Informacje:
                                    When measuring vibration by means of an accelerometer, it is
necessary to incorporate a preamplifier between it and the
measuring amplifier. The preamplifier is introduced in the
measuring circuit for two reasons:

1.	to transform the high output impedance of the
accelerometer to a lower value and

2.	to amplify the relatively weak output signal from the
accelerometer.

The signal from the piezoelectric accelerometer appears as a
voltage across a capacitive impedance. As the capacitive
output impedance of the accelerometer is very high, the
associated amplifier must be of a special design having a
high input impedance. This is necessary in order to avoid
loading of the accelerometer and thereby obtaining decreased
sensitivity and limitation at the low end of the frequency
range.

The combination of a charge amplifier and a piezoelectric
accelerometer gives a sensitivity which is independent of
cable length within very wide limits. This feature makes a
charge amplifier especially attractive in vibration systems
where different cables are used. The Conditioning Amplifier
Type 2626 may be used with cable lengths up to several
thousand meters.

Another advantage the 2626 Amplifier offers is the wide
conditioning possibilities to different transducers and
measuring requirements. It features a 3 digit sensitivity
adjustment network which enables the amplifier sensitivity
to be adjusted to the particular transducer used. The
network is calibrated in pC/g. Output of the amplifier can
be adjusted stepwise between 1 mV/g and 10V/g, depending on
the transducer sensitivity. A maximum sensitivity of 1 V/pC
is available. The output signal is available either directly
coupled or through a transformer (switchable) for floating
output.

Stepwise adjustable HP and LP filters are incorporated, by
which the frequency limits can be adjusted independent of
sensitivity. The filter scales give the 5% as well as 3 dB
frequency limits. The lowest frequency limit for the
amplifier is 0.3 Hz which makes it quite suitable for
measurement of impulses.

Two neon indicators are connected to the output, one for
overload and the other for underload which lights when the
signal level is at least 1 V peak. On account of quick
recovery time after overload, the amplifier is also suitable
for use in a servo-loop in exciter systems.

Te Podręczniki są dostępne dla powyższego urządzenia:

Brüel & Kjær -- 2626 -- Instrukcja obsługi
Nazwa pliku: BruelKJAER-9057-Manual-Page-1-Picture
Typ instrukcji: Instrukcja obsługi
Stron: 17
Rozmiar: 848.72 Kbytes (869091 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer:
Data:
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: c39452e840bcdf7b718f8ac52c2c9896
Pliki do pobrania: 34 od 26 maj 2017
Informacje:
1.	INTRODUCTION..................................... 5

1.1.	General .................................... 5

1.2.	Charge Amplifier ............................ 6

1.3.	Principle of the Charge Amplifier ................ 7

2.	CONTROLS ......................................... 9

2.1.	Front Panel ................................. 9

2.2.	Rear Panel ................................. 12

3.	OPERATION ........................................13

3.1.	Input
..........................................................................13

3.2.	Output
.....................................................14

3.3.	Power Requirements...................................14

3.4.	Overload Reset
............................................................14

3.5.	Use in Servo-Loops of Exciter Control Systems .....14

3.6.	Low Frequency Measurements
....................................15

3.7.	Hum & Noise Reduction.................... ...	15

3.8.	Evaluation of Noise Referred to input
........................15
4.	DESCRIPTION .......................................19

4.1.	Input ..................................... 19

4.2.	Conditioning Section .........................20

4.3.	Filters .....................................20

4.4.	Output . ...................................20

4.5.	Signal Level Indicators ■........................21

4.6.	Power Supply ...............................21

4.7.	Output Characteristics ........................21

4.8.	Noise .....................................23

4.9.	Phase Characteristics..........................23
5.	USE WITH OTHER INSTRUMENTS
5.1.	Sensitivity Calibration of Accelerometers..........25

5.2.	Wide Band Random Test ......................27

5.3.	Mechanical Impedance Measurements.............28

5.4.	Correlation Measurements .....................28

6.	ACCESSORIES.......................................29
7.	SPECIFICATIONS
BruelKJAER-9057-Manual-Page-1-Picture
Start do pobrania za darmo


Brüel & Kjær -- 2626 -- Dane techniczne
Nazwa pliku: BruelKJAER-9067-Manual-Page-1-Picture
Typ instrukcji: Dane techniczne
Stron: 8
Rozmiar: 509.04 Kbytes (521260 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer:
Data:
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: 39d3d5026fca5b9409bc61362af8e1c9
Pliki do pobrania: 78 od 01 czerwiec 2017
Informacje:
BruelKJAER-9067-Manual-Page-1-Picture
Start do pobrania za darmo


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
What is the fifth month of the year?
Powered by Commentics