for a approx. 30 hours,
these batteries are rechargeable in situ via the
instrument's mains supply.
A wide range of optional accessories are available,
including temperature, EHT, HF and data hold probes, shunts
and current transformers.
2.1. VERSIONS
PM2519/01 The PM2919/01 is the basic version of the
automatic multimeter. From this typenumber the following
versions are derived.
PM2519/21 A PM2519/01 with a built-in battery option. The
rechargable batteries of the PM2519/21 can be charged via
the instrument's mains supply.
PM2519/51 The PM2519/51 version has a system adaptor and an
IEC-625/IEEE-488 bus interface for digital output data and
remote control (except for the main function switch).

Esses manuais estão disponíveis para o equipamento acima:

Philips -- PM2519 -- Manual de serviço
O nome do arquivo: Philips-517-Manual-Page-1-Picture
Tipo manual: Manual de serviço
Páginas: 126
Tamanho: 4.15 Mbytes (4350797 Bytes)
Idioma: Inglês
Revisão:
Manual-ID/Number: 9499 475 02111
Data: 09 March 1987
Qualidade: Scaned documento, todas legível.
Envie data:
MD5: f2d3aacd500b43e8311a5fb2977b83a2
ed2kID: 892d9b8128b3ea4a5df57dd0813d1364
Downloads: 2373 desde 07 March 2008
Informações:
Important:
This manual is based on instruments with a serial number DY 01 3611 and onwards.
In chapter 9, modifications to the PM2519, an overview is given of modifications in the earlier instruments.
Includes the Service Informations SME116 and SME 117 (9499 478 14711 and 9499 478 14811)
Philips-517-Manual-Page-1-Picture
Iniciar Download


Philips -- PM2519 -- Manual do Usuário
O nome do arquivo: Philips-6743-Manual-Page-1-Picture
Tipo manual: Manual do Usuário
Páginas: 18
Tamanho: 8.23 Mbytes (8634321 Bytes)
Idioma: Inglês
Revisão:
Manual-ID/Number: 4822 872 30021
Data: 25 March 1985
Qualidade: Scaned documento, todas legível.
Envie data:
MD5: 2497e701054832c781ed713dc2352450
ed2kID: 582c7d8b04bdcf528c618df59ea35208
Downloads: 285 desde 19 May 2015
Informações:
1. SAFETY 1
2. GENERAL INFORMATION 2
2.1. Versions..........................................2
2.2. Features..........................................2
2.2.1. Relative reference measurements
................................2
2.2.2. Bargraph display..............................2
2.2.3. dB measurements............................3
2.2.4. Audible signals and
indicators........................................3
3. CHARACTERISTICS 4
3.1. Performance characteristics. ... 4
3.2. Safety characteristics.......................5
3.3. Initial characteristics.......................5
3.4. Environmental characteristics . . 5
3.5. Climatic conditions.........................5
3.6. Mechanical requirements................6
3.7. Mains supply conditions..................6
3.8. Battery supply conditions
(/21 version only)...........................6
3.9. Electromagenetic interference . . 6
3.10. Accessories.....................................6
4. INSTALLATION INSTRUCTIONS 7
4.1. Initial inspection ............................7
4.2. Safety instructions.........................7
4.2.1. Earthing..........................................7
4.2.2. Mains voltage setting and
fuses ...............................................7
4.3. Location and replacement
of fuses............................................7
4.4. Operating position of the instrument
.....................................7
5. OPERATING INSTRUCTIONS 8
5.1. General information................. 8
5.2. Switching on............................. 8
5.3. Display...................................... 8
5.4. Control features........................ 8
5.4.1. Relative reference
(ZERO SET)............................. 8
5.4.2. Preset......................................... 10
5.4.3. Ranging .................................... 11
5.5. Control functions...................... 11
5.5.1. V— measurements................... 11
5.5.2. mV rr. measurements .............. 11
5.5.3. V- K > PRESET measurements .......................... 11
5.5.4. V ~ rms measurements............ 12
5.5.5. A — measurements................... 12
5.5.6. A ~ rms measurements............ 12
5.5.7. Ω measurements...................... 12
5.5.8. -Wr Κ<10Ω
measurements .......................... 13
5.5.9. °C measurements...................... 13
5.5.10. Hz measurements...................... 13
5.5.11. dB measurements...................... 13
APPENDIX 1. OPTIONAL ACCESSORIES 15
A1.1. HT Probe PM9246 ................... 15
A1.2. Shunt PM9244 and current
transformer PM9245 ................. 15
A1.3. HF probe PM9210 and
accessory set PM9212.............. 16
A1.4. DATA HOLD probe PM9267 .. 17
A1.5. Current gun............................... 17
Philips-6743-Manual-Page-1-Picture
Iniciar Download


Comentários

Sem comentários.

Adicionar Comentário

* Informação requerida
(não será publicado)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Type the word for the number 9.
 
Digite a resposta:
 
Notifique-me de novos comentários via email.
 
Lembrar minhas informações neste computador.
 
 
Powered by Commentics