Informacje o sprzęcie

IFR FM/AM-1200A Communications Service Monitor
Producent:
IFR
Modelu: FM/AM-1200A
Data: 1986
Kategorii: Radiokomunikacja
Grupa: Communications Service Monitor
Opis:
Informacje:
                                    The FM/AM- 1200S/A is a processor controlled, digitally
synthesized FM/AM/SSB receiver and generator, with an
integral oscilloscope/ spectrum analyzer. The receiver is a
triple conversion superheterodyne receiver capable of
receiving signals from 250 kHz to 999 .9999 MHz.

The signal generator is capable of producing modulated or
unmodulated RF signals from 250 kHz to 999.9999 MHz. A
function generator will produce six functions with ranges
from 10 Hz up to 10 kHz and one function up to 30 kHz. A
duplex generator can produce a signal up to ±49.99 MHz from
the received frequency. The oscilloscope and spectrum
analyzer on the FM/AM-1200S utilize a common CRT. Bandwidth
of the oscilloscope is DC to 1 MHz and the dynamic range of
the spectrum analyzer on the FM/AM-1200S is from -30 dBm to
-100 dBm.

Te Podręczniki są dostępne dla powyższego urządzenia:

Typ instrukcji: Instrukcja serwisowa IFR-5359-Manual-Page-1-Picture
Stron: 491
Rozmiar: 17.94 Mbytes (18810177 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer:
Data: 15 maj 1987
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: 3cd1618e1726c951b5cbf79481b542e7
Pliki do pobrania: 626 od 19 styczeń 2014
Informacje:
This manual contains maintenance instructions for the
FM/AM-1200S and FM/AM-1200A Communications Service Monitors.
The information in this manual will enable the technician to:	

1. Service, test, repair or replace any major assembly or
module within the test set.

2 . Maintain the operating condition of the set to expected
performance standards.

3. Understand the principles of operation as they relate to
the overall operation of the set as well as to individual
circuits.

The contents of this manual are divided into seven major
sections:

SECTION 1 - INTRODUCTION

Provides a brief description of the electrical and
mechanical configuration of the FM/AM-1200S/A, intended to
familiarize the technician with the overall structure of the
set.

SECTION 2 - THEORY OF OPERATION

Describes the FM/AM-1200S/A circuit theory on three levels
of complexity, a simplified overview, a functional theory of
interactive modules, and a detailed theory of each module.
Appropriate block diagrams accompany each discussion.

SECTION 3 - PERFORMANCE EVALUATION

Contains "covers on" functional checkout procedures for
evaluating the performance of the FM/AM-1200S/A in each of
its modes of operation and major functi ons.

SECTION 4 - CALIBRATION

Contains step-by-step calibration procedures for use at
normal calibration intervals or after ma king repairs or
replacements.

SECTION 5 - PREVENTIVE MAINTENANCE

Contains routine instructions for cleaning and inspection of
the FM/AM-12 OOS/A.

SECTION 6 - PC BOARD ASSEMBLI ES/CIRCUIT SCHEMATICS

Contains component layout drawings for all mechanical
assemblies, PC Board assemblies, interconnect diagrams,
circuit schematics, waveforms and charts reflecting voltage
levels keyed to test points.

SECTION 7 - ILLUSTRATED PARTS CATALOG

Contains information for identification, requisition and
issuance of replacement parts for the FM/AM-1200S and
FM/AM-1200A Communications Service monitor.

APPENDICES


IFR-5359-Manual-Page-1-Picture


Typ instrukcji: Instrukcja obsługi IFR-5360-Manual-Page-1-Picture
Stron: 292
Rozmiar: 5.47 Mbytes (5734034 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer: 1002-5501-000
Data: 1988
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: d538961f011e341944c311e3eedefd95
Pliki do pobrania: 380 od 19 styczeń 2014
Informacje:
This manual contains instructions for operating the F
M/AM-1200S/A Communications Service Monitor. The instruction
level of this manual is relatively basic and presupposes no
previous experience on the part of the operator with a
communication service monitor of this type. A basic
understanding, however, of comm uni cation electronics and
practical troubleshooting methods will be helpful. It is
strongly recommended that operator be thoroughly familiar
with Sections 1 through 3 of this manual before attempting
to perform any operating procedures contained in Section 4.

IFR-5360-Manual-Page-1-Picture


Typ instrukcji: Instrukcja obsługi IFR-6782-Manual-Page-1-Picture
Stron: 282
Rozmiar: 9.46 Mbytes (9915762 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer:
Data: 01 wrzesień 1991
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: 2a057f3aacadc7a9fdb8725e80829b76
Pliki do pobrania: 393 od 25 maj 2015
Informacje:
This manual contai ns Instructions for operat i ng the
FM/AM-1200S/A Communications Service Monitor. The
instruction level of this manual i relatively basic and
presupposes no previous experience' on the part of the
operator with a communication service monitor of this type.
A basi understand!ng, however, of communication electronics
and practical troubleshooting methods will be helpful. It is
strongly recommended that operator be thoroughly familiar
with Sections 1 through 3 of this manual before attempting
to perform any operating procedures contained in Section 4.
APPLICABILITY
All information contained in this manual applies to both the
FM/AM-1200 and FM/AM-1200A models, except where otherwise
noted. For reasons of brevity, whenever text information is
applicable to both models, the units are referenced as
11FM/AM- 1200S/A" (instead of FM/AM- 1200S and FM/AM-1200A
separately).
ORGANIZATION
The operation manual is divided into the following major
sections: SECTION 1 - INTRODUCTION
Provides a brief intro du c t i on to the F M/AM-1200S/A
including pur pose, functional capabilities and uses.
SECTION 2 - INSTALLATION
Provides a step-by-step procedure for setting up the FM/AM-
1200S/A for operation.
SECTION 3 - DESCRIPTION OF CONTROLS, CONNECTORS & INDICATORS
Identifies and functionally describes all FM/AM-1200S/A
controls connectors and indieat or s.
SECTION
4 - OPERATION
Contains instructions for operating the FM/AM-1200S/A
Keyboard and VFD. Using the Keyboard, the operator can enter
data into the FM/AM-1200S/A in the following modes:
1.
Direct Data Entry
2,
Programmed Data Entry into Memory
3.
Executed Data Entry from Memory
In addition to
Keyboard operation, this section contains a selection of
basic operating procedures pertaining to all major functions
of the FM/AM-1200S/A.
SECTION 5 - AVAILABLE OPTIONS
Contains descriptions and operating procedures of available
options to the FM/AM- 1200S/A.
Useful supplementary information relating to the operation
of the FM/AM-1200S/A is contained in appendices at the rear
of the manual. (See Table of Contents for a detailed list of
manual contents.)
IFR-6782-Manual-Page-1-Picture


Typ instrukcji: Instrukcja obsługi IFR-7006-Manual-Page-1-Picture
Stron: 0
Rozmiar: 9.46 Mbytes (9915762 Bytes)
Język: Angielski
Zmiana:
Podręcznik numer:
Data:
Jakość: Skanowany dokument, wszystko czytelne.
Data wysłania:
MD5: ce38d51d567d9ce4bd0906c5ef2eb96f
Pliki do pobrania: 226 od 08 sierpień 2015
Informacje:
This manual contains Instructions for operating the
FM/AM-1200S/A Communications Service Monitor. The
instruction level of this manual is relatively basic and
presupposes no previous experience' on the part of the
operator with a communication service monitor of this type.
A basic understanding, however, of communication electronics
and practical troubleshooting methods will be helpful. It is
strongly recommended that operator be thoroughly familiar
with Sections 1 through 3 of this manual before attempting
to perform any operating procedures contained in Section 4.