Attrezzatura informazioni:

Hickok Electrical Instrument Company 244 Alimentazione
Produttore:
Hickok Electrical Instrument Company
Modello: 244
Data:
Categoria: Strumenti di misura
Gruppo: Alimentazione
Descrizione: Mobil/Comm DC Power Supply
Informazioni:
                                    DESCRIPTION

The Hickok Model 244 Mobil/Comm Power Supply is a compact,
state-of-the-art, precision instrument, designed to supply
filtered, regulated, direct current, applicable to
servicing automotive-type electronic equipment, specifically
personal communications transceivers such as Citizen Band
units.

Model 244 incorporates features of particular value
to the communication equipment technician. The voltage
output is variable from 10 to 14.5 Vdc with a calibrated
meter designation for 13.8 Vdc. The current output
is capable of supplying 0 to 3 amperes. Both voltage
and current are metered. "Foldback" current limiting
makes the Model 244 absolutely burn-out proof. Even a
dead short across any output terminals will cause no
damage. There are no circuit breakers to reset, or fuses
to replace. After the short circuit is removed, the
 unit will return to normal operation. During shorted
or high current conditions, the "foldback" current limit
circuit reduces available current to approximately 1.4
amperes and the OVERLOAD indicator lamp lights. Three 5-way
output binding-post terminals are provided on the
front panel, +, -, and ground. Depending on the application,
the unit may be operated up to 500 volts off ground potential.

Questi manuali sono disponibili per la macchina in oggetto:

Hickok Electrical Instrument Company -- 244 -- Servizio e manuale utente
Nome file: Hickok-3865-Manual-Page-1-Picture
Tipo manuale: Servizio e manuale utente
Pagine: 22
Dimensioni: 15.77 Mbytes (16534186 Bytes)
Lingua: inglese
Revisione:
Manual-ID/Number: 2490-678
Data:
Qualità: Documento scansionato, tutto leggibile.
Data di caricamento:
MD5: e50a774ec47e649c0434b5499b706fec
ed2kID: 36083a587311d1b40ebf68bd4c762d5a
Download: 126 da 07 January 2013
Informazioni:
TABLE OF CONTENTS
SECTION	Page

I	GENERAL INFORMATION ................1

Description..........................1

Specifications..........................2

Controls and Indicators Description..........3

II	OPERATION............................5

General ............................5

Preliminary Operation....................5

Operation............................5

Using Model 244 to Power Automotive . .	6 Radio Equipment

Using Model 244 with Output Referenced . .	6 to Ground

III	APPLICATIONS..........................7

Testing Citizen Band Transceivers............7

IV	THEORY OF OPERATION..................8

General..............................8

Regulator............................8

Overload Condition......................8

Overload Protection ....................8

Metering............................9

V	MAINTENANCE ........................10

General..............................10

VI	CALIBRATION..........................11

General ............................11

Equipment Required..................11

Preliminary..........................11

Maximum Output Voltage Adjustment ...	12

Panel Meter Voltage Calibration..........12

Panel Meter Current Calibration..........12

Foldback Current-Limiting Calibration ...	13

VII	PARTS LIST............................14
Hickok-3865-Manual-Page-1-Picture
Inizio Free Download


Commenti

Ancora nessun commento.

Aggiungi commento

* Richiesto
(non sarà pubblicata)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Type the numbers for four hundred seventy-two.
 
Inserire la risposta:
 
Comunicami i nuovi commenti via e-mail.
 
Ricordami su questo computer.
 
 
Powered by Commentics