Description:
Selective Level Meter
Information
The 3586A/B Selective Level Meter is designed for use in the design, manufacture, installation, and maintenance of Frequency Division Multiplex (FDM) systems and for general purpose wave analysis and frequency synthesis. The 3586A is available to meet the needs of C.C.I.T.T. requirements, while the 3586B meets North American (Bell) Standards. The 3586C is a general purpose instrument.
The 3586A/B provides the ability to make both carrier frequency measurements to 32.5MHz and voice channel measurements from 50Hz to 100kHz.
The Transmission impairments Option 003 allows the user to quickly troubleshoot voice channel problems with phase jitter, noise-with-tone, signal-to-noise-with-tone-ratio, and single level impulse noise measurements, all with one instrument. The capability to make all these transmission impairment measurements combined with both FDM voice channel and carrier frequency measurements is available only on the 3586A/B. Standard models include a 1740Hz psophometric or 2000Hz C-message equivalent noise filter, or weighted noise measurements can be made directly with the 3100Hz channel Filter and noise weighting Filter provided with the Transmission Impairments Option 003. Filter shape factor of < 1.2 provides 60dB carrier and 75dB adjacent channel rejection.
Manual Type:
Service Manual
Pages:
258
Size:
24.89 Mbytes (26096342 Bytes)
Language:
english
Revision:
Manual-ID:
03586-90002V1
Date:
Quality:
Scanned document, all readable.
Upload date:
2013 11 23
MD5:
0cd427becc8abaa881d815836a7e46d2
Downloads:
2185
Information
This manual applies to all instruments. Earlier versions of
the 3586A/B/C, however, may differ in design and appearance
from the instruments this revision documents directly.
Changes that have been made to the instrument and which
affect the instrument's documentation are identified by the
Delta (A) symbol. The "numbered" A refers the reader to the
corresponding numbered A in the backdating section (Section
VII) in Volume I of the 3586A/B/C Service Manual.
Service Manual Volume I
Manual Type:
Service Manual
Pages:
185
Size:
44.42 Mbytes (46579470 Bytes)
Language:
english
Revision:
Manual-ID:
03586-90002V2
Date:
Quality:
Scanned document, all readable.
Upload date:
2013 11 23
MD5:
137553d35232883d5e2da88fdfcbcf50
Downloads:
2346
Information
Service Manual Volume II
This manual applies to all instruments. Earlier versions of
the 3586A/B/C, however, may differ in design and appearance
from the instruments this revision documents directly.
Changes that have been made to the instrument and which
affect the instrument's documentation are identified by the
Delta (A) symbol. The "numbered" A refers the reader to the
corresponding numbered A in the backdating section (Section
VII) in Volume I of the 3586A/B/C Service Manual.
8-2. This volume of the Service Manual contains information
relative to the maintenance and service of the 3586A/B/C
Selective Level Meter. The information presented in this
manual is assembled into four major segments: Turn-on
Initialization and Milking the Front Panel, Troubleshooting,
Detailed Functional (circuit) Description, and Service
Groups. Where references are made throughout the manual to a
performance test, adjustment procedure, the parts list, or
backdating section, refer to Volume I: 3586 Performance
Tests, Adjustments, Parts, and Backdating. In order to
obtain a minimum of instrument down time and to provide for
the greatest amount of troubleshooting efficiency and
safety, it is recommended that Safety Considerations
(paragraph 8-5), Use Of The Service Manual (paragraph 8-8),
and Service Volume Organization (paragraph 8-11) be read
before initiating any troubleshooting procedures.
Manual Type:
User Manual
Pages:
146
Size:
4.26 Mbytes (4470828 Bytes)
Language:
english
Revision:
Manual-ID:
03586-90012
Date:
Quality:
Scanned document, all readable.
Upload date:
2013 11 23
MD5:
49036966b1a619c78917cd8eee76af85
Downloads:
1619
Information
This manual applies to instruments with serial number
prefixed 1927A, 192«A, and 1929A.