Equipment information

Fluke 8024B Digital multimeter
Manufacturer:
Model:
8024B
Date:
1981
Category:
Group:
Description:
pocket-size digital multimeter

Information

Your John Fluke Model 8024B is a pocket-size digital multimeter that is ideally suited for application in the field, laboratory, shop, or home. Some of the features of your instrument are: FUNCTIONS: All standard VOM measurement functions — ac/dc voltage, ac/dc current, resistance — plus: Conductance: A new multimeter function that allows fast, accurate, noise-free resistance measurements up to 10,000 Mil. Temperature: Used with a K-type thermocouple, this function provides direct display in degrees Celsius for K-type thermocouples. Peak-Hold: Provides short-term memory for capturing the peak value of transient ac or dc signals such as motor starting current. Continuity: Provides an immediate visual and audible indication when continuity is detected (use for passive circuit testing). Level Detector: Senses logic levels and other active signals less than 250V dc or ac rras. Visual and audible indications of the results are provided. RANGE for each function has: Full autopolarity Overrange indication Effective protection from overloads Dual slope integration measurement technique to ensure noise-free measurements OPERATOR CONVENIENCE: 3 I/2-digit liquid crystal display: A high contrast display that can be easily read from across the room. No more worries about bent needles, parallax, etc. Long term calibration stability: 2 years. Easy calibration - few adjustments. Lightweight: .482 kg (17 ounces). Safety Designed Test Leads: Finger guards on the Probe and shrouded contacts on connectors reduce the chance of accidental contact with circuit voltages. POWER: Up to 100 hours of continuous operation can be expected from a single, inexpensive, 9-volt, alkaline battery (transistor radio/'calculator type). Low battery voltage is automatically detected and displayed. The low battery indication, BT. appears in the display when about 10 hours of operation remain. Line operation is possible using a Model A81 Battery Eliminator.

show more

Service and User Manual
Manual Type:
Service and User Manual
Pages:
114
Size:
7.06 Mbytes (7400695 Bytes)
Language:
english
Revision:
2
Manual-ID:
616052
Date:
Quality:
Scanned document, all readable.
Upload date:
2016 01 27
MD5:
3c4e6630b2bb3461ccdb39bca3391149
Downloads:
996

Information

1 INTRODUCTION AND SPECIFICATIONS 1-1 l-l. INTRODUCTION ... l-l 1-3. SPECIFICATIONS ... I-I 2 OPERATING INSTRUCTIONS ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. PREPARING FOR OPERATION ... 2-I 2-4. Unpacking ... 2-1 2-7. Battery or Fuse Installation/Replacement ... 2-1 2-9. PHYSICAL FEATURES ... 2-3 2-11. OPERATING NOTES ... 2-6 2-13. Input Overload Protection ... 2-6 2-15. Input Connection to COMMON ... 2-6 2-17. Fuse Check ... 2-7 2-I9. Fuse Replacement ... 2-7 2-21. The Display ... 2-8 2-26. OPERATION ... 2-9 2-28. AC/DC Volts (V) Operation ... 2-9 2-30. AC/DC Current (mA) Operation ... 2-9 2-32. Resistance (Ω) Operation ... 2-9 2-34. Continuity Testing ... 2-13 2-36. Diode Testing ... 2-I3 2-38. Conductance (S) Operation ... 2-13 2-40. Temperature (°C) Operation ... 2-13 2-43. Level Detector Operation ... 2-16 2-45. Peak Hold Operation ... 2-17 2-47. INITIAL CHECK-OUT PROCEDURE ... 2-19 2-49. MEASUREMENT TECHNIQUES ... 2-21 2-51. Temperature Conversion ... 2-21 2-53. Conductance-to-Resistance Conversion ... 2-24 2-55. AC Measurements ... 2-24 2-57. AC/DC/Voltage Measurements ... 2-24 2-64. Resistance Measurements ... 2-27 2-67. APPLICATIONS ... 2-29 2-69. THERMOCOUPLES ... 2-29 2-70. Introduction ... 2-29 2-73. Monitoring More Than One Thermocouple ... 2-31 2-75. Leakage Tester ... 2-31 3 THEORY OF OPERATION ... 4-1 3-I. INTRODUCTION ... 3-I 3-3. OVERALL FUNCTIONAL DESCRIPTION ... 3-I 3-5. A/D Converter ... 3-1 3-I4. Voltage Measurement Function ... 3-6 3-16. Current Measurement Function ... 3-6 3-I8. Temperature (°C) Measurement Function ... 3-6 3-20. Resistance Measurement Function ... 3-6 3-23. Conductance Measurement Function ... 3-11 3-25. Peak Hold Circuit Level ... 3-11 3-27. Level Detector Circuit ... 3-11 4 MAINTENANCE ... 3-1 4-I. INTRODUCTION ... 4-I 4-3. SERVICE INFORMATION ... 4-I 4-7. GENERAL INFORMATION ... 4-3 4-8. Access Information ... 4-3 4-17. Cleaning ... 4-5 4-19. Battery/Backup Fuse Replacement ... 4-6 4-21. PERFORMANCE TEST ... 4-6 4-23. Initial Procedure ... 4-6 4-25. Display Test ... 4-7 4-27. Voltage Test ... 4-8 4-29. Current Test ... 4-8 4-3I. Resistance/Conductance Test ... 4-8 4-33. Peak Hold Test ... 4-11 4-35. Continuity Test ... 4-11 4-37. Level Detector Test ... 4-12 4-39. BT Test ... 4-12 4-4I. Temperature Test ... 4-14 4-43. CALIBRATION ADJUSTMENTS ... 4-I4 4-46. TROUBLESHOOTING ... 4-15 5 LIST OF REPLACEABLE PARTS ... 5-1 5-I. INTRODUCTION ... 5-I 5-4. HOW TO OBTAIN PARTS ... 5-2 6 Accessories INFORMATION ... 6-1 6-!. INTRODUCTION ... 6-1 6-3. DELUXE CARRYING CASE (C90) ... 6-1 6-5. RUGGED CARRYING CASE (Y8105) ... 6-I 6-8. Introduction ... 6-1 6-10. Specifications ... 6-4 6-11. TYPE K. BEAD THERMOCOUPLE (Y8I03) ... 6-4 6-12. Introduction ... 6-4 6-14. Specifications ... 6-4 6-15. THERMOCOUPLE TERMINATION (Y8104) ... 6-4 6-17. TEMPERATURE PROBES (80T-I50C and 80T-I50F) . 6-5 6-18. Introduction ... 6-5 6-20. Specifications ... 6-5 6-21. HIGH VOLTAGE Probe (80K.-6) ... 6-5 6-22. Introduction ... 6-5 6-24. Specifications ... 6-5 6-25. HIGH VOLTAGE Probe (80K-40) ... 6-5 6-26. Introduction ... 6-5 6-28. Specifications ... 6-6 6-29. HIGH FREQUENCY Probe (83RF) ... 6-6 6-30. Introduction ... 6-6 6-32. Specifications ... 6-6 6-33. HIGH FREQUENCY Probe (85RF) ... 6-6 6-34. Introduction ... 6-6 6-36. Specifications ... 6*7 6-37. CURRENT TRANSFORMER (801-600) ... 6-7 6-38. Introduction ... 6-7 6-40. Specifications ... 6-7 6-41. CURRENT SHUNT (80J-I0) ... 6-7 6-42. Introduction ... 6-7 6-44. Specifications ... 6-7 6-45. BATTERY ELIMINATOR (A8I) ... 6-8 6-47. AC/DC CURRENT Probe (Y8I00) ... 6-8 6-48. Introduction ... 6-8 6-50. Specifications ... 6-8 6-51. AC CURRENT TRANSFORMER (Y8I01) ... 6-9 6-52. Introduction ... 6-9 6-54. Specifications ... 6-9 6-55. SAFETY DESIGNED TEST LEAD SET (TI.M ) ... 6-9 6-57. DELUXE TEST LEAD SET (Y8I34) ... 6-10 6-59. SLIM FLEX TEST LEAD SET (Y8140) ... 6-10 7 SCHEMATIC DIAGRAMS ... 7-1 A MANUAL STATUS INFORMATION ... A-1

show more

Service and User Manual
Manual Type:
Service and User Manual
Pages:
59
Size:
2.97 Mbytes (3110462 Bytes)
Language:
english
Revision:
1
Manual-ID:
616052
Date:
Quality:
Scanned document, all readable.
Upload date:
2016 02 13
MD5:
79c3969ab5d6ac7bcff7b40421e4442a
Downloads:
773

Information

1 INTRODUCTION AND SPECIFICATIONS .. ... 1-1 1-3. INTRODUCTION ... !-! 1-3. SPECIFICATIONS ... 1-1 2 OPERATING INSTRUCTIONS ... ... 2-1 2-1. INTRODUCTION ... ... 2-1 2-3, PREPARING FOR OPERATION ... ... 2-1 2-4. Unpacking ... ... 2-1 2-7. Battery or Fuse Installation/Replacement ... ... 2-i 2-9. PHYSICAL FEATURES ... ... 2-3 2-11. OPERATING NOTES ... ... 2-6 2-13. Input Overload Protection ... ... 2-6 2-15. Input Connection to COMMON ... ... 2-6 2-17. Fuse Check ... ... 2-7 2-19. Fuse Replacement ... ... 2-7 2-21. The Display ... ... 2-8 2-26. OPERATION ... ... 2-9 2-28. AC/DC Volts (V) Operation ... ... 2-9 2-30. AC/DC Current (mA) Operation ... ... 2-9 2-32. Resistance (f2) Operation ... ... 2-9 2-34. Continuity Testing ... ... 2-13 2-36. Diode Testing ... ... 2-13 2-38. Conductance (S) Operation ... ... 2-13 2-40. Temperature (°C) Operation ... ... 2-13 2-43. Level Detector Operation . t ... ... 2-16 2-45. Peak Hold Operation ... ... 2-17 2-47. INITIAL CHECK-OUT PROCEDURE ... ... 2-19 2-49. MEASUREMENT TECHNIQUES ... ... 2-2! 2-51. Temperature Conversion ... ... 2-21 2-53. Conductance-to-Resistance Conversion ... ... 2-24 2-55. AC Measurements ... ... 2-24 2-57. AC/DC/Voltage Measurements ... ... 2-24 2-60. AC/DC Current Measurements ... ... 2-24 2-64. Resistance Measurements 2-27 2-67. APPLICATIONS ... 2-29 2-69. THERMOCOUPLES ... 2-29 2-70. Introduction 2-29 2-73. Monitoring More Than One Thermocouple ... 2-3! 2-75. Leakage Tester ... 2-31 3 THEORY OF OPERATION ... 4-1 3-1. INTRODUCTION ... 3-J 3-5. A/D Converter 3-J 3-I4. Voltage Measurement Function ... 3-6 3-16. Current Measurement Function ... 3-6 3-I8. Temperature (°C) Measurement Function ... 3-6 3-20. Resistance Measurement Function ... 3-6 3-23. Conductance Measurement Function ... ... 3-25. Peak Hold Circuit Level ... 3-M 3-27. Level Detector Circuit ... 3-1E 4 MAINTENANCE ... ... 3-1 4-1. INTRODUCTION ... 4-I 4-3. SERVICE INFORMATION .. 4-1 4-7. GENERAL INFORMATION ... 4-3 4-8. Access Information - 4-3 4-17. Cleaning ... 4-5 4-I9. Battery/Backup Fuse Replacement ... 4-6 4-21. PERFORMANCE TEST 4-6 4-23. Initial Procedure ... 4-6 4-25. Display lest ... 4-7 4-27. Voltage Test 4-8 4-29. Current Test ... 4-8 4-31. Resistance/Conductance 7'est ... 4-8 4-33. Peak Hold Test ... 4-11 4-35. Continuity Test 4-11 4-37. Level Detector Test 4-12 4-39. BT Test 4-12 4-41, Temperature Test ... 4-14 4-43. CALIBRATION ADJUSTMENTS ... 4-14 4-46. TROUBLESHOOTING ... 4-15 5 LIST OF REPLACEABLE PARTS 5-1 5-1. INTRODUCTION ... 5-i 5-4. HOW TO OBTAIN PARTS 5-2 6 Accessories INFORMATION ... 6-1 6-1. INTRODUCTION ... 6-! 6-3. DELUXE CARRYING CASE (C90) . . ... 6-! 6-5. RUGGED CARRYING CASE (Y8I05) ... ... 6-1 6-8. Introduction ... 6-! 6-I0. Specifications ... .. 6-4 6-11 TYPE K BEAD THERMOCOUPLE (Y8103) ... 6-4 6-12. Introduction ... 6-4 6-14. Specifications ... 6-4 6-15. THERMOCOUPLE TERMINATION <Y8f04) ... 6-4 6-17. TEMPERATURE PROBES (SOT-150C and 80T-150F) . 6-5 6-18. introduction ... 6-5 6-20. Specifications ... ... 6-5 6-22. Introduction ... 6-5 6-24. Specifications ... , ... 6-5 6-25. HIGH VOLTAGE Probe (80K-40) ... 6-5 6-26. Introduction ... 6-5 6-28. Specifications ... 6-6 6-29. HIGH FREQUENCY Probe (83RE) ... 6-6 6-30. Introduction ... 6-6 6-32. Specifications ... 6-6 6-33. HIGH FREQUENCY Probe (85RF) ... 6-6 6-34. Introduction ... 6-6 6-36. Specifications-· ... 6^-7 6-37. CURRENT TRANSFORMER (801-600) ... 6-7 6-38. Introduction ... 6-7 6-40. Specifications ... 6-7 6-4L CURRENT SHUNT (80J-10) ... 6-7 6-42. Introduction ... - ... 6-7 6-44. Specifications ... 6-7 6-45. BATTERY ELIMINATOR (A8I) ... 6-8 6-47. AC/DC CURRENT Probe (Y8100) ... 6-8 6-48. Introduction ... 6-8 6-50. Specifications ... 6-8 6-51. AC CURRENT TRANSFORMER (Y8101) ... 6-9 6-52. Introduction ... 6-9 6-54. Specifications ... 6-9 6-55. SAFETY DESIGNED TEST LEAD SET (Y8I32) ... 6-9 6-57. DELUXE TEST LEAD SET (Y8134) ... 6-10 6-59. SLIM FL.EX TEST LEAD SET {Y8140) ... 6-10 7 SCHEMATIC DIAGRAMS ... 7-1 A MANUAL CHANGE AND BACKDATING INFORMATION ... A-1

show more