Equipment information

Advantest Corporation TR 4120A Oscilloscope
Manufacturer:
Model:
TR 4120A
Date:
1989
Category:
Group:
Description:

Information

TR4120A is a tracking scope having the following performance: 100Hz to 30MHz Max. 10Hz Max. -135dBV 80dB Measurement range Resolution Input sensitivity Dynamic range Furthermore, since TR4120A includes a tracking generator, it directly reads and analyzes the frequency characteristics in addition to analyzing the spectrum. Also, connecting an ADVANTEST frequency Counter to this device provides a function to read the frequency on the marker point at an accuracy specified by the frequency Counter. This tracking Generator is operated as a selective Amplifier (or tuned Amplifier.) Using this function, some weak signal is selected and amplified. The ON-AIR signal can be measured at an accuracy specified by the carrier frequency Counter.

show more

User Manual
Manual Type:
User Manual
Pages:
69
Size:
1.15 Mbytes (1200776 Bytes)
Language:
english
Revision:
Manual-ID:
0EB00 9005
Date:
1989 01 01
Quality:
Scanned document, all readable.
Upload date:
2017 08 26
MD5:
483c9f617468a07dbfc636f3577c6a63
Downloads:
526

Information

1 . GENERAL INFORMATION ... 1 - 1 'I . 1 General ... 1 " 1 1 .2 Check of Attachments ... 1 - 2 1.3 Storage ... 1 - 3 2. SPECIFICATIONS ... 2 - 1 2.1 Spectrum Analyzer ... 2 - 1 2.2 Tracking Generator ... 2 - 3 3. OPERATING INSTRUCTIONS ... 3 - 1 3.1 General Preparation and Precautions Prior to Use ... 3 - 1 3.2 Panel Description ... 3 - 2 3.3 Level Calibration ... 3 - 8 3.4 Use as a spectrum Analyzer ... 3 - 10 3.5 Use as a Frequency Response Direct Observation Device ... 3-12 3.6 Frequency Measurement ... 3 - 14 3.7 Adjustment of CRT Display ... 3 - 16 4. PRINCIPLES OF OPERATION ... 4 - 1 4.1 Introduction ... 4 - 1 4.2 Spectrum Analyzer Section ... 4 - 2 4.3 Tracking Generator Section ... 4 - 3 4.4 RF Section (PV059) ... 4 - 4 4.5 1st LOCAL (PF021 ) ... 4 - 5 4.6 T. G. Section (PF020) ... 4 - 6 4.7 RAMP and WARNING Section (PF022) ... 4 - 7 4.8 LC Filter Section (PK009) ... 4 - 8 4.9 Crystal Filter Section (PK008) ... 4 - 9 4.10 LOG. AMP. Section (PH066) ... 4 - 10 5. MAINTENANCE ... 5 - 1 5.1 Introduction ... 5 - 1 5.2 Test Equipment Required in Maintenance ... 5 - 2 5.3 Connection Diagram ... 5 - 3 5.4 RF Section ... 5 - 4 5.5 1st LOCAL Adjustment ... 5 - 6 5.6 T. G. Section Adjustment ... 5 - 7 5.7 LC Filter Adjustment ... 5 - 9 5.8 Crystal Filter Adjustment ... 5 - 11 5.9 Adjustment of LOG. AMP. Section (PH066) ... 5 - 12 5.10 Adjustment of RAMP GEN. Section (PF022) ... 5 - 1 4

show more