Apparatuur informatie

Ulco Medical Signet 615 Systeem voor verdoving
Fabrikant:
Ulco Medical
Model: Signet 615
Datum: 2005
Categorie: Medische en biomedische apparatuur
Groep: Systeem voor verdoving
Beschrijving: Anaesthesia Workstation
Informatie:
                                    The Signet 615 Anaesthesia Machine is an apparatus for
providing continuous gas inhalation anaesthesia for
human adults and children (above 5kg body weight).

All working surfaces are designed to be easy to clean and
front wheels are lockable to prevent unwanted movement
A monitor shelf is available as an option.
An aluminium accessory rail is fitted to the sides of the
working area for easy attachment of many options
The absorber post can be mounted either on the left or right
hand sides or both, allowing the absorber to be swapped from
side to side
Internally mounted mains outlets used to power options

Deze handboeken zijn beschikbaar voor de bovengenoemde apparatuur:

Manueel de Type: Gebruikershandleiding Ulco-10284-Manual-Page-1-Picture
Pagina 's: 30
Grootte: 995.17 Kbytes (1019054 Bytes)
Taal: Engels
Herziening: 1.2
Handleiding-ID/Number: SG6-UM-001
Datum: 01 januari 2005
Kwaliteit: Elektronisch document, geen scan, zeer goed leesbaar.
Uploaden datum:
MD5: 3d7fe6d485643f108efe31ef7a8883e0
Downloads: 17 Sinds 10 februari 2018
Informatie:
Warranty Statement
.......................................................................................6
About this manual
..........................................................................................6
Intended
Use..................................................................................................6
Device
Classification......................................................................................7
Background....................................................................................................7
Major features
................................................................................................7
1.6.1
 Overall strengths
.................................................................................7
1.6.2
 Typical configuration
...........................................................................7
Safety
Precautions.........................................................................................8
1.7.1
 Powering the unit up for the first time
..................................................8
1.7.2
 Follow the Instructions for Use
............................................................8
1.7.3
 Liability for proper function or damage
................................................8
1.7.4
 Maintenance and Repairs
...................................................................8
1.7.5
 Use of anaesthetic
agents...................................................................8
1.7.6
 Power Connection
...............................................................................8
1.7.7
 Monitoring and
alarms.........................................................................9
Gas
controls.................................................................................................10
Flowmeters
..................................................................................................10
Patient Block
................................................................................................11
Vaporisers....................................................................................................11
Ventilator......................................................................................................12
Soda-lime
absorber......................................................................................12
The anti-hypoxic device
...............................................................................12
Gas
manifold................................................................................................12
Main regulators
............................................................................................13
Second stage
regulators...........................................................................13
Pressure gauges
......................................................................................13
Scavenging...............................................................................................13
Auxiliary oxygen
outlet..............................................................................13
Pipeline hose assemblies
.........................................................................13
2.15
 Patient
circuitry.........................................................................................14
2.15.1 The circle
circuit...............................................................................14
2.16
 Oxygen failure warning device
.................................................................14
2.17
 Auxiliary Power Outlets
............................................................................14
2.18
 Other accessories
....................................................................................15
2.18.1 Accessory power
.............................................................................15
Protocol for checking the Anaesthetic Machine
...........................................16
3.2
 Operational checklist procedure – pre testing
..............................................19
3.2.1
 Visual examination
............................................................................19
3.2.2
 General preparation – pre
check.......................................................20
3.2.3
 Cylinder Fitting
..................................................................................20
3.2.4
 Component integrity
..........................................................................20
3.2.5
 General
.............................................................................................20
4.1
 Medical Gas
Mixing......................................................................................21
4.1.1
 Accuracy and the Effects of
Backpressure........................................21
4.2
 Circle Systems
.............................................................................................21
4.3
 Troubleshooting
...........................................................................................21
4.3.1
 Leaks.................................................................................................21
5.1
 Cleaning.......................................................................................................23
5.2
 Disinfecting
..................................................................................................23
5.3
 Steam Autoclaving
.......................................................................................23
5.4
 Filters
...........................................................................................................23
6.1
 Service intervals and service components for Signet ‘615’
..........................24
7.1
 Physical........................................................................................................25
7.2
 Electromagnetic
Compatibility......................................................................25
7.2.1
 Electromagnetic Emissions
...............................................................25
7.2.2
 Electromagnetic Immunity
.................................................................25
7.2.3
 Recommended Separation
Distance.................................................26
7.2.4
 Recommended Separation Distances from Portable and Mobile RF
Communication Equipment
...........................................................................27
7.3
 Symbols
.......................................................................................................27
7.4
 Standard
items.............................................................................................28
7.5
 Optional
Items..............................................................................................28

Ulco-10284-Manual-Page-1-Picture


Manueel de Type: Servicehandboek Ulco-10287-Manual-Page-1-Picture
Pagina 's: 65
Grootte: 5.33 Mbytes (5589585 Bytes)
Taal: Engels
Herziening: 1.4
Handleiding-ID/Number: SG6-UM-002
Datum: 01 januari 2005
Kwaliteit: Elektronisch document, geen scan, zeer goed leesbaar.
Uploaden datum:
MD5: 6b0994bf908e9939c7daefab38b55a78
Downloads: 17 Sinds 10 februari 2018
Informatie:
This manual provides information for the preparation,
assembly and maintenance of the Signet 615 anaesthesia
machine, together with suitable equipment from the Ulco
range. Although this equipment has been carefully
designed for simplicity of assembly and use, it is
recommended that the contents of this manual be studied before
attempting preparation or maintenance of the equipment.
Explanatory diagrams are provided in order to help the
reader understand the concepts described.
This service manual should be read in conjunction with the
Signet 615 user manual and the manual(s) for the
vaporisers and ventilator (if attached).
Ulco-10287-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics