Informations sur l'appareil:

Fluke PM3390B Oscilloscopes
Fabricant:
Fluke
Modèle: PM3390B
Date: 1998
Catégorie: Mètres
Groupe: Oscilloscopes
Description: Autoranging Combiscobe Instrument
Information:
                                    There are five models in this family of FLUKE oscilloscopes. Each of these
models is a combination of an analog real-time oscilloscope and a fully featured
digital storage oscilloscope. By pressing a single key, you can switch the
instrument from the analog mode to the digital mode and back. This allows each
of the units to be used in an optimum operating mode for all kinds of signal
conditions. Complex data streams, modulated waveforms, and video signals can
often best be seen in the analog mode of operation. The digital mode of operation
is more suited for single events, signals with low repetition frequencies, and when
automatic measurements need to be performed.
In this family there is a choice of five models. Two models have a bandwidth of
200 MHz, two have a bandwidth of 100 MHz and one has a bandwidth of 60 MHz.
Beside the 2 channel models with EXT TRIG input, there is a choice of two models
with four fully featured channels, all shown in the following table:

Type Number   Bandwidth    Sample rate  Number of Channels    Input Impedance
PM3370B       60MHz        200Ms/s         2                    1MΩ    
PM3380B       100MHz       200Ms/s         2                    1MΩ
PM3384B       100MHz       200Ms/s         4                    1MΩ
PM3390B       200MHz       200Ms/s         2                    1MΩ/50Ω
PM3394B       200MHz       200Ms/s         4                    1MΩ/50Ω

In the same instrument family, there are two 200-MHz and two 100-MHz analog
oscilloscopes that have specifications similar to the above-mentioned analog/
digital combination oscilloscopes operating in analog mode.
All analog/digital combination oscilloscopes listed above have the following features:
- Autoranging attenuators.
- Realtime clock.
- 32K sample acquisition memory in 4 channel versions.
- 8K sample acquisition memory, expandable to 32K in 2 channel versions.
- Up to 40 waveforms stored in memory or 204 waveforms with optional
   memory extension.
- Autoset function for an instant optimized signal display at the touch of a button.
- Autoranging timebase.
- Cursor measurements with 1% accuracies.
- Extensive set of fully automated voltmeter and time measurement functions.
- Probe operated ’Touch Hold and Measure’ function freezes the display and
  instantly displays the signal frequency, amplitude and dc voltage level.
- Peak detection for the capture of glitches as narrow as 5 ns.
- Pattern, State and Glitch triggering (2 ns) (2 channel models; 4ns Glitch
  triggering only)
- Event delay and pretriggering and posttriggering.
- TV triggering including HDTV and TV line selection.
- Serial interface for printing and plotting.
- Averaging to reduce signal noise and to increase the vertical resolution from
  8 to 16 bits.
- Advanced mathematics, including digital low-pass filtering. A Math+ option
  adds integration, differentiation, histogramming, and FFT.
- Sine interpolation and magnification which enables true to life four channel
  single shot acquisitions with a timebase up to 625 ns/div (32x magnified)
- A delayed timebase with full trigger features.
- An RS-232 (EIA-232-D) interface (standard) and an GPIB/IEEE-488 interface
  (optional).
- Autocal for automatic fine tuning of all circuitry to achieve maximum accuracy
  under all user conditions.
- Closed case calibration for efficient maintenance of traceable calibration at
  minimum cost.

The following options are available:
- A MATH+ option with more automated measurement functions including
  envelope and measurement pass/fail testing. Also included in this option are
  Integration, Differentiation, Histogramming, and FFT.
- Memory extension offering 32K acquisition length and the ability to store 156
  traces (of 512 samples each) in memory for 2 channel versions.
- IEEE-488.2 interface using the new SCPI (Standard Commands for
  Programmable Instruments) industry standard for remote control of test and
  measurement equipment.

Les guides suivants sont disponibles pour l'équipement ci-dessus:

Fluke -- PM3390B -- Manuel de l'utilisateur
Nom du fichier: Fluke-4115-Manual-Page-1-Picture
Type de document: Manuel de l'utilisateur
Nombre de pages: 297
Taille du fichier: 2.68 Mbytes (2807171 Bytes)
langue: anglaise
Révision:
Document ID/Numéro:
Date: November 1998
qualité: Électronique de documents, numérisation sans, bien lisible.
Chargé sur:
MD5: cfed27e7fba150e25ea4a12de4294e74
ed2kID: 67b0deca469accbca6ae5acb1a966df0
Téléchargements: 769 depuis 03 February 2013
Information:
Fluke-4115-Manual-Page-1-Picture
Télécharger maintenant gratuit


Fluke -- PM3390B -- Manuel de l'utilisateur
Nom du fichier: Fluke-6753-Manual-Page-1-Picture
Type de document: Manuel de l'utilisateur
Nombre de pages: 297
Taille du fichier: 1.06 Mbytes (1106568 Bytes)
langue: anglaise
Révision:
Document ID/Numéro:
Date: 02 November 1998
qualité: Document scanné, très bien lisible.
Chargé sur:
MD5: 3f219bd3094107aaedb76228a8b39105
ed2kID: 1016cf6716177e735bf4d11f92df1000
Téléchargements: 134 depuis 19 May 2015
Information:
The SCPI Programming Manual for the CombiScope™ instruments
describes how to program your CombiScope™ instrument via the
IEEE bus using SCPI commands.
1.1 What this Manual Contains
A complete table of contents is given at the beginning of
the manual.
Chapter 1 ABOUT THIS MANUAL
Explains what the SCPI programming manual for the
CombiScopes instruments contains.
Chapter 2 GETTING STARTED WITH SCPI PROGRAMMING
Tells you how to get started quickly with your CombiScope
instrument. You can execute the program examples per
(sub)section or from the beginning until the end.
Chapter 3 USING THE COMBISCOPE INSTRUMENTS
Explains how SCPI works for your CombiScope instrument from
the functional point of view. Section 3.1 is an introduction
and section 3.2 explains the fundamental programming
concepts. The other sections and subsections represent the
functional use of your CombiScope instrument.
Chapter 4 COMMAND REFERENCE
Is a complete alphabetical reference of all implemented SCPI
commands. In the beginning a command summary is given to
provide you with a quick reference.
Appendix A
Appendix B
Appendix C
Appendix D
Appendix E
APPLICATION PROGRAM EXAMPLES
Appendix A describes some application program examples. The
application programs are supplied on floppy.
CROSS REFERENCES
Appendix B gives cross references between SCPI commands and
front panel keys, softkey menu options, and instrument
functions.
MANUAL CONVENTIONS
Appendix C explains which abbreviations and symbols are used
in the manual. It also gives a list of the tables, figures,
and documents referenced.
STANDARDS INFORMATION
Appendix D gives information regarding SCPI and IEEE-488.2
standards.
SUMMARY OF SYSTEM SETTINGS
Appendix E lists the system settings per functional group
(node), plus the applicable instrument settings per node.
A full alphabetical index is given at the end of the manual.
Fluke-6753-Manual-Page-1-Picture
Télécharger maintenant gratuit


Commentaires

Pas encore de commentaires.

Ajouter un Commentaire

* Informations obligatoires
(ne sera pas publiée)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Which word in this sentence is bold?
 
Entrez la réponse:
 
Avertissez-moi des nouveaux commentaires par e-mail.
 
Se souvenir de moi sur cet ordinateur.
 
 
Powered by Commentics