Equipment information

Quadtech Inc. Sentry 20 Plus Analyzer
Manufacturer:
Model:
Sentry 20 Plus
Date:
2005
Category:
Group:
Description:
Hipot Tester

Information

The Sentry Plus Series is available in three models, the 10, 20 and 30, all of which provide AC Hipot testing capability. Additionally, the Sentry 20 & 30 Plus instruments provide DC Hipot testing. The Sentry 30 Plus unit provides Insulation Resistance testing. The hipot test can be programmed over a voltage range of 0.05 to 5kV AC and 0.05 to 6kV DC with a min/max leakage current detection range of 0.001 to 20mA AC and 0.0001 to 5mA DC. Insulation resistance measurements are possible to 50GΩ at programmable DC test voltages between 50 and 1000V. Each instrument comes standard with programmable ground continuity, internal storage containing 60 memory locations (10 steps each) and a remote Interface with start/stop inputs & pass/fail outputs. UL Requirements The Sentry Plus Series instruments meet the requirements outlined by UL for Hipot Testers. The Sentry Plus indicates the test potential (test voltage), has both visual and audible indication of failure and the STOP switch must be manually pressed prior to another measurement being made. The Sentry Plus Series instrument has a 100VA output [(5000V * 20mA) = 100VA]. The Sentry Plus Series instrument also measures and displays the output voltage directly at the output terminals during the test.

show more

User Manual
Manual Type:
User Manual
Pages:
85
Size:
360.01 Kbytes (368649 Bytes)
Language:
english
Revision:
Manual-ID:
150697/A4
Date:
2005 01 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 01 29
MD5:
528365f705357bffc44ad0435fbd65d6
Downloads:
2679

Information

Warranty ... 5 Specifications ... 7 Accessories ... 11 Safety Precautions ... 13 Condensed Operating Instructions ... 15 Introduction - Section 1 1.1 Unpacking and Inspection ... 21 1.2 Product Overview ... 21 1.3 Controls and Indicators ... 22 1.3.1 Front Panel Controls and Indicators ... 22 1.3.2 Rear Panel Controls and Connectors ... 23 1.4 Installation ... 24 1.4.1 Dimensions ... 24 1.4.2 Instrument Positioning ... 24 1.4.3 Power Requirements ... 24 1.4.4 Safety Inspection ... 25 Operation - Section 2 2.1 Terms and Conventions ... 27 2.2 Start-Up ... 31 2.3 Programming Electrical Safety Tests ... 31 2.4 Programming a Ground Continuity Test ... 35 2.5 Programming an AC Hipot Test ... 37 2.6 Programming a DC Hipot Test ... 39 2.7 Programming an Insulation Resistance (IR) Test ... 41 2.8 Programming a Pause (PA) in Test Sequence ... 43 2.9 Storing a Test Setup ... 45 2.10 Programming a Multi-Step Test ... 47 2.11 PRESET Test Parameters ... 48 2.11.1 AC-V FREQ ... 48 2.11.2 Software AGC ... 48 2.11.3 WV AUTO RANGE ... 48 2.11.4 IR AUTO RANGE ... 49 2.11.5 GFI ... 49 2.11.6 FAIL RESTART ... 49 2.12 Instrument Offset ... 50 2.13 Connection To Device Under Test ... 53 2.14 Measurement Procedure ... 54 2.15 MENU Parameters ... 56 2.15.1 MEMORY Function ... 57 2.15.2 SYSTEM Function ... 59 2.15.2.1 CONTRAST ... 59 2.15.2.2 BUZZER VOLUME ... 59 2.15.2.3 EN 50191 ... 59 2.15.2.4 DC 50V AGC ... 60 2.15.3 OPTION Function ... 60 2.15.4 CALIBRATION Function ... 60 2.15.5 KEY LOCK Function ... 61 2.15.6 CHANGE PASSWORD Function ... 63 2.15.7 ERROR LOG Function ... 65 2.15.8 ABOUT Function ... 65 Interface - Section 3 3.1 Remote ... 67 3.2 G16 International Power Strip ... 70 3.3 S07 Power Entry Adapter Cable ... 71 3.4 S03 Corded Product Adapter ... 72 3.5 S05 Foot Switch ... 73 3.6 S08 Gun Probe ... 74 3.7 S50 Plus Ground Bond Tester ... 75 Service & Calibration - Section 4 4.1 General ... 77 4.2 Instrument Return ... 77 4.3 Calibration ... 77 4.3.1 Calibration Parameters ... 78 4.3.2 Enable Calibration ... 79 4.3.3 AC Voltage Calibration ... 80 4.3.4 DC Voltage Calibration ... 80 4.3.5 IR Voltage Calibration ... 81 4.3.6 AC Current Calibration ... 82 4.3.7 DC Current Calibration ... 83 4.3.8 ARC Calibration ... 84 4.3.9 IR Resistor Calibration ... 84 4.3.10 Ground Continuity Calibration ... 85 4.3.11 Contrast Calibration ... 85 4.3.12 Finalize Calibration ... 85

show more