Informations de l’équipement

Kikusui Electronics Corporation PAB 70-1 Compteur de fréquence
Fabricant:
Kikusui Electronics Corporation
Modèle: PAB 70-1
Date:
Catégorie: Mètres
Groupe: Compteur de fréquence
Description: REGULATED DC POWER SUPPLIES
Informations:
                                    Kikusui PAB Series Regulated DC Power Supplies are compact,
light, transistorized series regulator type, and provides
larger current rates for its sizes. The output voltage is
finely variable for a range of 0 to the rated voltage with a
10-turn potentiometer or a combination of coarse and fine
adjustment potentiometers. A voltmeter and an ammeter are
mounted on the front panel.
To guard against overload and shorting of the output
circuity PAB Series are incorporated with a
constant-current-type current limiting circuit which
operates positively. The limiting current value is
continuously variable for a range of 10$ - 100% of the rated
current, and PAB Series can be used as a constant-current
power supply.
Two units of the same model can be operated in parallel in a
one-control mode (master-slave mode) of operations thereby
doubling the output current rating.
Up to four unit can be installed on a 19-inch standard rack,
using the frame and mounting brackets which are available as
options.

Ces manuels sont disponibles pour les équipements ci-dessus :

Type manuel: Service et Manuel de l'utilisateur Kikusi-7052-Manual-Page-1-Picture
Pages: 19
Taille: 689.07 Kbytes (705605 Bytes)
Langue: Anglais
Révision:
Numéro d’identification:
Date:
Qualité: Document scanné, la lecture en partie mal, en partie illisible.
Télécharger date:
MD5: c21183316bdc440ff9b945160a8038c7
Téléchargements: 550 depuis 14 août 2015
Informations:
1. GENERAL
.......................................................................................
1
2. SPECIFICATIONS
............................................................................
2
3. EXPLANATION OP PANEL ITEMS
................................................... 4
4. OPERATION METHOD
......................................................................
7
4.1 Operation
..........................................................................
7
4.1.1 Single Operation
.................................................. 7
4.1.2 Series Operation
.................................................... 7
4.1.3 Overload Protection when in Series Operation. 8
4.1.4 Parallel Operation
............................................... 9
4.2 Conditions of Use
.......................................................... 12
4.3 Voltage Drop by Ammeter
.............................................. 12
4.4 Current Limiting Circuit
............................................ 12
5. MAINTENANCE
................................................................................
14
Schematic Circuit Diagram