Informacje o sprzęcie

Tektronix 2230 Oscyloskop
Producent:
Tektronix
Modelu: 2230
Data: 1985
Kategorii: Przyrządy pomiarowe
Grupa: Oscyloskop
Opis: Digital Storage Oscilloscope
Informacje:
                                    INTRODUCTION!

The TEKTRONIX 2230 Oscilloscope! is a combination nonstorage
and digital storage dual-channel 100 MHz bandwidth instrument.
It is a rugged, lightweight oscilloscope featuring
microprocessor operation and alphanumeric crt readout
of many of the front-panel controls. In the digital
storage mode, up to three waveform sets (CH 1 and/or CH 2)
may be stored in a SAVE REF memory and recalled for
display at a later time. The vertical system provides
calibrated deflection factors from 2 mV per division
to 5 V per division. The horizontal system provides
calibrated sweep speeds from 50 ns per division to 0.5 s
per division for nonstorage mode with three slower
sweep speeds (1 s, 2 s, and 5 s per division) added
for store mode operation. A X10 magnifier extends
the maximum sweep speed to 5 ns per division.

The digital storage sampling rate is 20 megasamples
per second maximum, and the acquired record length is
4K samples (1K may also be selected) for a single
channel or 2K samples for dual-channel (CHOP or ALT)
displays. Any contiguous 1K sample of an acquired record
is displayable. The fast sampling rate can capture a
glitch with a pulse width of at least 100 ns. A 4K
compress feature enables a 4K record length acquisition
to be compressed to 1K in length for ease in viewing or
storing in the SAVE REF memory. If compression is not
desired, all 4K or any 1K portion of a 4K record may be
stored in the SAVE REF memory. The SAVE store mode stops
the waveform acquisition in progress, allowing a particular
display to be stored or examined before further acquisitions
cause a waveform update.
Cursors may be used to obtain voltage measurements,
time difference measurements, and delay-time measurements
on any of the store mode waveform displays. Delta
volts, delay time, delta time, and 1/delta time (either
delta time or 1/delta time is selectable via the MENU)
are displayed in the crt readout for ease in obtaining
precise measurement results. The cursors are positioned
to any displayed store mode waveform to make measurements.
An alternate use of the cursor-positioning control is
to horizontally position the 1K display window to
any location within a 4K record length waveform
acquisition. The displayed portion of a 4K acquisition
is stored when the SAVE REF feature is used.

Te Podręczniki są dostępne dla powyższego urządzenia:

Tektronix -- 2230 -- Instrukcja obsługi
Nazwa pliku: Tektronix-2519-Manual-Page-1-Picture
Typ instrukcji: Instrukcja obsługi
Stron: 188
Rozmiar: 12.25 Mbytes (12845836 Bytes)
Język: Angielski
Zmiana: Revised
Podręcznik numer: 070-4998-02
Data: maj 1988
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: 0f25629be9d385fe183dbac5d60acc5b
Pliki do pobrania: 1366 od 13 czerwiec 2011
Informacje:
Tektronix-2519-Manual-Page-1-Picture
Start do pobrania za darmo


Tektronix -- 2230 -- Serwis i User Manual
Nazwa pliku: Tektronix-4506-Manual-Page-1-Picture
Typ instrukcji: Serwis i User Manual
Stron: 472
Rozmiar: 53.53 Mbytes (56125048 Bytes)
Język: Angielski
Zmiana: Revised
Podręcznik numer: 070-4999-00
Data: maj 1987
Jakość: Skanowany dokument, czytając częściowo źle, nie częściowo czytelny.
Data wysłania:
MD5: 7c8d70835a74c043395ecc5d8fe9babb
Pliki do pobrania: 3214 od 25 kwiecień 2013
Informacje:
Tektronix-4506-Manual-Page-1-Picture
Start do pobrania za darmo


Comments (1)

 
 
Topic: Tektronix 2230
0/5 (0)
 
Gravatar
New
Thomas Keel
Gravatar
1
0
0
Apr 2017
First Poster
Thomas Keel says...
thanks so much.

Add Comment

* Required information
1000
Enter the word hand backwards.
Powered by Commentics