Disortion Analyzer
Information
The Hewlett-Packard Models 333A and 334A Distortion
Analyzers are solid state instruments for measuring
distortion and ac voltages. The Models 333A and 334A include
two control loops that automatically tune both legs of a
bridge circuit which rejects the fundamental when the
rejection circuit is initially set within the range of the
loops. A high impedance detector which operates from 500 Kc
to greater than 65 Mc provides the capability” of monitoring
the distortion of the amplitude modulation on an rf carrier.
1-3. Distortion levels of O. 1% to 1OO% full scale are
measured in seven ranges for any fundamental frequency of 5
cps to 600 Kc. Harmonics are indicated up to 3Mc. The high
sensitivity of these instruments requires only O. 3 v rms
for the 100% set level reference. The distortion
characteristics can be monitored at the OUTPUT connectors
with an oscilloscope, a true rms voltmeter, or a wave
analyzer. The instruments are capable of an isolation
voltage of 400 volts above chassis ground.
1-4. The voltmeter can be used separately for general
purpose voltage and gain measurements. It has a frequency
range of 5 cps to 3 Mc (20 cps to 500 Kc for 300 pv range)
and a voltage range of 300 pv to 300 v rms full scale.
1-5. The AM detector included in the Model 334A is a
broadband dc restoring peak detector consisting of a
semiconductor diode and Filter circuit. AM distortion levels
as low as O. 3% can be measured on a 3 v to 8 v rms carrier
modulated 30% in the standard broadcast
band, and lower than 1% distortion can be measured at the
same level of the carrier up to 65 Mc.
Manual Type:
Service and User Manual
Pages:
86
Size:
4.41 Mbytes (4626393 Bytes)
Language:
english
Revision:
Manual-ID:
00333-90005
Date:
1971 10 01
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
2017 12 30
MD5:
a077194363feaef64ea611d11ad41d3b
Downloads:
791
Manual Type:
Datasheet
Pages:
2
Size:
262.77 Kbytes (269078 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
2020 05 31
MD5:
a0b79211593ae364b71af83403a18a94
Downloads:
662
Manual Type:
Service and User Manual
Pages:
53
Size:
1.30 Mbytes (1359297 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
2015 05 31
MD5:
a71965357f184688c02a2e6c75db4cb1
Downloads:
902
Information
This manual includes installation and operation instructions
and covers operator’s, organizational, direct support (DS),
general support (GS), and depot maintenance. It describes
Hewlett-Packard (Federal support Code 80537) Distortion
Analyzer Models 333A and 334A (fig. l-l). A basic issue
items list for this equipment is not included as part of
this manual.