Informacje o sprzęcie

Fluke 177 Multimetr cyfrowy
Producent:
Fluke
Modelu: 177
Data: 2000
Kategorii: Przyrządy pomiarowe
Grupa: Multimetr cyfrowy
Opis: True RMS Multimeter
Informacje:
                                    The Fluke Model 175, Model 177, and Model 179 are
batterypowered,
true-RMS multimeters (hereafter "the Meter") with a
6000-count, 3 3/4-digit display and a bar graph. This manual
applies to all three models. All figures show the Model 179.
These meters meet CAT III and CAT IV IEC 61010 standards.
The IEC 61010 safety standard defines four overvoltage
categories (CAT I to IV) based on the magnitude of danger from
transient impulses. CAT III meters are designed to protect
against
transients in fixed-equipment installations at the
distribution level;
CAT IV meters are designed to protect against transients
from the
primary supply level (overhead or underground utility service).
The Meter measures or tests the following:
¨ AC / DC voltage & current ¨ Diodes
¨ Resistance ¨ Continuity
¨ Voltage & frequency ¨ Capacitance
¨ Temperature (Model 179 only)

Te Podręczniki są dostępne dla powyższego urządzenia:

Fluke -- 177 -- Instrukcja obsługi
Nazwa pliku: Fluke-1028-Manual-Page-1-Picture
Typ instrukcji: Instrukcja obsługi
Stron: 18
Rozmiar: 514.51 Kbytes (526862 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer:
Data: maj 2003
Jakość: Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data wysłania:
MD5: 185881f886ce762e9c3998e9f62b593c
Pliki do pobrania: 2056 od 21 listopad 2008
Informacje:
Title Page
Contacting Fluke ................................................................................................................... 1
"Warning" and "Caution" Statements..................................................................................... 1
Unsafe Voltage...................................................................................................................... 1
Test Lead Alert ...................................................................................................................... 1
Battery Saver ("Sleep Mode")................................................................................................ 2
Terminals .............................................................................................................................. 2
Rotary Switch Positions......................................................................................................... 2
Display ................................................................................................................................. 3
MIN MAX AVG Recording Mode ........................................................................................... 4
Display HOLD and AutoHOLD Modes................................................................................... 4
YELLOW Button.................................................................................................................... 4
Display Backlight (Model 177 and 179 Only) ......................................................................... 4
Manual Ranging and Autoranging ......................................................................................... 5
Power-Up Options ................................................................................................................. 5
Making Basic Measurements................................................................................................. 6
Measuring AC and DC Voltage......................................................................................... 6
Measuring Resistance...................................................................................................... 6
Measuring Capacitance.................................................................................................... 6
Testing for Continuity........................................................................................................ 7
Measuring Temperature (Model 179 Only) ....................................................................... 7
Testing Diodes ................................................................................................................. 7
Measuring AC or DC Current ........................................................................................... 8
Understanding AC Zero Input Behavior of True RMS Meters ........................................... 8
Measuring Frequency....................................................................................................... 9
Using the Bar Graph.............................................................................................................. 9
Cleaning............................................................................................................................... 10
Testing the Fuses.................................................................................................................. 10
Replacing the Battery and Fuses........................................................................................... 10
Specifications ........................................................................................................................ 11
Fluke-1028-Manual-Page-1-Picture
Start do pobrania za darmo


Fluke -- 177 -- Instrukcja obsługi
Nazwa pliku: Fluke-7602-Manual-Page-1-Picture
Typ instrukcji: Instrukcja obsługi
Stron: 18
Rozmiar: 510.32 Kbytes (522571 Bytes)
Język: Angielski
Zmiana: 2
Podręcznik numer:
Data: maj 2002
Jakość: Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data wysłania:
MD5: bb1bf62924ac012de36076552feaeaaf
Pliki do pobrania: 118 od 26 styczeń 2016
Informacje:
Warning. Read before using the
Meter:.................................................................................
ii
Contacting Fluke
...................................................................................................................
1
"Warning" and "Caution" Statements
....................................................................................
1
Unsafe Voltage
.....................................................................................................................
1
Test Lead
Alert......................................................................................................................
1
Battery Saver ("Sleep Mode")
...............................................................................................
2
Terminals
..............................................................................................................................
2
Rotary Switch Positions
........................................................................................................
2
Display
.................................................................................................................................
3
MIN MAX AVG Recording Mode
...........................................................................................
4
Display HOLD and AutoHOLD
Modes...................................................................................
4
YELLOW
Button....................................................................................................................
4
Display Backlight (Model 177 and 179
Only).........................................................................
4
Manual Ranging and
Autoranging.........................................................................................
5
Power-Up
Options.................................................................................................................
5
Making Basic Measurements
................................................................................................
6
Measuring AC and DC Voltage
........................................................................................
6
Measuring
Resistance......................................................................................................
6
Measuring Capacitance
...................................................................................................
6
Testing for Continuity
.......................................................................................................
7
Measuring Temperature (Model 179
Only).......................................................................
7
Testing Diodes
.................................................................................................................
7
Measuring AC or DC Current
...........................................................................................
8
Understanding AC Zero Input Behavior of True RMS
Meters........................................... 8
Measuring Frequency
......................................................................................................
9
Using the Bar Graph
.............................................................................................................
9
Cleaning...............................................................................................................................
10
Testing the
Fuses..................................................................................................................
10
Replacing the Battery and Fuses
..........................................................................................
10
Specifications.......................................................................................................................
11
Fluke-7602-Manual-Page-1-Picture
Start do pobrania za darmo


Comments

No comments yet.

Add Comment

* Required information
(never displayed)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Out of 56, 14 or 27, which is the smallest?
 
Enter answer:
 
Notify me of new comments via email.
 
Remember my form inputs on this computer.
 
 
Powered by Commentics