Equipment information

Fluke 8000A Digital multimeter
Manufacturer:
Model:
8000A
Date:
1973
Category:
Group:
Description:

Information

1-2. The Model 8000A is a compact and light-weight digital multimeter (DMM). It features a 3Vz digit display, push-button selection of range and function, auto polarity, self locating decimal point, self zeroing to eliminate offset uncertainties, and overload protection for all ranges. Several options and Accessories are also available for use with the 8000A. 1 -3. Push-button controls allow the selection of five ac and dc voltage ranges, five ac and dc current ranges, and six resistance ranges. The measurement capabilities of the 8000A range from 100 microvolts to 1199 volts ac and dc, 100 nanoamperes to 1.999 amperes ac and dc, and 100 milliohms to 19.99 megohms. 14. The front-panel readout features a 3lA digit display using light emitting diodes (LED’s). The display includes a self locating decimal point and a + or - polarity indicator. Full-scale readout is 1999 for all ranges and functions except the 1200 volt ac and dc range, which is 1199. A blinking full-scale readout indicates that the 8000A is being operated in an overrange condition. 1-5. Front panel input connectors are banana type and provide separate connections for common, current, and volt-ohm inputs. Both the current and volt-ohm inputs are referenced to the common input. Common is isolated from earth ground and can operate at a potential of up to ± 1.200 volts peak with reference to earth ground. 1-6. The overload features of the 8000A include a fused current input and an overvoltage protected volt-ohm input. This protection applies for any function and range selected. 1-7, Several options and Accessories are available for use with the 8000A. The options are listed and described in Table 1-1, and option compatibility is defined in Table 1-2. Desired options must be specified at time of purchase. The Accessories are listed and described in Table 1-3. Accessories are compatible with all options and can be ordered at time of purchase or after purchase. Detailed information concerning each option and accessory is given in Section 6 of this manual. 1-8. Input power for the 8000A is available in one-of- three versions. These are: 100 volts, 50 to 400 Hz; 115 volts, 50 to 400 Hz; and 230 volts, 50 to 400 Hz. The desired version must be specified at the time of purchase. Overall operation of the 8000A is the same for all versions of input power.

show more

Service and User Manual
Manual Type:
Service and User Manual
Pages:
82
Size:
3.86 Mbytes (4049263 Bytes)
Language:
english
Revision:
Manual-ID:
347906
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
2016 02 13
MD5:
c24588cfc55c4a1e6bd0f47c316f848e
Downloads:
1674

Information

1 INTRODUCTION AND SPECIFICATIONS ... 1-1 1-1. INTRODUCTION . ... 1-1 1-9. SPECIFICATIONS ... 1-2 2 OPERATING INSTRUCTIONS ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SHIPPING INFORMATION ... 2-1 2-6. INPUT POWER ... 2-1 2-9. RACK INSTALLATION ... 2-1 2-11. OPERATING FEATURES ... 2-1 2-13. OPERATING NOTES ... 2-1 2-15.. Option Information ... 2-1 2-17. Fuses. ... 2-3 2-19. Overrange Indication ... 2-3 2-21. Input Overload Protection ... 2-3 2-23. OPERATION ... 2-3 3 THEORY OF OPERATION ... 3-1 3-1. INTRODUCTION ... 3-1 3-3. SIMPLIFIED BLOCK DIAGRAM ANALYSIS ... 3-1 3-4. Introduction ... 3-1 3-6. Input Signal Conditioner ... 3-1 3-8. A/D Converter ... 3-1 3*10. Display ... 3-1 3-11. CIRCUIT DESCRIPTION ... 3-2 3-13. Signal Conditioning ... 3-2 3-27. Analog-to-Digital Converter ... 3-3 3-38. Display ... 34 3-50. Power Supply ... 3-5 4 MAINTENANCE ... 4-1 44. INTRODUCTION ... 4-1 4-5. GENERAL MAINTENANCE ... 4-2 4-6. Access Information ... 4-2 4-8. Cleaning ... 4-2 4-10. Fuse Replacement ... 4-2 443. Service Tools ... 4-2 4-15. PERFORMANCE TEST ... 4-2 4-17. Zero Offset Test ... 4-2 449. Accuracy Test ... 4-2 4-21. CALIBRATION ... 4-3 4-23. Initial Procedure ... 4-3 4-25. Period Adjustment ... 4-3 4-27. Zero Offset Adjustment ... 4-3 4-29. Turn-Over Error Adjustment ... 4-3 4-31. Range Adjustments/Checks ... 4-4 4-33. TROUBLESHOOTING ... 44 5 LIST OF REPLACEABLE PARTS ... 5-1 5-1. INTRODUCTION ... 5-2 54. HOW TO OBTAIN PARTS ... 5-2 5-7. USE CODE EFFECTIVITY LIST ... 5-2 6 OPTIONS AND ACCESSORIES ... 6-1 6-1. INTRODUCTION ... 6-1 6-3. CARRYING CASE (C80) ... 6-1 6-5. CARRYING CASE (C86) ... 6-1 6-7. FRONT PANEL DUST COVER . ... . . 6-1 6-9. RACK MOUNTING KITS ... 6-1 6-10. introduction ... 6-1 6-12. Installation Procedure ... 6-2 6-16. DELUXE TEST LEAD KIT ... 6-2 6-18. CURRENT PROBE, CLAMP-ON ... 64 6-19. Introduction . ... 6-4 6-21. Operation ... 64 6-23. HIGH VOLTAGE PROBE ... 6-5 6-24. Introduction ... 6-5 6-26. Specifications ... 6-5 6-27. Operation ... 6-5 6-29. HIGH FREQUENCY Probe (80RF-1) ... 6-6 6-30. Introduction ... 6-6 6-32. Specifications ... 6-6 6-33. Operating Notes ... 6-6 6-36. Operation ... 6-6 6-38. Theory of Operation ... 6-7 6-41. 6 OPTIONS AND ACCESSORIES, continued 6-50. HIGH FREQUENCY Probe (81RF) ... 6-9 6-51. Introduction ... 6-9 6*53. Specifications ... 6-9 6-54. Operation ... 6*9 6-56. BATTERY PACK, OPTION —01 ... 6-9 6-57. Introduction ... 6-9 6-59. Specifications ... 6-9 6*61. Operation ... 6-9 6-63. Theory of Operation ... 6-9 6-66. Maintenance ... 6-10 6-71. DIGITAL PRINTER OUTPUT UNIT, OPTION —02 ... 6-10 6-72. Introduction ... 6-10 6-74. Specifications ... 6-10 6-76. Operation ... 6-10 6-87. Theory of Operation ... 6-13 6-91. 10A CURRENT RANGE, OPTION —05 ... 6-13 6-92. Introduction ... 6-13 6-94. Specifications ... ... 6-13 6-96. Operation ... 6-13 6-98. Theory of Operation ... 6-13 6*100. LOW OHMS OPTION (-06) ... 6-15 6-101. Introduction ... 6-15 6-103, Specifications ... 6-15 6-105. Operation ... 6-15 7 GENERAL INFORMATION ... 7-1 8 SCHEMATIC DIAGRAMS ... 8-1Maintenance ... 6-7

show more

User Manual with schematics
Manual Type:
User Manual with schematics
Pages:
76
Size:
4.03 Mbytes (4227377 Bytes)
Language:
english
Revision:
3 8/73
Manual-ID:
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
2009 02 19
MD5:
c60837a754b51580c850409e4a91dad6
Downloads:
4590