Informacje o sprzęcie

General Radio Company 716-C Inny
Producent:
General Radio Company
Modelu: 716-C
Data: 1959
Kategorii: Przyrządy pomiarowe
Grupa: Inny
Opis: Capacitance Bridge
Informacje:
                                    The Type 716-C Capacitance Bridge is a Schering bridge which
is direct reading in capacitance over the frequency range
from 30 c to 300 kc and in dissipation factor at four
specific frequencies, 100 c, 1 kc, 10 kc, 100 kc. The
resistance balance is made by means of a variable capacitor
connected across one of the ratio arms, as shown in Figure
1. Hence its reading in dissipation factor is proportional
to the ratio of the applied frequency to the frequency for
which the RANGE SELECTOR switch is set.
The bridge may also be used for all types of substitution
measurements by the addition of a fixed or variable
balancing capacitor. The direct-reading scales greatly
simplify the necessary calculations for capacitance and
dissipation factor.

Te Podręczniki są dostępne dla powyższego urządzenia:

Typ instrukcji: Serwis i User Manual GR-8240-Manual-Page-1-Picture
Stron: 28
Rozmiar: 17.50 Mbytes (18347201 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer: 681-K
Data: 01 listopad 1959
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: b339dc3fc3d79818ce9ee3e830f88a06
Pliki do pobrania: 53 od 30 grudzień 2016
Informacje:
Section 1.0
INTRODUCTION..........................................................
1
1.1
General..................................................................................
1
1.2 Range and
Accuracy..........................................................
1
Section 2.0
INSTALLATION..........................................................
2
2.1 Accessories
Supplied..........................................................
2
2.2 Accessories
Required..................................................... 2
2.3 Connections
............................................................................
2
Section 3.0 MEASUREMENTS.................................. 2
3.1 Direct Reading
Method..................................................... 2
3.2 Substitution
Method..........................................................
4
3.3 Substitution Methods with External Standards ... 6
Section 4.0 SPECIAL
MEASUREMENTS................................... 7
4.1 Measurement of High
Resistance...................................7
4.2 Measurement of Large
Inductance............................. 8
4.3 Partial Substitution Methods
.........................................8
4.4 Series Substitution
Methods............................................... 9
4.5 Series Resistance
Method...............................................10
4.6 Parallel Resistance
Method...............................................10
Section 5.0 OTHER
USES................................................................11
5.1 Voltage
Limits.....................................................................
11
5.2 Frequency
Range................................................................11
5.3 Measurement of
Dielectrics.........................................12
5.4 Measurement of Direct
Capacitance..............................13
5.5 Guard
Electrodes................................................................14
5.6 Polarizing Voltage .
...........................................................15
Section 6.0
CONSTRUCTION.....................................................15
6.1 Electrical
Circuit................................................................15
6.2
Adjustments............................................................................15
GR-8240-Manual-Page-1-Picture


Typ instrukcji: Serwis i User Manual GR-8256-Manual-Page-1-Picture
Stron: 22
Rozmiar: 9.95 Mbytes (10434607 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer: 681-K
Data: 01 listopad 1959
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: 11780845be95e98e2d3fd7641424bc0d
Pliki do pobrania: 59 od 30 grudzień 2016
Informacje:
Section 1.0
INTRODUCTION.........................................................
1
1.1
General................................................................................
1
1.2 Range and
Accuracy.........................................................
1
Section 2.0
INSTALLATION.........................................................
2
2.1 Accessories
Supplied.........................................................
2 ■ ' T
2.2 Accessories
Required................................................... 2
2.3
Connections..........................................................................
2 ^
" •
Section 3.0 MEASUREMENTS.................................. 2
3.1 Direct Reading
Method................................................... 2
3.2 Substitution
Msthod.........................................................
4
3.3 Substitution Methods with External Standards ... 6
Section 4.0 SPECIAL
MEASUREMENTS.................................. 7
4.1 Measurement of High
Resistance.................................. 7
4.2 Measurement of Large
Inductance............................. 8
4.3 Partial Substitution
Methods........................................ 8
4.4 Series Substitution
Methods.............................................. 9
4.5 Series Resistance
Method..............................................10
4.6 Parallel Resistance
Method..............................................10
Section 5.0 OTHER
USES...............................................................11
5.1 Voltage
Limits.....................................................................11
5.2 Frequency
Range...............................................................11
5.3 Measurement of
Dielectrics........................................12
5.4 Measurement of Direct
Capacitance.............................13
5.5 Guard
Electrodes...............................................................14
5.6 Polarizing
Voltage...............................................................15
Section 6.0
CONSTRUCTION....................................................15
6.1 Electrical
Circuit...............................................................15
6.2
Adjustments..........................................................................15
-
GR-8256-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics