Sanyo KMS0912 Air Conditioner
Manufacturer:
Image 1 of 1
If you have any other photos or manuals for the
Sanyo KMS0912 you can upload the files here .
Model:
KMS0912
Date:
Category:
Group:
Description:
Split System Air Conditioner
Manual Type:
Part List
Pages:
8
Size:
538.01 Kbytes (550918 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
2013 12 14
MD5:
3430b4d2e017cdd88b7b4fd0f68631e7
Downloads:
1766
Manual Type:
Service Manual
Pages:
33
Size:
2.55 Mbytes (2675009 Bytes)
Language:
english
Revision:
Manual-ID:
W M -7 0 0 8 2 7
Date:
Quality:
Scanned document, all readable.
Upload date:
2016 12 21
MD5:
a56fa4ba741dec723e64713a03ce7df4
Downloads:
973
Information
1.SPE C IFIC A T IO N S
1-1 Unit S p ecification
s ...
(1) CM 1 8 1 2
...
: ...
(2) Applicable Indoor U n
it ...
1-2 Major Component S p ecification
s ...
(1) Outdoor U
nit ...
(2) Indoor U n
it ...
1-3 Other Component
Specifications ...
(1) Outdoor U
nit ...
(2) Indoor U n
it ...
2.3.P E R F O R M A N C E C H A R T S
2-1 Operating
Current ...
2-2 High and Low
Pressure ...
AIR T H R O W D IST A N C E C H A R T
...
4. FU N C T IO N
4-1 Room Temperature C
ontrol ...
4-2 Freeze
Prevention ...
4-3 Fan Speed Auto (Indoor F an
) ...
5. E L E C T R IC A L DATA
• Schcm atic D iag ram
...
• Electric Wiring Diagram (PCB A ss’y )
...
6. T R O U B L E SH O O T IN G
6-1 Check before and after
troubleshooting ...
(1) Check power supply w
iring ...
(2) Check inter-unit w
iring ...
(3) Check power su p p ly
...
(4) Check lead wires and connectors in indoor and outdoor
units ...
(5) R
eference ...
(a) Condition of general cooling operation
6-2 Air Conditioner does not
operate ... 16
(1) Circuit breaker trips (or fuse b lo w
s) ...
16
(a) When circuit breaker is set to ON, it trips in a few moments
(b) Circuit breaker trips in several minutes after turning
Air Conditioner ON
(2) All units (indoor and outdoor) do not
run ...
... 18
(a) Power is not supplied
(b) Check OPERATION selector switch in indoor unit
(c) Check fuse FI in indoor unit
(3) Neither indoor unit A nor compressor motor A
runs ...
... 20
(a) Check transformer in indoor unit A (or B)
(b) Check fuse on PCB A ss’y in indoor unit A (or B)
6-3 A particular component o f Air Conditioner does not
operate ...
... 22
(1) Only compressor motor A does not run (or B )
...
... 22
(2) Only indoor fan does not
run ...
... 23
(3) Only outdoor fan does not r u n
...
.· ... 23
6-4 Air Conditioner operates, but abnormalities
occur ...
24
(1) Poor C
ooling ...
24
(2) E xcessive C o o lin g
...
... 25
6-5 Indoor (heat exchanger) coil temperature sensor (TH1) is
d efectiv
e ...
... 25
(1)
Open ...
... 25
(2)
Shortage ...
... 25
7.C H E C K IN G E L E C T R IC A L C O M P O N E N T S
7-1 Measurement o f Insulation R
esistance ...
... 26
(1) Power Supply W
ires ...
26
(2) Indoor U n
it ...
... 26
(3) Outdoor U
nit ...
... 26
(4) Measurement o f Insulation Resistance for Electrical
Parts ...
... 26
7-2 Checking Continuity o f Fuse on PCB A ss’y
...
... 27
7-3 Checking Motor
Capacitor ...
... 27
7-4 Appearance o f Electrical P
arts ...
... 28
(1) Auxiliary R
elay ...
... 28
(2) R ela y
...
... 28
Manual Type:
Service Manual
Pages:
15
Size:
792.00 Kbytes (811004 Bytes)
Language:
english
Revision:
Manual-ID:
8526481022500
Date:
Quality:
Scanned document, all readable.
Upload date:
2013 12 10
MD5:
ea24ef1f7c81a164c2a182cf3fdc6877
Downloads:
1402